EUVIMEDEUVIMED entdecken
Crossref

Microfluidic Dean-flow enhanced electrochemical detection of lead in water

Shapour Jafargholinejad, Basit Ilyas, Stephanie Gora, Pouya Rezai

Analytica Chimica Acta · 2026-07 · 1407 · 345532

DOI: 10.1016/j.aca.2026.345532 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2026-07. Verfasst von Shapour Jafargholinejad und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, York University, Toronto, ON, Canada. Die Arbeit nennt 58 Literaturangaben. Gefördert von: Natural Sciences and Engineering Research Council of Canada.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND We present a cost-effective microfluidic electrochemical sensor (MES) that operates without electrode surface modification, utilizing curved microchannels to promote efficient analyte transport and enhance electrochemical sensing via Dean flow. Despite significant progress in MESs for lead (Pb) detection, current designs often rely on complex and costly fabrication, as well as environmentally taxing surface modifications. Additionally, the use of laminar flow-based straight microchannels limits mass transport and sensor sensitivity. The present MES was fabricated using pressure-sensitive adhesive and polyethylene terephthalate sheets via laser machining. Square wave voltammetry and square wave anodic stripping voltammetry were employed to evaluate the performance of the curved-channel MES. RESULTS The sensor achieved a Pb2+ limit of detection (LOD) of 2.26 μg/L, meeting the regulatory limits set by Health Canada and the U.S. Compared to the straight-channel MES, the curved-channel design showed a 66-fold increase in sensitivity and a 75-fold reduction in LOD, attributed to enhanced analyte transport via Dean flow. Further experiments with Cadmium (Cd) in water showed Cd2+ LOD of 38.3 μg/L, showcasing the expandability of the sensor to other heavy metals. Additionally, the MES demonstrated Pb2+ selectivity in the presence of interfering ions, including Cd2+, Cu2+, Zn2+, Fe3+, and Mn2+. Real water sample analysis confirmed the sensor's practicality in complex matrices, reinforcing its utility for real-world applications. SIGNIFICANCE Results demonstrate that the proposed curved-channel MES enables reliable, modifier-free, and scalable detection of Pb2+, even in complex water matrices, offering strong potential for expansion to other heavy metals detection in water.

Schlagwörter

Stichwörter der Autor:innen

Dean flowLead detectionMicrofluidic electrochemical sensorSquare wave anodic stripping voltammetryWater monitoring

Autor:innen und Institutionen

  • Department of Mechanical Engineering, York University, Toronto, ON, Canada.
  • Department of Civil Engineering, York University, Toronto, ON, Canada.
  • Department of Mechanical Engineering, York University, Toronto, ON, Canada; Department of Mechanical Engineering, George Mason University, Fairfax, VA, USA. Electronic address: prezai@gmu.edu.

Förderung

  • Natural Sciences and Engineering Research Council of Canada

Zitieren

APA

Jafargholinejad, S., Ilyas, B., Gora, S., & Rezai, P. (2026). Microfluidic Dean-flow enhanced electrochemical detection of lead in water. Analytica Chimica Acta, 1407, 345532. https://doi.org/10.1016/j.aca.2026.345532

Vancouver

Jafargholinejad S, Ilyas B, Gora S, Rezai P. Microfluidic Dean-flow enhanced electrochemical detection of lead in water. Analytica Chimica Acta. 2026;1407:345532. doi:10.1016/j.aca.2026.345532

BibTeX
@article{Jafargholinejad2026,
  author = {Jafargholinejad, Shapour and Ilyas, Basit and Gora, Stephanie and Rezai, Pouya},
  title = {Microfluidic Dean-flow enhanced electrochemical detection of lead in water},
  journal = {Analytica Chimica Acta},
  year = {2026},
  volume = {1407},
  pages = {345532},
  doi = {10.1016/j.aca.2026.345532}
}
Kostenlos starten →