EUVIMEDEUVIMED entdecken
Crossref

Radiologist-Trained AI Model for Identifying Suboptimal Chest-Radiographs

Giridhar Dasegowda, Bernardo C Bizzo, Reya V Gupta, Parisa Kaviani, Shadi Ebrahimian, Debra Ricciardelli, Faezeh Abedi-Tari, Nir Neumark, Subba R Digumarthy, Mannudeep K Kalra, Keith J Dreyer

Academic Radiology · 2023

DOI: 10.1016/j.acra.2023.03.006 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Academic Radiology, 2023. Verfasst von Giridhar Dasegowda und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Massachusetts General Hospital and Harvard Medical School, 75 Blossom Court, Suite 248, Boston, MA 02114; Mass General Brigh…. Hauptthemen laut MEDLINE: Lung, Radiography, Thoracic. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 15 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

RATIONALE AND OBJECTIVES: Suboptimal chest radiographs (CXR) can limit interpretation of critical findings. Radiologist-trained AI models were evaluated for differentiating suboptimal(sCXR) and optimal(oCXR) chest radiographs. MATERIALS AND METHODS: Our IRB-approved study included 3278 CXRs from adult patients (mean age 55 ± 20 years) identified from a retrospective search of CXR in radiology reports from 5 sites. A chest radiologist reviewed all CXRs for the cause of suboptimality. The de-identified CXRs were uploaded into an AI server application for training and testing 5 AI models. The training set consisted of 2202 CXRs (n = 807 oCXR; n = 1395 sCXR) while 1076 CXRs (n = 729 sCXR; n = 347 oCXR) were used for testing. Data were analyzed with the Area under the curve (AUC) for the model's ability to classify oCXR and sCXR correctly. RESULTS: For the two-class classification into sCXR or oCXR from all sites, for CXR with missing anatomy, AI had sensitivity, specificity, accuracy, and AUC of 78%, 95%, 91%, 0.87(95% CI 0.82-0.92), respectively. AI identified obscured thoracic anatomy with 91% sensitivity, 97% specificity, 95% accuracy, and 0.94 AUC (95% CI 0.90-0.97). Inadequate exposure with 90% sensitivity, 93% specificity, 92% accuracy, and AUC of 0.91 (95% CI 0.88-0.95). The presence of low lung volume was identified with 96% sensitivity, 92% specificity, 93% accuracy, and 0.94 AUC (95% CI 0.92-0.96). The sensitivity, specificity, accuracy, and AUC of AI in identifying patient rotation were 92%, 96%, 95%, and 0.94 (95% CI 0.91-0.98), respectively. CONCLUSION: The radiologist-trained AI models can accurately classify optimal and suboptimal CXRs. Such AI models at the front end of radiographic equipment can enable radiographers to repeat sCXRs when necessary.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LungRadiography, ThoracicAdultHumansMiddle AgedAgedRetrospective StudiesRadiographyRadiologists

Stichwörter der Autor:innen

Artificial IntelligenceComputer-assisted Image processingQuality improvementRadiographyThoracic Radiography

Autor:innen und Institutionen

  • Department of Radiology, Massachusetts General Hospital and Harvard Medical School, 75 Blossom Court, Suite 248, Boston, MA 02114; Mass General Brigham Data Science Office (DSO), 100 Cambridge St, Boston, MA, US 02114.
  • Department of Radiology, Massachusetts General Hospital and Harvard Medical School, 75 Blossom Court, Suite 248, Boston, MA 02114.
  • Mass General Brigham Data Science Office (DSO), 100 Cambridge St, Boston, MA, US 02114.
  • Department of Radiology, Massachusetts General Hospital and Harvard Medical School, 75 Blossom Court, Suite 248, Boston, MA 02114; Mass General Brigham Data Science Office (DSO), 100 Cambridge St, Boston, MA, US 02114.…

Zitieren

APA

Dasegowda, G., Bizzo, B. C., Gupta, R. V., Kaviani, P., Ebrahimian, S., Ricciardelli, D., Abedi-Tari, F., Neumark, N., Digumarthy, S. R., Kalra, M. K., & Dreyer, K. J. (2023). Radiologist-Trained AI Model for Identifying Suboptimal Chest-Radiographs. Academic Radiology. https://doi.org/10.1016/j.acra.2023.03.006

Vancouver

Dasegowda G, Bizzo BC, Gupta RV, Kaviani P, Ebrahimian S, Ricciardelli D, et al. Radiologist-Trained AI Model for Identifying Suboptimal Chest-Radiographs. Academic Radiology. 2023. doi:10.1016/j.acra.2023.03.006

BibTeX
@article{Dasegowda2023,
  author = {Dasegowda, Giridhar and Bizzo, Bernardo C and Gupta, Reya V and Kaviani, Parisa and Ebrahimian, Shadi and Ricciardelli, Debra and Abedi-Tari, Faezeh and Neumark, Nir and Digumarthy, Subba R and Kalra, Mannudeep K and Dreyer, Keith J},
  title = {Radiologist-Trained AI Model for Identifying Suboptimal Chest-Radiographs},
  journal = {Academic Radiology},
  year = {2023},
  doi = {10.1016/j.acra.2023.03.006}
}
Kostenlos starten →