Comparative Analysis of the Diagnostic Value of S-Detect Technology in Different Planes Versus the BI-RADS Classification for Breast Lesions
Academic Radiology · 2025
DOI: 10.1016/j.acra.2024.08.005 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Academic Radiology, 2025. Verfasst von Panpan Zhang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasound, The Affiliated Taizhou Hospital, Wenzhou Medical University, Linhai, Zhejiang Province, China. Hauptthemen laut MEDLINE: Breast Neoplasms, Ultrasonography, Mammary, Deep Learning, Image Interpretation, Computer-Assisted. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 28 Literaturangaben.
Abstract (Originalsprache)
RATIONALE AND OBJECTIVES: S-Detect, a deep learning-based Computer-Aided Detection system, is recognized as an important tool for diagnosing breast lesions using ultrasound imaging. However, it may exhibit inconsistent findings across multiple imaging planes. This study aims to evaluate the diagnostic performance of S-Detect in different planes and identify factors contributing to these inconsistencies. MATERIALS AND METHODS: A retrospective cohort study was conducted on 711 patients with 756 breast lesions between January 2019 and January 2022. S-Detect was utilized to assess lesions in radial and anti-radial planes. BI-RADS classifications were employed for comparative analysis. The diagnostic performance was compared within each group, and p-values were computed for intergroup comparisons. Univariable and multivariable analyses were conducted to identify factors contributing to diagnostic inconsistency in S-Detect across planes. RESULTS: Among 756 breast lesions, 668 (88.4%) exhibited consistent S-Detect outcomes across planes while 88 (11.6%) were inconsistent. In the consistent group, the diagnostic accuracy and area under the curve (AUC) of S-Detect were significantly higher than those of BI-RADS (accuracy: 91.2% vs. 84.9%, p = 0.045; AUC: 0.916 vs. 0.859, p = 0.036). In the inconsistent group, the diagnostic accuracy and AUC of S-Detect in radial and anti-radial planes were lower than those of BI-RADS (accuracy: 47.7% for radial, 52.2% for anti-radial vs. 69.3% for BI-RADS, p = 0.014, p-anti = 0.039; AUC: 0.503 for radial, 0.497 for anti-radial vs. 0.739 for BI-RADS, p = 0.042, p-anti
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ultrasound, The Affiliated Taizhou Hospital, Wenzhou Medical University, Linhai, Zhejiang Province, China.
- Department of Ultrasound, The Affiliated Taizhou Hospital, Wenzhou Medical University, Linhai, Zhejiang Province, China. Electronic address: linxf@enzemed.com.
Zitieren
APA
Zhang, P., Zhang, M., Lu, M., Jin, C., Wang, G., & Lin, X. (2025). Comparative Analysis of the Diagnostic Value of S-Detect Technology in Different Planes Versus the BI-RADS Classification for Breast Lesions. Academic Radiology. https://doi.org/10.1016/j.acra.2024.08.005
Vancouver
Zhang P, Zhang M, Lu M, Jin C, Wang G, Lin X. Comparative Analysis of the Diagnostic Value of S-Detect Technology in Different Planes Versus the BI-RADS Classification for Breast Lesions. Academic Radiology. 2025. doi:10.1016/j.acra.2024.08.005
BibTeX
@article{Zhang2025,
author = {Zhang, Panpan and Zhang, Min and Lu, Menglin and Jin, Chaoying and Wang, Gang and Lin, Xianfang},
title = {Comparative Analysis of the Diagnostic Value of S-Detect Technology in Different Planes Versus the BI-RADS Classification for Breast Lesions},
journal = {Academic Radiology},
year = {2025},
doi = {10.1016/j.acra.2024.08.005}
}
EUVIMED