A 3D-Printed, pump-free, microfluidic hydride generation-capillary point discharge atomic emission spectrometer for on-site arsenic detection
Analytica Chimica Acta · 2026-08 · 1411 · 345638
DOI: 10.1016/j.aca.2026.345638 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2026-08. Verfasst von Han Yan und 4 weiteren Autor:innen. Beteiligte Einrichtung: Analytical & Testing Center, Sichuan University, Chengdu, Sichuan, 610064, China. Die Arbeit nennt 36 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
BACKGROUND Conventional atomic spectrometric techniques provide high sensitivity and accuracy for element detection, yet remain constrained by large instrument size, high gas consumption, and operational complexity. Recent advances in 3D printing technology have enabled new approaches to spectral instrument miniaturization which presents new opportunities for portable, on-site analysis. RESULTS A fully integrated, 3D-printed hydride generation-capillary point discharge atomic emission spectrometer (HG-CPD-AES) was constructed for on-site arsenic speciation analysis of environmental water samples. A monolithic unit containing the microfluidic reaction chamber, a gas-liquid separator and a coaxial capillary-tungsten electrode excitation source were fabricated by stereolithography and allows direct microsyringe injection of a tiny total sample volume of 150 μL. Hydride vapor confined by the quartz capillary enhances injection efficiency and signal stability. With a total gas flow rate of just 5 mL min-1 (less than 1/20 of a conventional system), the system achieved a limit of detection of 4 μg L-1 with a linear range of 10-3000 μg L-1. The method was validated through analysis of tap water, pond water, and hot spring water samples with 100-110% recoveries and without significant difference in comparison with those by ICP-MS. SIGNIFICANCE The cost-effective and open-source design enables rapid replication in various environments, creating a scalable and robust distributed detector platform. This approach facilitates on-site arsenic monitoring in resource-limited settings where conventional analytical infrastructure is unavailable or impractical to deploy.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Analytical & Testing Center, Sichuan University, Chengdu, Sichuan, 610064, China.
- Analytical & Testing Center, Sichuan University, Chengdu, Sichuan, 610064, China. Electronic address: tianyunfei@scu.edu.cn.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Yan, H., Xiong, Y., Li, Y., Tian, Y., & Hou, X. (2026). A 3D-Printed, pump-free, microfluidic hydride generation-capillary point discharge atomic emission spectrometer for on-site arsenic detection. Analytica Chimica Acta, 1411, 345638. https://doi.org/10.1016/j.aca.2026.345638
Vancouver
Yan H, Xiong Y, Li Y, Tian Y, Hou X. A 3D-Printed, pump-free, microfluidic hydride generation-capillary point discharge atomic emission spectrometer for on-site arsenic detection. Analytica Chimica Acta. 2026;1411:345638. doi:10.1016/j.aca.2026.345638
BibTeX
@article{Yan2026,
author = {Yan, Han and Xiong, Yanqi and Li, Yingying and Tian, Yunfei and Hou, Xiandeng},
title = {A 3D-Printed, pump-free, microfluidic hydride generation-capillary point discharge atomic emission spectrometer for on-site arsenic detection},
journal = {Analytica Chimica Acta},
year = {2026},
volume = {1411},
pages = {345638},
doi = {10.1016/j.aca.2026.345638}
}
EUVIMED