Deep Learning-Based Reconstruction Improves the Image Quality of Low-Dose CT Colonography
Academic Radiology · 2024
DOI: 10.1016/j.acra.2024.01.021 ↗Kurz gefasst
Fachartikel in der Zeitschrift Academic Radiology, 2024. Verfasst von Yanshan Chen und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, the Six Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510655, China (Y.C., Z.H., L.F., W.Z., D.K., D.Z.,…. Hauptthemen laut MEDLINE: Deep Learning, Radiation Dosage, Colonography, Computed Tomographic, Signal-To-Noise Ratio. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 33 Literaturangaben. Gefördert von: Xinjiang Uygur Autonomous Region Natural Science Foundation.
Abstract (Originalsprache)
RATIONALE AND OBJECTIVES: To evaluate the image quality of low-dose CT colonography (CTC) using deep learning-based reconstruction (DLR) compared to iterative reconstruction (IR). MATERIALS AND METHODS: Adults included in the study were divided into four groups according to body mass index (BMI). Routine-dose (RD: 120 kVp) CTC images were reconstructed with IR (RD-IR); low-dose (LD: 100kVp) images were reconstructed with IR (LD-IR) and DLR (LD-DLR). The subjective image quality was rated on a 5-point scale by two radiologists independently. The parameters for objective image quality included noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). The Friedman test was used to compare the image quality among RD-IR, LD-IR and LD-DLR. The KruskalWallis test was used to compare the results among different BMI groups. RESULTS: A total of 270 volunteers (mean age: 47.94 years ± 11.57; 115 men) were included. The effective dose of low-dose CTC was decreased by approximately 83.18% (5.18mSv ± 0.86 vs. 0.86mSv ± 0.05, P 0.05). CONCLUSION: Compared to IR, DLR provided low-dose CTC with superior image quality at an average radiation dose of 0.86mSv, which may be promising in future colorectal cancer screening.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, the Six Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510655, China (Y.C., Z.H., L.F., W.Z., D.K., D.Z., M.L.); Biomedical Innovation Center, the Sixth Affiliated Hospital, S…
- Medical Imaging Center, the First People's Hospital of Kashi Area, Kashi, Xinjiang 844000, China (G.D.).
- Department of Radiology, the Second Hospital of Shanxi Medical University, Taiyuan, Shanxi 030001, China (W.Z.).
- School of Computer Science, Qufu Normal University, Rizhao, Shandong 276826, China (Y.Z.).
Förderung
- Xinjiang Uygur Autonomous Region Natural Science Foundation
Zitieren
APA
Chen, Y., Huang, Z., Feng, L., Zou, W., Kong, D., Zhu, D., Dai, G., Zhao, W., Zhang, Y., & Luo, M. (2024). Deep Learning-Based Reconstruction Improves the Image Quality of Low-Dose CT Colonography. Academic Radiology. https://doi.org/10.1016/j.acra.2024.01.021
Vancouver
Chen Y, Huang Z, Feng L, Zou W, Kong D, Zhu D, et al. Deep Learning-Based Reconstruction Improves the Image Quality of Low-Dose CT Colonography. Academic Radiology. 2024. doi:10.1016/j.acra.2024.01.021
BibTeX
@article{Chen2024,
author = {Chen, Yanshan and Huang, Zixuan and Feng, Lijuan and Zou, Wenbin and Kong, Decan and Zhu, Dongyun and Dai, Guochao and Zhao, Weidong and Zhang, Yuanke and Luo, Mingyue},
title = {Deep Learning-Based Reconstruction Improves the Image Quality of Low-Dose CT Colonography},
journal = {Academic Radiology},
year = {2024},
doi = {10.1016/j.acra.2024.01.021}
}