EUVIMEDEUVIMED entdecken
Crossref

Reverse-engineered ratiometric sensor assisted by dual redox-active DNA intercalators for ultrasensitive and reliable detection of mercury(II)

Min Chen, Xianxin Liu, Sifan Wang, Xuan Zheng, Feng Gao, Qingxiang Wang

Analytica Chimica Acta · 2026-09 · 1413 · 345671

DOI: 10.1016/j.aca.2026.345671 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2026-09. Verfasst von Min Chen und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Chemical Engineering and Environmental, Fujian Provincial Key Laboratory of Modern Analytical Science and Separation Technol…. Hauptthemen laut MEDLINE: Mercury, Intercalating Agents, DNA, Electrochemical Techniques. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 44 Literaturangaben. Gefördert von: Fujian Provincial Natural Science Foundation, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND Traditional electrochemical DNA sensors for Hg2+ rely on target-induced conformational changes of Hg2+-binding DNA probes, which often suffer from limited signal output and complex probe design. To address these issues, this study introduces a novel ratiometric electrochemical DNA sensor based on a "reverse-engineering" strategy, where the signal molecule is pre-immobilized on the electrode instead of the Hg2+-binding DNA. RESULTS The double-helix DNA intercalator Nile blue (NB) with excellent redox activity was covalently grafted onto a gold electrode to generate an intense inherent signal. In addition, in a solution containing target Hg2+, the polythymine DNA modified onto gold nanoparticles (AuNP@polyT) undergoes a conformational transition to a double-helix structure via specific T-Hg2+-T chemistry. Then the AuNP@polyT-Hg2+ is captured onto the electrode surface through intercalation between NB and the Hg2+-induced DNA duplex, leading to a decrease in the NB electrochemical signal. Subsequently, another intercalator, methylene blue (MB), is adsorbed into the remaining base pair space of polyT-Hg2+, generating a new indicating signal. A ratiometric response for Hg2+ is thus achieved through the decrease in the NB signal and the increase in the MB signal. Within the Hg2+ concentration range of 0.1 nM to 100 μM, log(INB/IMB) exhibits a favorable double logarithmic linear relationship with the logarithm of Hg2+ concentration, achieving a detection limit as low as 40 pM. The sensor was successfully applied to Hg2+ analysis in actual water and tea samples. SIGNIFICANCE By combining T-Hg2+-T coordination chemistry with a dual-intercalator ratiometric readout, the proposed reverse-engineered ratiometric electrochemical sensor eliminates complex DNA probe immobilization, improves accuracy and anti-interference capability, and shows great promise for on-site monitoring of Hg2+ in environmental water and tea samples.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MercuryIntercalating AgentsDNAElectrochemical TechniquesBiosensing TechniquesWater Pollutants, ChemicalOxidation-ReductionGoldMetal NanoparticlesOxazinesElectrodesLimit of DetectionMethylene Blue

Stichwörter der Autor:innen

DNA intercalatorMethylene blueNile blueRatiometric electrochemical sensorT-Hg(2+)-T

Substanzen

MercuryIntercalating AgentsDNAGoldOxazinesNile BlueMethylene BlueWater Pollutants, Chemical

Autor:innen und Institutionen

  • Department of Chemistry, Chemical Engineering and Environmental, Fujian Provincial Key Laboratory of Modern Analytical Science and Separation Technology, Minnan Normal University, Zhangzhou, 363000, PR China.
  • Department of Chemistry, Chemical Engineering and Environmental, Fujian Provincial Key Laboratory of Modern Analytical Science and Separation Technology, Minnan Normal University, Zhangzhou, 363000, PR China. Electronic…

Förderung

  • Fujian Provincial Natural Science Foundation
  • National Natural Science Foundation of China

Zitieren

APA

Chen, M., Liu, X., Wang, S., Zheng, X., Gao, F., & Wang, Q. (2026). Reverse-engineered ratiometric sensor assisted by dual redox-active DNA intercalators for ultrasensitive and reliable detection of mercury(II). Analytica Chimica Acta, 1413, 345671. https://doi.org/10.1016/j.aca.2026.345671

Vancouver

Chen M, Liu X, Wang S, Zheng X, Gao F, Wang Q. Reverse-engineered ratiometric sensor assisted by dual redox-active DNA intercalators for ultrasensitive and reliable detection of mercury(II). Analytica Chimica Acta. 2026;1413:345671. doi:10.1016/j.aca.2026.345671

BibTeX
@article{Chen2026,
  author = {Chen, Min and Liu, Xianxin and Wang, Sifan and Zheng, Xuan and Gao, Feng and Wang, Qingxiang},
  title = {Reverse-engineered ratiometric sensor assisted by dual redox-active DNA intercalators for ultrasensitive and reliable detection of mercury(II)},
  journal = {Analytica Chimica Acta},
  year = {2026},
  volume = {1413},
  pages = {345671},
  doi = {10.1016/j.aca.2026.345671}
}
Kostenlos starten →