EUVIMEDEUVIMED entdecken
Crossref

A self-calibrating dual-channel MOF-based fluorescent sensor for rapid and visual phosphate detection

Jinfeng Zhou, Hailin Qiu, Qing Zhou, Chunjie Chu, Xiaodong Zhang, Yanhong Xu

Analytica Chimica Acta · 2026-07 · 1408 · 345572

DOI: 10.1016/j.aca.2026.345572 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2026-07. Verfasst von Jinfeng Zhou und 5 weiteren Autor:innen. Beteiligte Einrichtung: College of Materials Science and Engineering, Pingdingshan University, Pingdingshan, 467000, PR China. Electronic address: zhoujf016@163.com. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 49 Literaturangaben. Gefördert von: Henan Provincial Science and Technology Research Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rapid and reliable phosphate (Pi; PO43-) sensing is of critical importance for environmental monitoring, yet remains challenging due to signal instability and limited field deployability of existing methods. Herein, we report a self-calibrating dual-channel fluorescent sensor based on a metal-organic framework (MOF), denoted as 9-AA@Eu-ZIF-8@TTA, for rapid and visual Pi detection. The sensor is rationally constructed through a modular host-guest and coordination assembly strategy, in which a Pi-insensitive blue-emissive dye (acridin-9-amine, 9-AA) is encapsulated within Eu3+-doped ZIF-8 as an internal reference, while a red-emissive Eu3+-TTA coordination complex serves as the responsive channel. Pi detection is governed by a competitive coordination mechanism, where Pi preferentially binds to Eu3+, displacing the antenna ligand TTA and selectively quenching the Eu3+-centered emission at 617 nm without affecting the reference signal. This dual-channel response enables reliable ratiometric quantification of Pi over a linear range of 0-80 μM with a detection limit of 0.48 μM and a rapid response time of 0.5 min. The sensor exhibits excellent stability over a wide pH range (3-11) and high selectivity against competing ions. Importantly, the distinct red-to-blue fluorescence transition under UV excitation allows direct visual discrimination of Pi levels, while smartphone-based RGB analysis enables instrument-free quantitative readout. Accurate Pi determination in real water samples further demonstrates the practical applicability of this sensor. This work provides a versatile MOF-based design strategy for constructing robust ratiometric fluorescent sensors through the integration of host-guest chemistry and analyte-triggered coordination interactions.

Schlagwörter

Stichwörter der Autor:innen

Metal–organic frameworksPhosphate detectionRatiometric fluorescenceVisual sensing

Autor:innen und Institutionen

  • College of Materials Science and Engineering, Pingdingshan University, Pingdingshan, 467000, PR China. Electronic address: zhoujf016@163.com.
  • Orient KOJI Limited, Tianjin, 300122, PR China.
  • Fujian Engineering Research Center of Advanced Manufacturing Technology for Fine Chemicals, College of Chemical Engineering, Fuzhou University, Fuzhou, 350116, PR China.
  • College of Materials Science and Engineering, Pingdingshan University, Pingdingshan, 467000, PR China.

Förderung

  • Henan Provincial Science and Technology Research Project

Zitieren

APA

Zhou, J., Qiu, H., Zhou, Q., Chu, C., Zhang, X., & Xu, Y. (2026). A self-calibrating dual-channel MOF-based fluorescent sensor for rapid and visual phosphate detection. Analytica Chimica Acta, 1408, 345572. https://doi.org/10.1016/j.aca.2026.345572

Vancouver

Zhou J, Qiu H, Zhou Q, Chu C, Zhang X, Xu Y. A self-calibrating dual-channel MOF-based fluorescent sensor for rapid and visual phosphate detection. Analytica Chimica Acta. 2026;1408:345572. doi:10.1016/j.aca.2026.345572

BibTeX
@article{Zhou2026,
  author = {Zhou, Jinfeng and Qiu, Hailin and Zhou, Qing and Chu, Chunjie and Zhang, Xiaodong and Xu, Yanhong},
  title = {A self-calibrating dual-channel MOF-based fluorescent sensor for rapid and visual phosphate detection},
  journal = {Analytica Chimica Acta},
  year = {2026},
  volume = {1408},
  pages = {345572},
  doi = {10.1016/j.aca.2026.345572}
}
Kostenlos starten →