EUVIMEDEUVIMED entdecken
Crossref

Linear Regression Modeling Based Scoring System to Reduce Benign Breast Biopsies Using Multi-parametric US with Color Doppler and SWE

Burcu Özdemir Demirci, Onur Buğdaycı, Gökhan Ertaş, Deniz E T Şanlı, Handan Kaya, Erkin Arıbal

Academic Radiology · 2023

DOI: 10.1016/j.acra.2023.01.024 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Academic Radiology, 2023. Verfasst von Burcu Özdemir Demirci und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Marmara University, Istanbul, Türkiye. Hauptthemen laut MEDLINE: Elasticity Imaging Techniques, Breast Neoplasms. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 45 Literaturangaben. Gefördert von: Marmara Üniversitesi.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

RATIONALE AND OBJECTIVES: To develop a simple ultrasound (US) based scoring system to reduce benign breast biopsies. MATERIALS AND METHODS: Women with BI-RADS 4 or 5 breast lesions underwent shear-wave elastography (SWE) imaging before biopsy. Standard US and color Doppler US (CDUS) parameters were recorded, and the size ratio (SzR=longest/shortest diameter) was calculated. Measured/calculated SWE parameters were minimum (SWVMin) and maximum (SWVMax) shear velocity, velocity heterogeneity (SWVH=SWVMax-SWVMin), velocity ratio (SWVR=SWVMin/SWVMax), and normalized SWVR (SWVRn=(SWVMax-SWVMin)/SWVMin). Linear regression analysis was performed by converting continuous parameters into categorical corresponding equivalents using decision tree analyses. Linear regression models were fitted using stepwise regression analysis and optimal coefficients for the predictors in the models were determined. A scoring model was devised from the results and validated using a different data set from another center consisting of 187 cases with BI-RADS 3, 4, and 5 lesions. RESULTS: A total of 418 lesions (238 benign, 180 malignant) were analyzed. US and CDUS parameters exhibited poor (AUC=0.592-0.696), SWE parameters exhibited poor-good (AUC=0.607-0.816) diagnostic performance in benign/malignant discrimination. Linear regression models of US+CDUS and US+SWE parameters revealed an AUC of 0.819 and 0.882, respectively. The developed scoring system could have avoided biopsy in 37.8% of benign lesions while missing 1.1% of malignant lesions. The scoring system was validated with a 100% NPV rate with a specificity of 74.6%. CONCLUSION: The linear regression model using US+SWE parameters performed better than any single parameter alone. The developed scoring method could lead to a significant decrease in benign biopsies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Elasticity Imaging TechniquesBreast NeoplasmsFemaleHumansUltrasonography, MammaryLinear ModelsSensitivity and SpecificityReproducibility of ResultsBreastBiopsyDiagnosis, Differential

Stichwörter der Autor:innen

Breast NeoplasmsDecision TreesElasticity Imaging TechniquesUltrasonography, Mammary

Autor:innen und Institutionen

  • Department of Radiology, Marmara University, Istanbul, Türkiye.
  • Department of Radiology, Marmara University, Istanbul, Türkiye. Electronic address: onur.bugdayci@marmara.edu.tr.
  • Department of Biomedical Engineering, Yeditepe University, Istanbul, Türkiye.
  • Department of Radiology, Acibadem Kozyatagi Hospital, Istanbul, Türkiye; Department of Radiology, Gaziantep University, Gaziantep, Türkiye.
  • Department of Pathology, Marmara University, Istanbul, Türkiye.
  • Department of Radiology, Marmara University, Istanbul, Türkiye; Department of Radiology, Acıbadem University Medical School, Istanbul, Türkiye.

Förderung

  • Marmara Üniversitesi

Zitieren

APA

Demirci, B. Ö., Buğdaycı, O., Ertaş, G., Şanlı, D. E. T., Kaya, H., & Arıbal, E. (2023). Linear Regression Modeling Based Scoring System to Reduce Benign Breast Biopsies Using Multi-parametric US with Color Doppler and SWE. Academic Radiology. https://doi.org/10.1016/j.acra.2023.01.024

Vancouver

Demirci BÖ, Buğdaycı O, Ertaş G, Şanlı DET, Kaya H, Arıbal E. Linear Regression Modeling Based Scoring System to Reduce Benign Breast Biopsies Using Multi-parametric US with Color Doppler and SWE. Academic Radiology. 2023. doi:10.1016/j.acra.2023.01.024

BibTeX
@article{Demirci2023,
  author = {Demirci, Burcu Özdemir and Buğdaycı, Onur and Ertaş, Gökhan and Şanlı, Deniz E T and Kaya, Handan and Arıbal, Erkin},
  title = {Linear Regression Modeling Based Scoring System to Reduce Benign Breast Biopsies Using Multi-parametric US with Color Doppler and SWE},
  journal = {Academic Radiology},
  year = {2023},
  doi = {10.1016/j.acra.2023.01.024}
}
Kostenlos starten →