Fachartikel in der Zeitschrift Analytica Chimica Acta, 2026-10. Verfasst von Hyun-Ah Kwon und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Civil, Urban and Environmental Engineering, Seoul National University, Seoul, 08826, Republic of Korea. Hauptthemen laut MEDLINE: Fluorocarbons, Drinking Water, Water Pollutants, Chemical, Water Purification. Die Arbeit nennt 42 Literaturangaben. Gefördert von: Korea Environmental Industry & Technology Institute, Seoul National University, Korea Resources Corporation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND Per- and polyfluoroalkyl substances (PFAS) need to be effectively monitored in drinking water treatment plants (DWTPs) to assess treatment performance and manage potential health risks. Grab sampling provides only snapshot concentrations, whereas passive sampling offers time-weighted average concentrations (CTWA). Polar organic chemical integrative samplers (POCIS) are widely used for polar contaminants, including PFAS, yet their reliability for estimating CTWA in individual DWTP processes remains unclear. RESULTS PFAS passive sampling performance was evaluated in controlled laboratory tests and a 14-day field study at a pilot-scale DWTP. CTWA values were determined using POCIS consisting of a polyethersulfone membrane and a hydrophilic-lipophilic balanced sorbent. Under controlled laboratory conditions with time-varying concentrations, passive sampling reliably captured PFAS fluctuations, while 33% of the total accumulated mass of perfluorooctanesulfonic acid was found in the membrane, highlighting the importance of whole-sampler uptake for CTWA estimation. In the field study, passive sampling generally yielded lower PFAS concentrations than grab sampling even after flow-specific sampling rates were applied to each process stage, especially in stages with elevated suspended solids and organic matter. Under DWTP conditions, 21-52% of accumulated perfluorooctanoic acid was retained in the membrane, indicating that water-matrix effects altered sampler uptake. SIGNIFICANCE POCIS provided reliable PFAS concentration estimates under controlled exposure conditions, whereas field application was influenced by water-matrix conditions. These findings identify water-matrix effects as an important source of uncertainty beyond hydrodynamic correction and highlight the need for matrix-aware interpretation of passive sampling results in fields.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

FluorocarbonsDrinking WaterWater Pollutants, ChemicalWater PurificationEnvironmental MonitoringAlkanesulfonic AcidsPolymersSulfones

Stichwörter der Autor:innen

DWTPPFASPOCISPassive samplingSampling rateWater-matrix

Substanzen

FluorocarbonsDrinking WaterWater Pollutants, Chemicalpolyether sulfoneAlkanesulfonic AcidsPolymersSulfones

Autor:innen und Institutionen

  • Department of Civil, Urban and Environmental Engineering, Seoul National University, Seoul, 08826, Republic of Korea.
  • K-water Research Institute, Korea Water Resources Corporation (K-water), Daejeon, 34045, Republic of Korea.
  • Department of Civil, Urban and Environmental Engineering, Seoul National University, Seoul, 08826, Republic of Korea; Institute of Construction and Environmental Engineering, Seoul National University, Seoul, 08826, Rep…

Förderung

  • Korea Environmental Industry & Technology Institute
  • Seoul National University
  • Korea Resources Corporation

Zitieren

APA

Kwon, H. A., Jeon, M. J., & Choi, Y. (2026). Passive sampling for PFAS in a drinking water treatment plant: Potential utility, challenges, and pathways forward. Analytica Chimica Acta, 1419, 345914. https://doi.org/10.1016/j.aca.2026.345914

Vancouver

Kwon HA, Jeon MJ, Choi Y. Passive sampling for PFAS in a drinking water treatment plant: Potential utility, challenges, and pathways forward. Analytica Chimica Acta. 2026;1419:345914. doi:10.1016/j.aca.2026.345914

BibTeX
@article{Kwon2026,
  author = {Kwon, Hyun-Ah and Jeon, Min Jung and Choi, Yongju},
  title = {Passive sampling for PFAS in a drinking water treatment plant: Potential utility, challenges, and pathways forward},
  journal = {Analytica Chimica Acta},
  year = {2026},
  volume = {1419},
  pages = {345914},
  doi = {10.1016/j.aca.2026.345914}
}
Kostenlos starten →