Sensitivity-improved nanozyme LFIA with optimized fluid control on centrifugal microfluidic platform
Analytica Chimica Acta · 2026
DOI: 10.1016/j.aca.2026.345506 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2026. Verfasst von Lei Wang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Microfluidic Chip Development in Biomedical Engineering, School of Information Science and Technology, Beijing University of Chemical Te…. Hauptthemen laut MEDLINE: Microfluidic Analytical Techniques, Lab-On-A-Chip Devices. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 65 Literaturangaben. Gefördert von: National Natural Science Foundation of China, National Key Research and Development Program of China.
Abstract (Originalsprache)
Due to the inflexible manual operation, the sensitivity of the nanozyme-based lateral flow immunoassay (LFIA) can be potentially limited by incontrollable chromatography, insufficient utilization of sample or reagent, and suboptimal binding efficiency. Here, we present a centrifugal microfluidic platform to improve the sensitivity of nanozyme LFIA with multiple strategies to not only automate the entire assay but also to achieve more thorough reaction at each step. Two different pneumatic siphon valves without hydrophilic treatment are developed to facilitate homogeneous mixing and controllable discharging for both sample and chromogenic substrate based on two different deceleration conditions, respectively. In the first step, sustained, smooth and slow sample delivery to the strip is achieved to allow size-controllable sample loading without sacrificing the consistence of chromatograph. In the second step, to increase the reaction time of the chromogenic substrate, the chip is kept centrifuging in chromatograph process to slow down the lateral flow speed for more efficient reaction. Moreover, the chip design is further optimized to reduce the unexpected sample or reagent loss inside the chip. The performance of the developed system is systematically evaluated, and improved detection sensitivity is achieved based on comprehensive optimization, which is beneficial to POC diagnosis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Microfluidic Chip Development in Biomedical Engineering, School of Information Science and Technology, Beijing University of Chemical Technology, Beijing, 100029, China.
- CAS Engineering Laboratory for Nanozyme, Institute of Biophysics, Chinese Academic of Science, Beijing, 100101, China.
- CAS Engineering Laboratory for Nanozyme, Institute of Biophysics, Chinese Academic of Science, Beijing, 100101, China. Electronic address: gaolizeng@ibp.ac.cn.
- Institute of Microfluidic Chip Development in Biomedical Engineering, School of Information Science and Technology, Beijing University of Chemical Technology, Beijing, 100029, China. Electronic address: miaogj@mail.buct…
Förderung
- National Natural Science Foundation of China
- National Key Research and Development Program of China
Zitieren
APA
Wang, L., Zhou, J., Chen, H., Zhang, H., Liu, L., Zhang, L., Qiu, X., Gao, L., & Miao, G. (2026). Sensitivity-improved nanozyme LFIA with optimized fluid control on centrifugal microfluidic platform. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2026.345506
Vancouver
Wang L, Zhou J, Chen H, Zhang H, Liu L, Zhang L, et al. Sensitivity-improved nanozyme LFIA with optimized fluid control on centrifugal microfluidic platform. Analytica Chimica Acta. 2026. doi:10.1016/j.aca.2026.345506
BibTeX
@article{Wang2026,
author = {Wang, Lei and Zhou, Jiaxi and Chen, Hao and Zhang, Hanxing and Liu, Lingxuan and Zhang, Lulu and Qiu, Xianbo and Gao, Lizeng and Miao, Guijun},
title = {Sensitivity-improved nanozyme LFIA with optimized fluid control on centrifugal microfluidic platform},
journal = {Analytica Chimica Acta},
year = {2026},
doi = {10.1016/j.aca.2026.345506}
}
EUVIMED