DNAzyme-CRISPR driven dual-mode biosensor with nanozyme signal amplification for on-site Pb2+ detection
Analytica Chimica Acta · 2025-12 · 1379 · 344711
DOI: 10.1016/j.aca.2025.344711 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2025-12. Verfasst von Xin Meng und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Food Science and Pharmaceutical Engineering, Nanjing Normal University, Nanjing, 210023, PR China. Hauptthemen laut MEDLINE: Lead, DNA, Catalytic, Biosensing Techniques, CRISPR-Cas Systems. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 65 Literaturangaben. Gefördert von: Key University Science Research Project of Jiangsu Province.
Abstract (Originalsprache)
BACKGROUND: Lead ion (Pb2+) is a toxic heavy metal that poses severe threats to food safety. Traditional methods like inductively coupled plasma mass spectrometry (ICP-MS) and atomic absorption spectrometry (AAS) rely on bulky instrumentation, which are limited by high costs, complex sample preparation requirements, and inability to meet the demands for rapid on-site testing. Nanozyme-based biosensors have emerged as promising alternatives, yet single-mode sensors often suffer from matrix interference in complex food samples. Therefore, developing a rapid and reliable on-site method is critical for Pb2+ detection. RESULTS: To address this challenge, a CRISPR/Cas12a-driven dual-mode biosensor integrating Pt/CeO2 nanozyme-mediated peroxidase activity with GR-5 DNAzyme recognition was developed. The biosensor's design capitalizes on GR-5 DNAzyme for Pb2+-specific recognition, triggering CRISPR/Cas12a-mediated cleavage of electrochemical/colorimetric signal probe SH-ssDNA-Pt/CeO2 to generate dual signals. This innovative platform synergizes electrochemical precision and colorimetric simplicity for Pb2+ detection in complex food matrices. The biosensor achieved an ultra-sensitive electrochemical response (linear range: 0.002-200 nM; limit of detection: 0.14 pM) alongside a robust colorimetric readout (linear range: 0.5-2000 nM; limit of detection: 0.47 nM), representing significant sensitivity improvements over conventional single-mode sensors. Crucially, the intrinsic cross-verification mechanism between orthogonal signal modalities minimized false positives while ensuring >90.5 % recovery in spiked corn, edible oil, beef and red wine samples with RSD
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Food Science and Pharmaceutical Engineering, Nanjing Normal University, Nanjing, 210023, PR China.
- School of Food Science and Pharmaceutical Engineering, Nanjing Normal University, Nanjing, 210023, PR China; Wuhu Yiju Central Kitchen Catering Management Co., Ltd., Anhui, 241006, PR China.
- National Engineering Research Center of Solid-state Brewing, Luzhou, 646000, PR China.
- Institute of Cereal & Oil Science and Technology, Academy of National Food and Strategic Reserves Administration, Pilot Base of ASAG, No.26 Dongbei Road, Beiqijia Town, Changping District, Beijing, 102209, PR China.
- School of Food Science and Pharmaceutical Engineering, Nanjing Normal University, Nanjing, 210023, PR China; Food Laboratory of Zhongyuan, Luohe, 462300, Henan, PR China. Electronic address: wuln@njnu.edu.cn.
Förderung
- Key University Science Research Project of Jiangsu Province
Zitieren
APA
Meng, X., Yue, Y., Huang, M., Duan, Z., Liu, K., & Wu, L. (2025). DNAzyme-CRISPR driven dual-mode biosensor with nanozyme signal amplification for on-site Pb2+ detection. Analytica Chimica Acta, 1379, 344711. https://doi.org/10.1016/j.aca.2025.344711
Vancouver
Meng X, Yue Y, Huang M, Duan Z, Liu K, Wu L. DNAzyme-CRISPR driven dual-mode biosensor with nanozyme signal amplification for on-site Pb2+ detection. Analytica Chimica Acta. 2025;1379:344711. doi:10.1016/j.aca.2025.344711
BibTeX
@article{Meng2025,
author = {Meng, Xin and Yue, Yuanyuan and Huang, Mengyang and Duan, Zhangqun and Liu, Kang and Wu, Lina},
title = {DNAzyme-CRISPR driven dual-mode biosensor with nanozyme signal amplification for on-site Pb2+ detection},
journal = {Analytica Chimica Acta},
year = {2025},
volume = {1379},
pages = {344711},
doi = {10.1016/j.aca.2025.344711}
}
EUVIMED