EUVIMEDEUVIMED entdecken
Crossref

A persistent luminescent lateral flow immunoassay for rapid and accurate detection of estradiol in real samples

Chao Huang, Bingni Jia, Runqi Jiang, Qi Li, Xiaofeng Liu, Caicheng Long, Peng Zhang, Bo Feng, Taiping Qing

Analytica Chimica Acta · 2026

DOI: 10.1016/j.aca.2025.344813 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2026. Verfasst von Chao Huang und 8 weiteren Autor:innen. Beteiligte Einrichtung: College of Environment and Resources, Hunan Provincial University Key Laboratory for Environmental and Ecological Health, Xiangtan University, Xiangt…. Hauptthemen laut MEDLINE: Estradiol, Luminescent Measurements, Water Pollutants, Chemical. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: Ministry of Ecology and Environment, The People’s Republic of China, National Aerospace Science Foundation of China, Science and Technology Innovative Research Team in Higher Educational Institutions of Hunan Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: The demand for highly sensitive and reliable environmental monitoring methods has led to extensive research on new rapid detection technologies. Fluorescent immunochromatographic test strips are widely used for the detection of endocrine disruptors due to their advantages of rapid response, high sensitivity, and good selectivity. However, most current lateral flow immunoassay (LFIA) use excitation-dependent organic fluorescent molecules or quantum dots as signal label, which are susceptible to interference from background fluorescence in complex samples, thereby reducing their accuracy and sensitivity in real sample detection. RESULTS: In this work, a novel immunochromatographic test strip was constructed for the anti-interference detection of endocrine disruptors in complex samples using persistent luminescent nanomaterials as signal units and antibodies for specific recognition of target molecule. The synthesized Zn2GeO4:Mn (ZGO:Mn) persistent luminescent nanomaterials possessed bright green luminescence after excitation turn off, allowing eliminate sample autofluorescence interference. As the proof-of-concept of this novel LFIA, estradiol (E2) was chosen as a model system to be investigated. After optimization, the persistent luminescent LFIA exhibited a good linear range from 0 to 15 μg/L with the limit of detection of 507 ng/L for E2, which are below the concentration range of E2 in most municipal wastewater systems. In addition, the persistent luminescent LFIA had strong specificity and high accuracy for E2 detection in water samples and milk samples. SIGNIFICANCE: This study introduces a persistent luminescent lateral flow immunoassay for E2 detection with minimized background interference. Significantly, this persistent luminescent LFIA has better detection performance than traditional fluorescent LFIA, showing tremendous potential for determination and control of E2 in real samples.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

EstradiolLuminescent MeasurementsWater Pollutants, ChemicalImmunoassayMilkAnimalsLimit of DetectionLuminescence

Stichwörter der Autor:innen

Anti-interferenceEstradiolLateral flow immunoassayOn-side detectionPersistent luminescence

Substanzen

EstradiolWater Pollutants, Chemical

Autor:innen und Institutionen

  • College of Environment and Resources, Hunan Provincial University Key Laboratory for Environmental and Ecological Health, Xiangtan University, Xiangtan, 411105, Hunan, China.
  • Hunan Institute of Advanced Sensing and Information Technology, Xiangtan University, Xiangtan, 411105, Hunan, China.
  • College of Environment and Resources, Hunan Provincial University Key Laboratory for Environmental and Ecological Health, Xiangtan University, Xiangtan, 411105, Hunan, China; Chenjiang Laboratory, Chenzhou, 423000, Chin…
  • College of Environment and Resources, Hunan Provincial University Key Laboratory for Environmental and Ecological Health, Xiangtan University, Xiangtan, 411105, Hunan, China; National Engineering Research Center of Adva…

Förderung

  • Ministry of Ecology and Environment, The People’s Republic of China
  • National Aerospace Science Foundation of China
  • Science and Technology Innovative Research Team in Higher Educational Institutions of Hunan Province
  • National Natural Science Foundation of China

Zitieren

APA

Huang, C., Jia, B., Jiang, R., Li, Q., Liu, X., Long, C., Zhang, P., Feng, B., & Qing, T. (2026). A persistent luminescent lateral flow immunoassay for rapid and accurate detection of estradiol in real samples. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2025.344813

Vancouver

Huang C, Jia B, Jiang R, Li Q, Liu X, Long C, et al. A persistent luminescent lateral flow immunoassay for rapid and accurate detection of estradiol in real samples. Analytica Chimica Acta. 2026. doi:10.1016/j.aca.2025.344813

BibTeX
@article{Huang2026,
  author = {Huang, Chao and Jia, Bingni and Jiang, Runqi and Li, Qi and Liu, Xiaofeng and Long, Caicheng and Zhang, Peng and Feng, Bo and Qing, Taiping},
  title = {A persistent luminescent lateral flow immunoassay for rapid and accurate detection of estradiol in real samples},
  journal = {Analytica Chimica Acta},
  year = {2026},
  doi = {10.1016/j.aca.2025.344813}
}
Kostenlos starten →