EUVIMEDEUVIMED entdecken
Crossref

Portable smartphone-assisted fluorescence platform based on dual-excitation nitrogen-doped carbon dots for simultaneous detection of chlorogenic acid and tinidazole

Junyuan Shi, Zihang Yin, Dejin Lin, Dingfeng Wang, Siting Peng, Wendi Xiao, Houwen Hu, Jiong Cheng, Da Chen

Analytica Chimica Acta · 2026-06 · 1401 · 345333

DOI: 10.1016/j.aca.2026.345333 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2026-06. Verfasst von Junyuan Shi und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physics, School of Physical Science and Technology, Ningbo University, Ningbo, 315211, PR China. Hauptthemen laut MEDLINE: Carbon Quantum Dots, Tinidazole, Chlorogenic Acid, Smartphone. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 46 Literaturangaben. Gefördert von: K C Wong Magna Fund in Ningbo University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The pervasive issue of pharmaceutical overuse in agriculture and veterinary practice has led to the alarming accumulation of drug residues within the global food supply chain, posing a direct and escalating threat to consumer safety. Among these contaminants, compounds such as chlorogenic acid (CGA) and tinidazole (TNZ) are of particular concern due to their potential to provoke allergic responses and cause long-term adverse health effects. There is an urgent need for the development of rapid and reliable detection techniques capable of on-site monitoring to effectively mitigate these risks and ensure food safety. Herein, our work develops an innovative ratiometric sensing strategy that utilizes the dual-excitation properties of nitrogen-doped carbon dots (N-CDs) to simultaneously detect CGA and TNZ. Remarkably, as a fluorescent nanoprobe, N-CDs are capable of detecting CGA over a concentration range of 0.036-40 μM with a limit of detection (LOD) of 36 nM, which is attributed to static quenching (SQE) and the inner filter effect (IFE). Differently, the addition of TNZ results in fluorescence quenching of N-CDs via localization of inner filter effect (L-IFE), presenting the LOD of 68 nM within the 0.068-25 μM range. Furthermore, a portable smartphone-assisted platform which incorporates the N-CDs/PVA composite film successfully enables visual detection of CGA and TNZ with satisfactory recoveries in real samples. These results suggest that the developed portable smartphone-assisted fluorescence platform enables accurate dual-target detection of CGA and TNZ while offering outstanding stability and reproducibility suitable for on-site applications. Consequently, our methodology presents a versatile and practical strategy for real-time pharmaceutical residue screening, significantly advancing food safety monitoring capabilities.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Carbon Quantum DotsTinidazoleChlorogenic AcidSmartphoneQuantum DotsNitrogenSpectrometry, FluorescenceLimit of DetectionFluorescenceFluorescent Chemosensor CompoundsFluorescent DyesCarbon

Stichwörter der Autor:innen

Chlorogenic acidDual-excitation carbon dotsFluorescent filmRatiometric sensorTinidazoleVisual detection

Substanzen

NitrogenTinidazoleChlorogenic AcidFluorescent Chemosensor CompoundsFluorescent DyesCarbon

Autor:innen und Institutionen

  • Department of Physics, School of Physical Science and Technology, Ningbo University, Ningbo, 315211, PR China.
  • Key Laboratory for Liquid-Solid Structural Evolution and Processing of Materials, Ministry of Education, Shandong University, Jinan, 250061, PR China.
  • Department of Physics, School of Physical Science and Technology, Ningbo University, Ningbo, 315211, PR China. Electronic address: chengjiong@nbu.edu.cn.
  • Department of Physics, School of Physical Science and Technology, Ningbo University, Ningbo, 315211, PR China. Electronic address: chenda@nbu.edu.cn.

Förderung

  • K C Wong Magna Fund in Ningbo University

Zitieren

APA

Shi, J., Yin, Z., Lin, D., Wang, D., Peng, S., Xiao, W., Hu, H., Cheng, J., & Chen, D. (2026). Portable smartphone-assisted fluorescence platform based on dual-excitation nitrogen-doped carbon dots for simultaneous detection of chlorogenic acid and tinidazole. Analytica Chimica Acta, 1401, 345333. https://doi.org/10.1016/j.aca.2026.345333

Vancouver

Shi J, Yin Z, Lin D, Wang D, Peng S, Xiao W, et al. Portable smartphone-assisted fluorescence platform based on dual-excitation nitrogen-doped carbon dots for simultaneous detection of chlorogenic acid and tinidazole. Analytica Chimica Acta. 2026;1401:345333. doi:10.1016/j.aca.2026.345333

BibTeX
@article{Shi2026,
  author = {Shi, Junyuan and Yin, Zihang and Lin, Dejin and Wang, Dingfeng and Peng, Siting and Xiao, Wendi and Hu, Houwen and Cheng, Jiong and Chen, Da},
  title = {Portable smartphone-assisted fluorescence platform based on dual-excitation nitrogen-doped carbon dots for simultaneous detection of chlorogenic acid and tinidazole},
  journal = {Analytica Chimica Acta},
  year = {2026},
  volume = {1401},
  pages = {345333},
  doi = {10.1016/j.aca.2026.345333}
}
Kostenlos starten →