EUVIMEDEUVIMED entdecken
Crossref

Integrating DNA tetrahedron with affinity magnetic levitation for selective capture and sensitive detection of circulating tumor cells

Zilong Zhang, Sidi Cun, Yuxuan Yuan, Yujin Lin, Yitao Cao, Yinzi Chen, Jing Zhang, Jing Wang, Xinfeng Zhao

Analytica Chimica Acta · 2026-07 · 1406 · 345493

DOI: 10.1016/j.aca.2026.345493 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2026-07. Verfasst von Zilong Zhang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Resource Biology and Biotechnology in Western China, Ministry of Education, College of Life Sciences, Northwest University, Xi'an, …. Hauptthemen laut MEDLINE: Neoplastic Cells, Circulating, Aptamers, Nucleotide, DNA, Cell Separation. Die Arbeit nennt 45 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Circulating tumor cell (CTC) is an evidenced biomarker for early cancer diagnosis and assessment of treatment response. This necessitates increasing attempt to develop new method for detection of CTCs with highly enriching and anti-interference capacity. Herein, we built a simple platform for CTC detection by combining aptamer-mediated specific recognition with affinity magnetic levitation (Maglev). The method involved modification of DNA tetrahedron (TDN) using SYL3C aptamer as tentacles, assembly of aptamer conjugated-TDN on microsphere by azide-alkyne click chemistry, enrichment of CTCs by the activated microspheres, and detection of CTCs by affinity Maglev. These yielded an aptamer sensor resembling octopus tentacles to enhance the capture selectivity and efficiency of CTCs. Once CTCs were captured, a microsphere@TDN@CTCs complex was formed, resulting in a change in the overall density. The number of CTCs was calculated by measuring the levitation height difference between microspheres pro- and post-binding of CTCs in affinity Maglev. An example study on MCF-7 cells exhibited a detection of 8.81 cells mL-1 in buffer solution, with repeatability characterized by a relative standard deviation of less than 4.48%, in comparison to 9.08 cell mL-1 in mimic clinical sample with a relative standard deviation of 6.98%. Analysis of mimic clinical samples demonstrated that the method was effective for the specific detection of CTCs with robust resistance to interference from co-existing substances in plasma. It is possible to serve as an early diagnostic alternative for clinically relevant cancers once large number of clinical trials are performed.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Neoplastic Cells, CirculatingAptamers, NucleotideDNACell SeparationHumansMCF-7 CellsDNA NanostructuresMicrospheresMagneticsMagnetic PhenomenaLimit of Detection

Stichwörter der Autor:innen

Affinity magnetic levitationAptamerCirculating tumor cellsDNA tetrahedron

Substanzen

Aptamers, NucleotideDNA

Autor:innen und Institutionen

  • Key Laboratory of Resource Biology and Biotechnology in Western China, Ministry of Education, College of Life Sciences, Northwest University, Xi'an, Shaanxi, 710069, China.
  • Key Laboratory of Continental Evolution and Early Life, Shaanxi Key Laboratory of Early Life and Environment, Department of Geology, Northwest University, Xi'an, Shaanxi, 710069, China.
  • Key Laboratory of Resource Biology and Biotechnology in Western China, Ministry of Education, College of Life Sciences, Northwest University, Xi'an, Shaanxi, 710069, China. Electronic address: waangjing@nwu.edu.cn.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Zhang, Z., Cun, S., Yuan, Y., Lin, Y., Cao, Y., Chen, Y., Zhang, J., Wang, J., & Zhao, X. (2026). Integrating DNA tetrahedron with affinity magnetic levitation for selective capture and sensitive detection of circulating tumor cells. Analytica Chimica Acta, 1406, 345493. https://doi.org/10.1016/j.aca.2026.345493

Vancouver

Zhang Z, Cun S, Yuan Y, Lin Y, Cao Y, Chen Y, et al. Integrating DNA tetrahedron with affinity magnetic levitation for selective capture and sensitive detection of circulating tumor cells. Analytica Chimica Acta. 2026;1406:345493. doi:10.1016/j.aca.2026.345493

BibTeX
@article{Zhang2026,
  author = {Zhang, Zilong and Cun, Sidi and Yuan, Yuxuan and Lin, Yujin and Cao, Yitao and Chen, Yinzi and Zhang, Jing and Wang, Jing and Zhao, Xinfeng},
  title = {Integrating DNA tetrahedron with affinity magnetic levitation for selective capture and sensitive detection of circulating tumor cells},
  journal = {Analytica Chimica Acta},
  year = {2026},
  volume = {1406},
  pages = {345493},
  doi = {10.1016/j.aca.2026.345493}
}
Kostenlos starten →