Performance of GPT-4 on the American College of Radiology In-training Examination: Evaluating Accuracy, Model Drift, and Fine-tuning
Academic Radiology · 2024
DOI: 10.1016/j.acra.2024.04.006 ↗Kurz gefasst
Fachartikel in der Zeitschrift Academic Radiology, 2024. Verfasst von David L Payne und 8 weiteren Autor:innen. Beteiligte Einrichtung: Stony Brook University Hospital Department of Radiology, 101 Nicolls Road, Stony Brook, New York 11794, USA (D.L.P., K.P., W.M.B., K.C., M.H., M.M., …. Hauptthemen laut MEDLINE: Radiology, Educational Measurement, Clinical Competence, Internship and Residency. Die Arbeit wurde bisher 34-mal zitiert (Crossref) und nennt 37 Literaturangaben.
Abstract (Originalsprache)
RATIONALE AND OBJECTIVES: In our study, we evaluate GPT-4's performance on the American College of Radiology (ACR) 2022 Diagnostic Radiology In-Training Examination (DXIT). We perform multiple experiments across time points to assess for model drift, as well as after fine-tuning to assess for differences in accuracy. MATERIALS AND METHODS: Questions were sequentially input into GPT-4 with a standardized prompt. Each answer was recorded and overall accuracy was calculated, as was logic-adjusted accuracy, and accuracy on image-based questions. This experiment was repeated several months later to assess for model drift, then again after the performance of fine-tuning to assess for changes in GPT's performance. RESULTS: GPT-4 achieved 58.5% overall accuracy, lower than the PGY-3 average (61.9%) but higher than the PGY-2 average (52.8%). Adjusted accuracy was 52.8%. GPT-4 showed significantly higher (p = 0.012) confidence for correct answers (87.1%) compared to incorrect (84.0%). Performance on image-based questions was significantly poorer (p < 0.001) at 45.4% compared to text-only questions (80.0%), with adjusted accuracy for image-based questions of 36.4%. When the questions were repeated, GPT-4 chose a different answer 25.5% of the time and there was no change in accuracy. Fine-tuning did not improve accuracy. CONCLUSION: GPT-4 performed between PGY-2 and PGY-3 levels on the 2022 DXIT, significantly poorer on image-based questions, and with large variability in answer choices across time points. Exploratory experiments in fine-tuning did not improve performance. This study underscores the potential and risks of using minimally-prompted general AI models in interpreting radiologic images as a diagnostic tool. Implementers of general AI radiology systems should exercise caution given the possibility of spurious yet confident responses.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Stony Brook University Hospital Department of Radiology, 101 Nicolls Road, Stony Brook, New York 11794, USA (D.L.P., K.P., W.M.B., K.C., M.H., M.M., M.J.); Stony Brook University Department of Biomedical Informatics, 1…
- Stony Brook University Hospital Department of Radiology, 101 Nicolls Road, Stony Brook, New York 11794, USA (D.L.P., K.P., W.M.B., K.C., M.H., M.M., M.J.).
- Stony Brook University Department of Biomedical Informatics, 1 Lauterbur Drive, Stony Brook, New York 11794, USA (D.L.P., P.P.).
- Northwestern University Feinberg School of Medicine Department of Radiology, 676 North Clair Street, Chicago, Illinois 60611, USA (V.H.).
Zitieren
APA
Payne, D. L., Purohit, K., Borrero, W. M., Chung, K., Hao, M., Mpoy, M., Jin, M., Prasanna, P., & Hill, V. (2024). Performance of GPT-4 on the American College of Radiology In-training Examination: Evaluating Accuracy, Model Drift, and Fine-tuning. Academic Radiology. https://doi.org/10.1016/j.acra.2024.04.006
Vancouver
Payne DL, Purohit K, Borrero WM, Chung K, Hao M, Mpoy M, et al. Performance of GPT-4 on the American College of Radiology In-training Examination: Evaluating Accuracy, Model Drift, and Fine-tuning. Academic Radiology. 2024. doi:10.1016/j.acra.2024.04.006
BibTeX
@article{Payne2024,
author = {Payne, David L and Purohit, Kush and Borrero, Walter Morales and Chung, Katherine and Hao, Max and Mpoy, Mutshipay and Jin, Michael and Prasanna, Prateek and Hill, Virginia},
title = {Performance of GPT-4 on the American College of Radiology In-training Examination: Evaluating Accuracy, Model Drift, and Fine-tuning},
journal = {Academic Radiology},
year = {2024},
doi = {10.1016/j.acra.2024.04.006}
}
EUVIMED