Ionic-liquid-based aqueous biphasic systems meet microfluidics: from antibodies to aptamers in prostate-specific antigen detection
Analytica Chimica Acta · 2026
DOI: 10.1016/j.aca.2025.345001 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2026. Verfasst von Maria S M Mendes und 4 weiteren Autor:innen. Beteiligte Einrichtung: CICECO - Aveiro Institute of Materials, Department of Chemistry, University of Aveiro, Aveiro, Portugal; Instituto de Engenharia de Sistemas e Comput…. Hauptthemen laut MEDLINE: Prostate-Specific Antigen, Aptamers, Nucleotide, Microfluidic Analytical Techniques, Antibodies. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fundação para a Ciência e a Tecnologia.
Abstract (Originalsprache)
BACKGROUND: Prostate-specific antigen (PSA) is the most widely used biomarker for prostate cancer screening; still, its reliable quantification in human serum remains challenging due to matrix complexity and high-abundance proteins that interfere with target recognition and signal generation. These limitations reduce the performance of biosensing microfluidic platforms. Ionic-liquid-based aqueous biphasic systems (IL-ABS) have been proposed as effective serum pretreatment tools, enabling selective depletion of high-abundance proteins, analyte preconcentration, and seamless integration with microfluidic devices. However, the synergistic combination of IL-ABS with microfluidic immunoassays has so far been restricted to antibody-based formats, which are limited in stability, cost, and target accessibility. RESULTS: Here, the analytical scope of the combined IL-ABS pretreatment and microfluidic detection platform is expanded beyond conventional antibody-based formats by introducing aptamers as recognition elements. The resulting aptamer-based sandwich immunoassay was benchmarked against the conventional antibody-antibody format, demonstrating superior sensitivity and a limit of detection of 7.49 ng mL-1, within the clinically relevant range for PSA screening. SIGNIFICANCE: This work pioneers the combined use of IL-ABS pretreatment and aptamer-based microfluidic detection for PSA. Aptamers, as synthetic ligands, offer high specificity, enhanced stability, and flexible design, providing a cost-effective alternative to antibodies. Incorporating aptamer recognition enhances analytical performance relative to conventional antibody-based assays, highlighting the platform's potential for broader clinical and point-of-care applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- CICECO - Aveiro Institute of Materials, Department of Chemistry, University of Aveiro, Aveiro, Portugal; Instituto de Engenharia de Sistemas e Computadores - Microssistemas e Nanotecnologias (INESC MN), Lisbon, Portugal.
- Instituto de Engenharia de Sistemas e Computadores - Microssistemas e Nanotecnologias (INESC MN), Lisbon, Portugal.
- CICECO - Aveiro Institute of Materials, Department of Chemistry, University of Aveiro, Aveiro, Portugal.
- CICECO - Aveiro Institute of Materials, Department of Chemistry, University of Aveiro, Aveiro, Portugal. Electronic address: francisca.silva@ua.pt.
- Instituto de Engenharia de Sistemas e Computadores - Microssistemas e Nanotecnologias (INESC MN), Lisbon, Portugal; Department of Bioengineering, Instituto Superior Técnico, Universidade de Lisboa, Lisbon, Portugal. Ele…
Förderung
- Fundação para a Ciência e a Tecnologia
Zitieren
APA
Mendes, M. S. M., Chu, V., Freire, M. G., E Silva, F. A., & Conde, J. P. (2026). Ionic-liquid-based aqueous biphasic systems meet microfluidics: from antibodies to aptamers in prostate-specific antigen detection. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2025.345001
Vancouver
Mendes MSM, Chu V, Freire MG, E Silva FA, Conde JP. Ionic-liquid-based aqueous biphasic systems meet microfluidics: from antibodies to aptamers in prostate-specific antigen detection. Analytica Chimica Acta. 2026. doi:10.1016/j.aca.2025.345001
BibTeX
@article{Mendes2026,
author = {Mendes, Maria S M and Chu, Virginia and Freire, Mara G and E Silva, Francisca A and Conde, João P},
title = {Ionic-liquid-based aqueous biphasic systems meet microfluidics: from antibodies to aptamers in prostate-specific antigen detection},
journal = {Analytica Chimica Acta},
year = {2026},
doi = {10.1016/j.aca.2025.345001}
}
EUVIMED