EUVIMEDEUVIMED entdecken
Crossref

Optimized cleanup strategy for the determination of bisphenols in human serum with Na86(AlO2)86(SiO2)106 as sorbents: Molecular insights and critical factor evaluation

Jing Jin, Cuicui Guo, He Zhang, Tian Tian, Bairong Fu, Longxing Wang, Dongqin Tan, Jiajia Yang, Ningbo Geng, Jiping Chen

Analytica Chimica Acta · 2026-06 · 1402 · 345396

DOI: 10.1016/j.aca.2026.345396 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2026-06. Verfasst von Jing Jin und 9 weiteren Autor:innen. Beteiligte Einrichtung: Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, Liaoning, 116023, China. Electronic address: jinjing@dicp.ac.cn. Hauptthemen laut MEDLINE: Phenols, Zeolites, Solid Phase Extraction, Silicon Dioxide. Die Arbeit nennt 62 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND Bisphenols, as ubiquitous environmental contaminants, pose significant public health concerns owing to their endocrine-disrupting properties. While liquid chromatography-tandem mass spectrometry is the gold standard for their trace-level quantification in biological matrices, its accuracy is fundamentally limited by substantial matrix effects. The development of separation techniques and analytical method for human biomonitoring will significantly advance human health risk assessment. The complexity of biological matrices and low concentrations of targets are the main challenges for human biomonitoring. Developing accessible and economic SPE sorbents suitable for the cleanup of serum is pivotal for conducting large-scale epidemiological and toxicological studies of BPs. RESULTS We present a cleanup protocol based on a 13X-type Na86(AlO2)86(SiO2)106 zeolite, and it achieved consistent and acceptable matrix effect suppression (63.3%-121%), outperforming commercial alternatives like C18 (15.0%-107%), HLB (4.5%-87.7%), and PEP-2 (8.9%-142%). Correlation analysis suggested that analyte recovery was significantly associated with logKow (P < 0.01) and positively correlated with estimated molecular volume. Combining the binding energy analysis, our finding suggested the role of shape selectivity and strong interaction (e.g. hydrogen bond interaction, electrostatic interaction) within the zeolite pores. The developed method was validated with bovine serum, demonstrating acceptable sensitivity (0.075-0.39 ng mL-1), precision (2.2%-18.0%), and accuracy (71.4%-124%). Its reliability for human biomonitoring was further evaluated by the good agreement with a reference method via Bland-Altman analysis. SIGNIFICANCE The zeolite-based SPE protocol demonstrates good selectivity and robustness, establishing it as a superior sample preparation technique for the biomonitoring of BPs in serum. It is feasible for the accurate assessment of the human internal exposure to BPs. In addition, our work identifies critical factors influencing extraction efficiency and molecular interactions via multiple regression analysis and molecular simulation, thereby providing a possible mechanistic insight.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PhenolsZeolitesSolid Phase ExtractionSilicon DioxideBenzhydryl CompoundsHumansAdsorptionBisphenol A CompoundsTandem Mass Spectrometry

Stichwörter der Autor:innen

BisphenolCleanupMechanismMolecular sieveSolid-phase extraction

Substanzen

PhenolsZeolitesSilicon DioxideBenzhydryl CompoundsBisphenol A Compoundsbisphenol A

Autor:innen und Institutionen

  • Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, Liaoning, 116023, China. Electronic address: jinjing@dicp.ac.cn.
  • Henan Key Laboratory of Water Pollution Control and Rehabilitation Technology, Henan University of Urban Construction, Pingdingshan, 467036, China.
  • Dalian Women and Children's Medical Group, Dalian, 116011, China.
  • College of Materials Science and Engineering, Hebei University of Engineering, Hebei Province, China. Electronic address: tiantian19860102@126.com.
  • College of Environmental Science and Engineering, Dalian Maritime University, Liaoning Province, China.
  • Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, Liaoning, 116023, China.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Jin, J., Guo, C., Zhang, H., Tian, T., Fu, B., Wang, L., Tan, D., Yang, J., Geng, N., & Chen, J. (2026). Optimized cleanup strategy for the determination of bisphenols in human serum with Na86(AlO2)86(SiO2)106 as sorbents: Molecular insights and critical factor evaluation. Analytica Chimica Acta, 1402, 345396. https://doi.org/10.1016/j.aca.2026.345396

Vancouver

Jin J, Guo C, Zhang H, Tian T, Fu B, Wang L, et al. Optimized cleanup strategy for the determination of bisphenols in human serum with Na86(AlO2)86(SiO2)106 as sorbents: Molecular insights and critical factor evaluation. Analytica Chimica Acta. 2026;1402:345396. doi:10.1016/j.aca.2026.345396

BibTeX
@article{Jin2026,
  author = {Jin, Jing and Guo, Cuicui and Zhang, He and Tian, Tian and Fu, Bairong and Wang, Longxing and Tan, Dongqin and Yang, Jiajia and Geng, Ningbo and Chen, Jiping},
  title = {Optimized cleanup strategy for the determination of bisphenols in human serum with Na86(AlO2)86(SiO2)106 as sorbents: Molecular insights and critical factor evaluation},
  journal = {Analytica Chimica Acta},
  year = {2026},
  volume = {1402},
  pages = {345396},
  doi = {10.1016/j.aca.2026.345396}
}
Kostenlos starten →