EUVIMEDEUVIMED entdecken
Crossref

Ligand-engineered hollow Fe-NC nanozymes with enhanced peroxidase activity for smartphone-based point-of-care testing of isoniazid

Xinyue Zhou, Yu Zhang, Tongxin Sun, Xu Xu, Lei Zhang

Analytica Chimica Acta · 2026-07 · 1405 · 345483

DOI: 10.1016/j.aca.2026.345483 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2026-07. Verfasst von Xinyue Zhou und 4 weiteren Autor:innen. Beteiligte Einrichtung: College of Chemistry, Liaoning University, Shenyang, 110036, China. Hauptthemen laut MEDLINE: Isoniazid, Smartphone, Point-of-Care Testing, Antitubercular Agents. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 50 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Therapeutic drug monitoring of isoniazid (INH), a first-line antitubercular agent, is critical due to its narrow therapeutic window and risk of toxicity or resistance at nonoptimal concentrations. Current methods lack the simplicity and accessibility required for point-of-care testing (POCT), especially in resource-limited settings. Herein, we report a paper-based colorimetric biosensing platform that integrates hollow-structured Fe-NC (Iron-Nitrogen-Carbon) nanozymes with smartphone-assisted readout for rapid, sensitive, and selective detection of INH in human biofluids. The nanozyme is synthesized via controlled pyrolysis of a dual-linker zeolitic imidazolate/tetrazolate framework (ZTF), where 2-methylimidazole (2-MIM) and thermally labile 5-aminotetrazole (5-AT) direct the formation of a hollow architecture that maximizes accessible Fe-N4 active sites and enhances mass transport. This design confers superior peroxidase-like activity, enabling catalytic oxidation of chromogenic substrates in the presence of H2O2 with high specificity toward INH. The resulting sensor achieves a detection limit of 0.24 μM and maintains high accuracy in human serum and urine, with minimal matrix interference. The entire assay is completed using a portable, low-cost device and a smartphone application for colorimetric analysis. Validated on human urine and serum, the platform demonstrates excellent reproducibility, stability, and field adaptability. This work presents a rational nanozyme design strategy through ligand-mediated structural control and establishes a scalable, equipment-free sensing framework for real-time therapeutic drug monitoring in POCT.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

IsoniazidSmartphonePoint-of-Care TestingAntitubercular AgentsPeroxidaseHumansColorimetryIronLigandsBiosensing TechniquesRapid Diagnostic Tests

Stichwörter der Autor:innen

ColorimetryIsoniazidNanozymesPeroxidase-like activityPoint-of-care testingPortable paper sensor

Substanzen

IsoniazidIronLigandsAntitubercular AgentsPeroxidase

Autor:innen und Institutionen

  • College of Chemistry, Liaoning University, Shenyang, 110036, China.
  • College of Chemistry, Liaoning University, Shenyang, 110036, China. Electronic address: xuxu@lnu.edu.cn.
  • College of Chemistry, Liaoning University, Shenyang, 110036, China. Electronic address: zhanglei63@126.com.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Zhou, X., Zhang, Y., Sun, T., Xu, X., & Zhang, L. (2026). Ligand-engineered hollow Fe-NC nanozymes with enhanced peroxidase activity for smartphone-based point-of-care testing of isoniazid. Analytica Chimica Acta, 1405, 345483. https://doi.org/10.1016/j.aca.2026.345483

Vancouver

Zhou X, Zhang Y, Sun T, Xu X, Zhang L. Ligand-engineered hollow Fe-NC nanozymes with enhanced peroxidase activity for smartphone-based point-of-care testing of isoniazid. Analytica Chimica Acta. 2026;1405:345483. doi:10.1016/j.aca.2026.345483

BibTeX
@article{Zhou2026,
  author = {Zhou, Xinyue and Zhang, Yu and Sun, Tongxin and Xu, Xu and Zhang, Lei},
  title = {Ligand-engineered hollow Fe-NC nanozymes with enhanced peroxidase activity for smartphone-based point-of-care testing of isoniazid},
  journal = {Analytica Chimica Acta},
  year = {2026},
  volume = {1405},
  pages = {345483},
  doi = {10.1016/j.aca.2026.345483}
}