Dual-functional SiO2@Cr2O3-C18 sorbent combining Lewis acid-base and hydrophobic interactions for the selective SPE-LC-MS/MS determination of perfluoroalkyl carboxylates in protein-rich biological matrices
Analytica Chimica Acta · 2026
DOI: 10.1016/j.aca.2026.345959 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2026. Verfasst von Mohamed Rashad und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, College of Science, Kuwait University, Sabah Al Salem University City, P.O. Box 5969, Safat, Shadadiya, 13060, Kuwait. Elect…. Hauptthemen laut MEDLINE: Fluorocarbons, Solid Phase Extraction, Silicon Dioxide, Lewis Acids. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 48 Literaturangaben. Gefördert von: Kuwait University.
Abstract (Originalsprache)
BACKGROUND: The growing concern of perfluoroalkyl substances (PFAS), or "forever chemicals," with serious health implications across the globe necessitates the development of sophisticated analytical techniques for the sensitive analysis of these compounds in biological samples. However, the critical limitations of common SPE sorbents in terms of low selectivity, poor recoveries in biological samples containing high protein content, and high susceptibility to matrix effects in the form of ion suppression have hindered the analysis of these compounds. To overcome these problems, a new dual-functional sorbent was synthesized using a novel composite material consisting of chromia nanoparticles (Cr2O3) and hydrophobic octadecyl chains (C18) on a high-surface-area silica support. RESULTS: Comprehensive characterization (FTIR, TEM, XPS, BET) confirmed uniform chromia dispersion, successful dense C18 grafting, and high structural stability. Under optimized SPE-LC-MS/MS conditions, the sorbent provided enrichment factors (194-198) for three representative perfluoroalkyl carboxylates (PFHpA, PFOA, PFDoA), yielding ultra-trace limits of detection (LOD) of 25 - 26 ng L-1. To rigorously evaluate its practical utility, the method was validated in standardized synthetic human plasma. The dual-retention mechanism successfully mitigated protein fouling and severe ion suppression, demonstrating an absolute matrix effect of 85% reduction compared to the direct injection of untreated plasma). Furthermore, the sorbent exhibited robust operational reusability (>50 extraction cycles with
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, College of Science, Kuwait University, Sabah Al Salem University City, P.O. Box 5969, Safat, Shadadiya, 13060, Kuwait. Electronic address: Mohamed.r.elnos@gmail.com.
- Department of Chemistry, College of Science, Kuwait University, Sabah Al Salem University City, P.O. Box 5969, Safat, Shadadiya, 13060, Kuwait. Electronic address: Abdullah.Alhendal@ku.edu.kw.
Förderung
- Kuwait University
Zitieren
APA
Rashad, M., & Alhendal, A. (2026). Dual-functional SiO2@Cr2O3-C18 sorbent combining Lewis acid-base and hydrophobic interactions for the selective SPE-LC-MS/MS determination of perfluoroalkyl carboxylates in protein-rich biological matrices. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2026.345959
Vancouver
Rashad M, Alhendal A. Dual-functional SiO2@Cr2O3-C18 sorbent combining Lewis acid-base and hydrophobic interactions for the selective SPE-LC-MS/MS determination of perfluoroalkyl carboxylates in protein-rich biological matrices. Analytica Chimica Acta. 2026. doi:10.1016/j.aca.2026.345959
BibTeX
@article{Rashad2026,
author = {Rashad, Mohamed and Alhendal, Abdullah},
title = {Dual-functional SiO2@Cr2O3-C18 sorbent combining Lewis acid-base and hydrophobic interactions for the selective SPE-LC-MS/MS determination of perfluoroalkyl carboxylates in protein-rich biological matrices},
journal = {Analytica Chimica Acta},
year = {2026},
doi = {10.1016/j.aca.2026.345959}
}
EUVIMED