Enhancing untargeted lipidomics using offline two-dimensional LC–MS and systematic evaluation of data processing tools
Analytica Chimica Acta · 2026
DOI: 10.1016/j.aca.2026.346318 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2026. Verfasst von Fernanda Sousa Monteiro und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, University of Alberta, Edmonton, Alberta, Canada. Hauptthemen laut MEDLINE: Lipidomics, Liquid Chromatography-Mass Spectrometry, Lipids. Die Arbeit nennt 48 Literaturangaben. Gefördert von: Natural Sciences and Engineering Research Council of Canada, Alberta Innovates, Genome Canada.
Abstract (Originalsprache)
Although two-dimensional liquid chromatography-mass spectrometry (2DLC-MS) has been explored to improve lipidomic coverage, its practical implementation remains limited by challenges in fractionation design and interpretation of complex datasets. Here we report an optimized offline hydrophilic interaction chromatography-reversed-phase liquid chromatography (HILIC-RPLC) 2DLC-MS workflow for untargeted lipidomics. A simplified five-fraction HILIC strategy was developed to enhance lipid class separation while maintaining practical analytical throughput. Optimization of solvent composition, mobile phases, and gradient conditions improved compatibility between chromatographic dimensions and enabled efficient fractionation prior to RPLC-MS analysis. Compared with conventional one-dimensional RPLC-MS, the proposed workflow reduced lipid co-elution and ion suppression, resulting in approximately two-fold higher lipid feature coverage in biological samples including serum, tissue, and cultured cells. Chromatographic fractionation information was further used as an orthogonal parameter to evaluate lipid annotation reliability. Using this framework, three lipidomics software platforms-MetaboScape, MS-DIAL, and LipidScreener-were systematically evaluated for processing 2DLC-MS datasets. The results reveal substantial variability among software tools and demonstrate that integrating chromatographic fractionation with data processing improves confidence in untargeted lipidomic analysis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, University of Alberta, Edmonton, Alberta, Canada.
- The Metabolomics Innovation Centre, University of Alberta, Edmonton, Alberta, Canada; Department of Biological Sciences, University of Calgary, Calgary, Alberta, Canada.
- Department of Chemistry, University of Alberta, Edmonton, Alberta, Canada; The Metabolomics Innovation Centre, University of Alberta, Edmonton, Alberta, Canada. Electronic address: Liang.Li@ualberta.ca.
Förderung
- Natural Sciences and Engineering Research Council of Canada
- Alberta Innovates
- Genome Canada
- Mitacs Inc
- Canada Foundation for Innovation
Zitieren
APA
Monteiro, F. S., Zardini Buzatto, A., & Li, L. (2026). Enhancing untargeted lipidomics using offline two-dimensional LC–MS and systematic evaluation of data processing tools. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2026.346318
Vancouver
Monteiro FS, Zardini Buzatto A, Li L. Enhancing untargeted lipidomics using offline two-dimensional LC–MS and systematic evaluation of data processing tools. Analytica Chimica Acta. 2026. doi:10.1016/j.aca.2026.346318
BibTeX
@article{Monteiro2026,
author = {Monteiro, Fernanda Sousa and Zardini Buzatto, Adriana and Li, Liang},
title = {Enhancing untargeted lipidomics using offline two-dimensional LC–MS and systematic evaluation of data processing tools},
journal = {Analytica Chimica Acta},
year = {2026},
doi = {10.1016/j.aca.2026.346318}
}
EUVIMED