Fluorescent sensor array for rapid and accurate multiplexed pathogen identification
Analytica Chimica Acta · 2026-08 · 1411 · 345629
DOI: 10.1016/j.aca.2026.345629 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2026-08. Verfasst von Siyuan Huang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Functional Polymer Materials (Ministry of Education), Institute of Polymer Chemistry, Tianjin Key Laboratory of Functional Polymer …. Hauptthemen laut MEDLINE: Fluorescent Dyes, Bacteria. Die Arbeit nennt 55 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
BACKGROUND The challenge of antimicrobial resistance is caused by delayed and inaccurate pathogen identification. It results in the existing diagnostic methods being unable to guide the appropriate use of antibiotics. This indicates that a rapid diagnostic platform is needed in clinical conditions. Therefore, an array sensor that utilizes the mechanism of bacterial activity for rapid identification is valuable. RESULTS We developed an activity-driven fluorescent sensor array. It consists of four targeted polymeric nanoprobes, each functionalized with specific recognition motifs, including phenylboronic acid and saccharides. After incubation with bacteria, the nanoprobes produced distinct fluorescence response patterns that reflected differences in energy-dependent behavior. Six pathogens were identified with an accuracy of 96.6% in 30 min, and also discriminated between drug-sensitive and drug-resistant strains. SIGNIFICANCE Subsequent mechanism studies have demonstrated that the discriminatory ability comes from differences in receptor recognition and metabolic activity. This work presents a sensing method that focuses on the dynamic physiological absorption process. The sensor array provides a rapid and accurate tool for pathogen detection and resistance analysis, meeting the critical need in addressing antimicrobial resistance.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Key Laboratory of Functional Polymer Materials (Ministry of Education), Institute of Polymer Chemistry, Tianjin Key Laboratory of Functional Polymer Materials, College of Chemistry, Nankai University, Tianjin, 300071, C…
- Department of Integrated Traditional Chinese and Western Medicine, Shengli Oilfield Central Hospital, Dongying, Shandong, 257100, China.
- Department of Integrated Traditional Chinese and Western Medicine, Shengli Oilfield Central Hospital, Dongying, Shandong, 257100, China. Electronic address: wupeipeiabc@163.com.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Huang, S., Hu, Y., Wang, H., Wang, R., Zhou, Z., Wu, P., & Zhang, X. (2026). Fluorescent sensor array for rapid and accurate multiplexed pathogen identification. Analytica Chimica Acta, 1411, 345629. https://doi.org/10.1016/j.aca.2026.345629
Vancouver
Huang S, Hu Y, Wang H, Wang R, Zhou Z, Wu P, et al. Fluorescent sensor array for rapid and accurate multiplexed pathogen identification. Analytica Chimica Acta. 2026;1411:345629. doi:10.1016/j.aca.2026.345629
BibTeX
@article{Huang2026,
author = {Huang, Siyuan and Hu, Yuqing and Wang, Hongyu and Wang, Ruiyao and Zhou, Zhongxiang and Wu, Peipei and Zhang, Xinge},
title = {Fluorescent sensor array for rapid and accurate multiplexed pathogen identification},
journal = {Analytica Chimica Acta},
year = {2026},
volume = {1411},
pages = {345629},
doi = {10.1016/j.aca.2026.345629}
}
EUVIMED