Signal-boosted Eu2O3-based time-resolved fluorescence immunosensor for the ultrasensitive detection of cardiac troponin T
Analytica Chimica Acta · 2026-01 · 1381 · 344793
DOI: 10.1016/j.aca.2025.344793 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2026-01. Verfasst von Feifan Cheng und 6 weiteren Autor:innen. Beteiligte Einrichtung: College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, 310016, China. Hauptthemen laut MEDLINE: Troponin T, Europium. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 42 Literaturangaben. Gefördert von: Zhejiang Sci-Tech University, Natural Science Foundation of Zhejiang Province, Department of Education of Zhejiang Province.
Abstract (Originalsprache)
BACKGROUND: Time-resolved fluorescence immunoassays (TRFIA) have been extensively applied across various fields owing to their low background noise characteristics, particularly in disease diagnosis and prevention. Survival and prognosis of patients with acute myocardial infarction (AMI) are highly dependent on the rapid and accurate detection of myocardial damage. Troponin T (cTnT) is a primary diagnostic biomarker of AMI and is widely used in clinical practice. However, the current bioassays for cTnT detection are complex and time-consuming. Therefore, there is an urgent need for a sensitivity, and rapid diagnostic approach for acute myocardial infarction. RESULTS: Herein, we report a novel, sensitive, and specific cTnT detection approach using a unique nanoprobe dissolution-enhanced fluorescence amplification strategy. Eu2O3 nanocrystals, easily dissolvable in an acidic enhancer solution and transformed into many highly luminescent Eu3+ micelles, were utilized as nanoprobes. The released Eu3+ further activates the time-resolved fluorescence system, which prevents autofluorescence interference and blood scattering, allowing for the accurate determination of cTnT levels in clinical serum samples. The demonstrated sensitivity of serum cTnT was high with a sensitivity of 3.86 ng·L-1. In addition, we developed a Eu2O3-based lateral flow immunochromatographic test strip for facile cTnT detection, with the sensitivity of 14.14 ng·L-1 and 6.31 ng·L-1 using smartphone-integrated app and commercial analyzer respectively. SIGNIFICANCE: This Eu2O3-nanocrystal-based dissolution-enhanced luminescent bioassay has tremendous potential for ultrasensitive biomarker detection, enabling ultra-trace detection through lanthanide-specific dissolution. Moreover, the surface-functionalized nanocrystals could selectively recognize a variety of analytes, and have excellent photostability with minimal matrix interference, expanding the direction of lanthanide nanoprobes in multifunctional diagnostic and therapeutic areas.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, 310016, China.
- Department of Emergency, Zhejiang Provincial People's Hospital, People's Hospital of Hangzhou Medical College, Hangzhou, 310014, China.
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, 310016, China. Electronic address: zhaoxueqin@zstu.edu.cn.
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, 310016, China. Electronic address: huangbiao@zstu.edu.cn.
Förderung
- Zhejiang Sci-Tech University
- Natural Science Foundation of Zhejiang Province
- Department of Education of Zhejiang Province
Zitieren
APA
Cheng, F., Huang, S., Zhai, C., Li, Q., Lv, W., Zhao, X., & Huang, B. (2026). Signal-boosted Eu2O3-based time-resolved fluorescence immunosensor for the ultrasensitive detection of cardiac troponin T. Analytica Chimica Acta, 1381, 344793. https://doi.org/10.1016/j.aca.2025.344793
Vancouver
Cheng F, Huang S, Zhai C, Li Q, Lv W, Zhao X, et al. Signal-boosted Eu2O3-based time-resolved fluorescence immunosensor for the ultrasensitive detection of cardiac troponin T. Analytica Chimica Acta. 2026;1381:344793. doi:10.1016/j.aca.2025.344793
BibTeX
@article{Cheng2026,
author = {Cheng, Feifan and Huang, Shihan and Zhai, Chunlian and Li, Qian and Lv, Wei and Zhao, Xueqin and Huang, Biao},
title = {Signal-boosted Eu2O3-based time-resolved fluorescence immunosensor for the ultrasensitive detection of cardiac troponin T},
journal = {Analytica Chimica Acta},
year = {2026},
volume = {1381},
pages = {344793},
doi = {10.1016/j.aca.2025.344793}
}
EUVIMED