Self-powered electrochemical glucose sensing enabled by zirconium holmium oxide/MXene/graphene nanocomposites with integrated energy storage
Analytica Chimica Acta · 2026-09 · 1416 · 345683
DOI: 10.1016/j.aca.2026.345683 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2026-09. Verfasst von Nora Mobark Farhan und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, College of Science, Princess Nourah bint Abdulrahman University, P.O. Box 84428, Riyadh, 11671, Saudi Arabia. Hauptthemen laut MEDLINE: Graphite, Nanocomposites, Electrochemical Techniques, Zirconium. Die Arbeit nennt 71 Literaturangaben. Gefördert von: Princess Nourah bint Abdulrahman University.
Abstract (Originalsprache)
Advanced wearable electronics and self-powered diagnostic devices require electrode materials that can combine efficient energy storage with reliable biosensing. This study reports a multifunctional zirconium holmium oxide/titanium carbide MXene/graphene composite, denoted as ZrHo2O4/Ti3C2Tx MXene/graphene, synthesized by a hydrothermal method and evaluated as an electrode for hybrid supercapacitor performance and non-enzymatic glucose detection. Structural, surface, and morphological analyses confirmed the integration of crystalline ZrHo2O4 with conductive Ti3C2Tx-MXene and graphene, producing a porous and interconnected architecture favorable for charge transport and electrochemical activity. The ZrHo2O4/Ti3C2Tx MXene/graphene electrode demonstrated a specific capacity (Qs) of 315.22 C g-1. When assembled with activated carbon as a battery-type hybrid supercapacitor, the device achieved a Qs of 315.22 C g-1, an energy density of 35.94 Wh kg-1, and a power density of 1275 W kg-1, while retaining 88% of its capacity after 5000 cycles. For glucose sensing in phosphate-buffered saline, the modified electrode exhibited a linear response from 0.1 μM to 1.6 mM, a sensitivity of 5.1 μA mM-1 cm-2, and a detection limit of 0.03 μM. It also revealed a 15 s response time, selectivity against common interfering species, reproducibility, and signal stability. These results demonstrate that ZrHo2O4/Ti3C2Tx-MXene/graphene is a promising dual-function electrode for integrated energy-storage and glucose-sensing platforms in wearable and point-of-care devices.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, College of Science, Princess Nourah bint Abdulrahman University, P.O. Box 84428, Riyadh, 11671, Saudi Arabia.
- Department of Physics, Riphah International University, Campus Lahore, Lahore, Pakistan.
- Department of Physics, Sakarya University, Sakarya, Turkey.
- Department of Physics, Riphah International University, Campus Lahore, Lahore, Pakistan. Electronic address: alihamza.res47@gmail.com.
- Department of Physics, College of Science, Princess Nourah bint Abdulrahman University, P.O. Box 84428, Riyadh, 11671, Saudi Arabia.
- Department of Physics, University of Okara, Okara, Pakistan; Department of Mechanical Engineering and Renewable Energy, Technical Engineering College, The Islamic University, Najaf, Iraq.
Förderung
- Princess Nourah bint Abdulrahman University
Zitieren
APA
Farhan, N. M., Khalil, S., Al-Buriahi, M. S., Hamza Shahbaz, M. A., Tamam, N., Afzal, A. M., Kumar, A., & Mumtaz, S. (2026). Self-powered electrochemical glucose sensing enabled by zirconium holmium oxide/MXene/graphene nanocomposites with integrated energy storage. Analytica Chimica Acta, 1416, 345683. https://doi.org/10.1016/j.aca.2026.345683
Vancouver
Farhan NM, Khalil S, Al-Buriahi MS, Hamza Shahbaz MA, Tamam N, Afzal AM, et al. Self-powered electrochemical glucose sensing enabled by zirconium holmium oxide/MXene/graphene nanocomposites with integrated energy storage. Analytica Chimica Acta. 2026;1416:345683. doi:10.1016/j.aca.2026.345683
BibTeX
@article{Farhan2026,
author = {Farhan, Nora Mobark and Khalil, Saba and Al-Buriahi, M S and Hamza Shahbaz, Muhammad Ali and Tamam, Nissren and Afzal, Amir Muhammad and Kumar, Abhinav and Mumtaz, Sohail},
title = {Self-powered electrochemical glucose sensing enabled by zirconium holmium oxide/MXene/graphene nanocomposites with integrated energy storage},
journal = {Analytica Chimica Acta},
year = {2026},
volume = {1416},
pages = {345683},
doi = {10.1016/j.aca.2026.345683}
}
EUVIMED