Z-scheme WO3/CdS heterojunction-synergized molecularly imprinted photoelectrochemical sensor for ultrasensitive and highly selective detection of gentamicin

Ruiying Zhang, Jingli Shen, Xiaosi Sang, Xinyi Dao, Dan Lu, Lingqi Kong, Qiue Cao

Analytica Chimica Acta · 2026-07 · 1407 · 345491

DOI: 10.1016/j.aca.2026.345491 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2026-07. Verfasst von Ruiying Zhang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Medicinal Chemistry for Natural Resource of Yunnan University, Ministry of Education, School of Chemical Science and Technology, Yu…. Hauptthemen laut MEDLINE: Oxides, Molecular Imprinting, Sulfides, Electrochemical Techniques. Die Arbeit nennt 57 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND Gentamicin (GEN) residues in food pose notable health hazards, including nephrotoxicity and ototoxicity, so developing trace detection methods with high sensitivity and selectivity is urgently required in the field of food safety. Conventional GEN detection approaches such as chromatography and immunosensing have inherent limitations like high cost or complex operation, and single-semiconductor photoelectrochemical (PEC) sensors face insufficient charge separation issues. This work addresses the critical need for developing a high-performance PEC sensing platform that combines superior photoelectric conversion capability with specific molecular recognition. RESULTS A Z-scheme WO3/CdS heterojunction with excellent PEC properties was utilized to develop a novel molecularly imprinted photoelectrochemical sensor (MIP-PECS) for ultrasensitive and highly selective detection of GEN. The bandgap-matched Z-scheme heterojunction serves as a crucial strategy for high-efficiency photoelectrodes. Its built-in electric field (BEF) effectively enhances directional charge separation and significantly suppresses photogenerated carrier recombination relative to single-semiconductor counterparts, while retaining strong redox activities that outperform conventional type-II heterojunctions. A polypyrrole-based molecularly imprinted polymer film (PPy-MIPF) with GEN as template molecule and pyrrole (Py) as functional monomer improves selectivity. The sensor exhibits a low detection limit of 48.4 pmol/L, a wide linear range of 0.0001-100 μmol/L, an imprinting factor (IF) of 9.96, strong anti-interference capability, superior stability and reproducibility, and satisfactory recoveries of 93.2-108.3% in milk and honey samples. SIGNIFICANCE This study concludes that the developed MIP-PECS integrates the Z-scheme WO3/CdS heterojunction and PPy-MIPF to achieve excellent balanced PEC performance and selectivity. Combining simple operation and low cost, it overcomes conventional detection method limitations, providing a practical and promising platform for reliable antibiotic detection in food quality monitoring, environmental control and related fields.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

OxidesMolecular ImprintingSulfidesElectrochemical TechniquesTungstenGentamicinsCadmium CompoundsAnti-Bacterial AgentsLimit of DetectionPhotochemical ProcessesPolymersAnimalsHoney

Stichwörter der Autor:innen

GentamicinMolecularly imprinted polymer filmPhotoelectrochemical sensorPolypyrroleZ-Scheme WO(3)/CdS heterojunction

Substanzen

OxidesSulfidestungsten oxideTungstenGentamicinscadmium sulfideCadmium CompoundsPolymersAnti-Bacterial Agents

Autor:innen und Institutionen

  • Key Laboratory of Medicinal Chemistry for Natural Resource of Yunnan University, Ministry of Education, School of Chemical Science and Technology, Yunnan University, Kunming, 650091, PR China.
  • Key Laboratory of Medicinal Chemistry for Natural Resource of Yunnan University, Ministry of Education, School of Chemical Science and Technology, Yunnan University, Kunming, 650091, PR China. Electronic address: lingqi…
  • Key Laboratory of Medicinal Chemistry for Natural Resource of Yunnan University, Ministry of Education, School of Chemical Science and Technology, Yunnan University, Kunming, 650091, PR China. Electronic address: qecao@…

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Zhang, R., Shen, J., Sang, X., Dao, X., Lu, D., Kong, L., & Cao, Q. (2026). Z-scheme WO3/CdS heterojunction-synergized molecularly imprinted photoelectrochemical sensor for ultrasensitive and highly selective detection of gentamicin. Analytica Chimica Acta, 1407, 345491. https://doi.org/10.1016/j.aca.2026.345491

Vancouver

Zhang R, Shen J, Sang X, Dao X, Lu D, Kong L, et al. Z-scheme WO3/CdS heterojunction-synergized molecularly imprinted photoelectrochemical sensor for ultrasensitive and highly selective detection of gentamicin. Analytica Chimica Acta. 2026;1407:345491. doi:10.1016/j.aca.2026.345491

BibTeX
@article{Zhang2026,
  author = {Zhang, Ruiying and Shen, Jingli and Sang, Xiaosi and Dao, Xinyi and Lu, Dan and Kong, Lingqi and Cao, Qiue},
  title = {Z-scheme WO3/CdS heterojunction-synergized molecularly imprinted photoelectrochemical sensor for ultrasensitive and highly selective detection of gentamicin},
  journal = {Analytica Chimica Acta},
  year = {2026},
  volume = {1407},
  pages = {345491},
  doi = {10.1016/j.aca.2026.345491}
}
Kostenlos starten →