Dual-mode colorimetric and photothermal sensing platform for point-of-care testing of uric acid based on enhanced peroxidase-like activity of platinum-based nanozyme by adenosine triphosphate
Analytica Chimica Acta · 2026
DOI: 10.1016/j.aca.2026.346101 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2026. Verfasst von Xia Tong und 4 weiteren Autor:innen. Beteiligte Einrichtung: Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Third Hospital of Shanxi Medical University, Tongji Shanxi Hospital, Taiyuan, 030032, Ch…. Hauptthemen laut MEDLINE: Uric Acid, Colorimetry, Platinum, Adenosine Triphosphate. Die Arbeit nennt 48 Literaturangaben. Gefördert von: Shanxi Province Science and Technology Department.
Abstract (Originalsprache)
To break through the limitation of low peroxidase-like (POD-like) activity of conventional nanozymes at neutral pH, platinum-based nanozyme assisting with adenosine triphosphate (Pt NZ/ATP) system is prepared in this study. ATP enables to promote the stability of Pt NZ and the production of O2•- and •OH, and Pt NZ/ATP displays remarkably enhanced POD-like activity (Michaelis constant Km 0.46 mM) than only Pt NZ (Km 2.1 mM). Uric acid (UA) reacts with urate oxidase to form H2O2. Then, Pt NZ/ATP triggers the POD-like reaction to catalyze H2O2 to oxidize 2,2-azinobis(3-ethylbenzothiazoline)-6-sulfonic acid (ABTS) into ABTS•+, which shows broad absorbance spectrum in visible (obvious color change) and near-infrared (high photothermal conversion efficiency) regions. Thus, dual-mode colorimetric and photothermal platform for point-of-care testing (POCT) of UA with smartphone camera and thermometer were constructed with linear range of 1.5 to 70 μM, and limit of detection of 0.81 and 1.05 μM, respectively. The relative standard deviations were less than 9.10% and 9.90% in human serum samples, and relative errors were lower than 8.28% and 6.93% comparing to the results of biochemical detector, respectively. This work not only provides an efficient enhancement approach for nanozyme activity, but also establishes sensitive, accurate and portable dual-mode POCT platform for UA assay.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Third Hospital of Shanxi Medical University, Tongji Shanxi Hospital, Taiyuan, 030032, China.
- School of Physics and Electronic Engineering, Shanxi Normal University, Taiyuan, 030031, China. Electronic address: guojing@sxnu.edu.cn.
Förderung
- Shanxi Province Science and Technology Department
Zitieren
APA
Tong, X., Guo, J., Hu, J., Liu, S., & Li, G. (2026). Dual-mode colorimetric and photothermal sensing platform for point-of-care testing of uric acid based on enhanced peroxidase-like activity of platinum-based nanozyme by adenosine triphosphate. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2026.346101
Vancouver
Tong X, Guo J, Hu J, Liu S, Li G. Dual-mode colorimetric and photothermal sensing platform for point-of-care testing of uric acid based on enhanced peroxidase-like activity of platinum-based nanozyme by adenosine triphosphate. Analytica Chimica Acta. 2026. doi:10.1016/j.aca.2026.346101
BibTeX
@article{Tong2026,
author = {Tong, Xia and Guo, Jing and Hu, Jie and Liu, Sumiao and Li, Guozhu},
title = {Dual-mode colorimetric and photothermal sensing platform for point-of-care testing of uric acid based on enhanced peroxidase-like activity of platinum-based nanozyme by adenosine triphosphate},
journal = {Analytica Chimica Acta},
year = {2026},
doi = {10.1016/j.aca.2026.346101}
}
EUVIMED