pH-switched single-assay spectrophotometric determination of xanthine and hypoxanthine based on urate-mediated response modulation
Analytica Chimica Acta · 2026
DOI: 10.1016/j.aca.2026.346246 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2026. Verfasst von Javier Camacho-Aguayo und 5 weiteren Autor:innen. Beteiligte Einrichtung: Nanosensors and Bioanalytical Systems (N&SB), Department of Analytical Chemistry, Faculty of Sciences, Instituto de Nanociencia y Materiales de Aragó…. Hauptthemen laut MEDLINE: Hypoxanthine, Xanthine, Uric Acid. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Gobierno de España Ministerio de Ciencia e Innovación.
Abstract (Originalsprache)
Enzymatic assays based on oxidase/peroxidase coupling usually assume quantitative conversion of enzymatically generated hydrogen peroxide into the optical product. Here, we show that this assumption fails in the xanthine oxidase-horseradish peroxidase-Amplex Red system because urate, the final product of xanthine and hypoxanthine oxidation, is not a silent product. Urate competes with Amplex Red in the peroxidase cycle, decreasing the apparent yield of resorufin formation; for xanthine, this yield was only 0.40 ± 0.01, independently of pH. A mechanistic mathematical model was developed to relate substrate oxidation, hydrogen peroxide generation, radical reactions, and final absorbance. The model explains the reduced sensitivity observed for xanthine, the different response regimes found for hypoxanthine, and the residual urate concentration after reaction completion. This understanding was then used to design a sequential single-assay spectrophotometric method for the individual determination of xanthine and hypoxanthine, two metabolites that are commonly measured together in enzymatic freshness assays. Xanthine is quantified first at pH 6, where hypoxanthine oxidation is negligible, and hypoxanthine is subsequently determined in the same recording after increasing pH and xanthine oxidase concentration. Application to refrigerated cod extracts gave recoveries of 104 ± 13% for xanthine and 90 ± 12% for hypoxanthine, supporting the feasibility of the approach for freshness-related analysis and highlighting the broader need to consider product-driven effects in oxidase/peroxidase-coupled assays.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Nanosensors and Bioanalytical Systems (N&SB), Department of Analytical Chemistry, Faculty of Sciences, Instituto de Nanociencia y Materiales de Aragón (INMA), Universidad de Zaragoza-CSIC, Zaragoza, 50009, Spain.
- Nanosensors and Bioanalytical Systems (N&SB), Department of Analytical Chemistry, Faculty of Sciences, Instituto de Nanociencia y Materiales de Aragón (INMA), Universidad de Zaragoza-CSIC, Zaragoza, 50009, Spain. Electr…
Förderung
- Gobierno de España Ministerio de Ciencia e Innovación
Zitieren
APA
Camacho-Aguayo, J., Alcubierre, S., Albareda, J., Sanz-Vicente, I., de Marcos, S., & Galbán, J. (2026). pH-switched single-assay spectrophotometric determination of xanthine and hypoxanthine based on urate-mediated response modulation. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2026.346246
Vancouver
Camacho-Aguayo J, Alcubierre S, Albareda J, Sanz-Vicente I, de Marcos S, Galbán J. pH-switched single-assay spectrophotometric determination of xanthine and hypoxanthine based on urate-mediated response modulation. Analytica Chimica Acta. 2026. doi:10.1016/j.aca.2026.346246
BibTeX
@article{CamachoAguayo2026,
author = {Camacho-Aguayo, Javier and Alcubierre, Sonia and Albareda, Juan and Sanz-Vicente, Isabel and de Marcos, Susana and Galbán, Javier},
title = {pH-switched single-assay spectrophotometric determination of xanthine and hypoxanthine based on urate-mediated response modulation},
journal = {Analytica Chimica Acta},
year = {2026},
doi = {10.1016/j.aca.2026.346246}
}
EUVIMED