Test Retest Reproducibility of Organ Volume Measurements in ADPKD Using 3D Multimodality Deep Learning
Academic Radiology · 2024-03 · 31 (3) · 889-899
DOI: 10.1016/j.acra.2023.09.009 ↗Kurz gefasst
Fachartikel in der Zeitschrift Academic Radiology, 2024-03. Verfasst von Xinzi He und 14 weiteren Autor:innen. Beteiligte Einrichtung: School of Electrical and Computer Engineering, Cornell University and Cornell Tech, New York, New York (X.H., R.S.); Department of Radiology, Weill C…. Hauptthemen laut MEDLINE: Polycystic Kidney, Autosomal Dominant, Deep Learning. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCATS NIH HHS, Shaw Family Foundation, National Science Foundation.
Abstract (Originalsprache)
RATIONALE AND OBJECTIVES: Following autosomal dominant polycystic kidney disease (ADPKD) progression by measuring organ volumes requires low measurement variability. The objective of this study is to reduce organ volume measurement variability on MRI of ADPKD patients by utilizing all pulse sequences to obtain multiple measurements which allows outlier analysis to find errors and averaging to reduce variability. MATERIALS AND METHODS: In order to make measurements on multiple pulse sequences practical, a 3D multi-modality multi-class segmentation model based on nnU-net was trained/validated using T1, T2, SSFP, DWI and CT from 413 subjects. Reproducibility was assessed with test-re-test methodology on ADPKD subjects (n = 19) scanned twice within a 3-week interval correcting outliers and averaging the measurements across all sequences. Absolute percent differences in organ volumes were compared to paired students t-test. RESULTS: Dice similarlity coefficient > 97%, Jaccard Index > 0.94, mean surface distance < 1 mm and mean Hausdorff Distance < 2 cm for all three organs and all five sequences were found on internal (n = 25), external (n = 37) and test-re-test reproducibility assessment (38 scans in 19 subjects). When averaging volumes measured from five MRI sequences, the model automatically segmented kidneys with test-re-test reproducibility (percent absolute difference between exam 1 and exam 2) of 1.3% which was better than all five expert observers. It reliably stratified ADPKD into Mayo Imaging Classification (area under the curve=100%) compared to radiologist. CONCLUSION: 3D deep learning measures organ volumes on five MRI sequences leveraging the power of outlier analysis and averaging to achieve 1.3% total kidney test-re-test reproducibility.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Electrical and Computer Engineering, Cornell University and Cornell Tech, New York, New York (X.H., R.S.); Department of Radiology, Weill Cornell Medicine, New York, New York (X.H., Z.H., H.D., D.J.R., A.S., S…
- Department of Radiology, Weill Cornell Medicine, New York, New York (X.H., Z.H., H.D., D.J.R., A.S., S.I.R., S.J.W., K.T., G.S., A.G., R.S., M.R.P.).
- Department of Medicine, Weill Cornell Medicine, New York, New York (J.M.C., D.S., J.D.B.); The Rogosin Institute, New York, New York (J.M.C., D.S., J.D.B.).
- Department of Radiology, Weill Cornell Medicine, New York, New York (X.H., Z.H., H.D., D.J.R., A.S., S.I.R., S.J.W., K.T., G.S., A.G., R.S., M.R.P.); Columbia University Vagelos College of Physicians and Surgeons, New Y…
Förderung
- NCATS NIH HHS
- Shaw Family Foundation
- National Science Foundation
- National Institutes of Health
- Department of Radiology, Weill Cornell Medical College
Zitieren
APA
He, X., Hu, Z., Dev, H., Romano, D. J., Sharbatdaran, A., Raza, S. I., Wang, S. J., Teichman, K., Shih, G., Chevalier, J. M., Shimonov, D., Blumenfeld, J. D., Goel, A., Sabuncu, M. R., & Prince, M. R. (2024). Test Retest Reproducibility of Organ Volume Measurements in ADPKD Using 3D Multimodality Deep Learning. Academic Radiology, 31(3), 889-899. https://doi.org/10.1016/j.acra.2023.09.009
Vancouver
He X, Hu Z, Dev H, Romano DJ, Sharbatdaran A, Raza SI, et al. Test Retest Reproducibility of Organ Volume Measurements in ADPKD Using 3D Multimodality Deep Learning. Academic Radiology. 2024;31(3):889-899. doi:10.1016/j.acra.2023.09.009
BibTeX
@article{He2024,
author = {He, Xinzi and Hu, Zhongxiu and Dev, Hreedi and Romano, Dominick J and Sharbatdaran, Arman and Raza, Syed I and Wang, Sophie J and Teichman, Kurt and Shih, George and Chevalier, James M and Shimonov, Daniil and Blumenfeld, Jon D and Goel, Akshay and Sabuncu, Mert R and Prince, Martin R},
title = {Test Retest Reproducibility of Organ Volume Measurements in ADPKD Using 3D Multimodality Deep Learning},
journal = {Academic Radiology},
year = {2024},
volume = {31},
number = {3},
pages = {889--899},
doi = {10.1016/j.acra.2023.09.009}
}
EUVIMED