Fachartikel in der Zeitschrift Analytica Chimica Acta, 2025-12. Verfasst von Dujuan Li und 8 weiteren Autor:innen. Beteiligte Einrichtung: Ministry of Education Engineering Research Center of Smart Microsensors and Microsystems, School of Electronics and Information, Hangzhou Dianzi Univ…. Hauptthemen laut MEDLINE: Sweat, Copper, Glucose, Biosensing Techniques. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 59 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Fundamental Research Funds for the Provincial Universities of Zhejiang Province, Zhejiang Province Natural Science Foundation.
Abstract (Originalsprache)
BACKGROUND: Traditional blood glucose monitoring requires piercing the skin to obtain blood samples, which brings inconvenience and discomfort to diabetic patients. Sweat glucose content has been proven to be related to blood glucose concentration, so sweat glucose detection shows significant advantages in non-invasive blood glucose monitoring. The performance of enzyme-based glucose sensors is easily affected by external environments such as temperature and pH. Therefore, there is an urgent need to develop non-enzymatic glucose sensors with good stability, low cost and high performance for sweat glucose detection. RESULTS: In this study, a non-enzymatic glucose sensor had been successfully fabricated by integrating copper oxide (CuO) nanoparticles with tungsten disulfide (WS2) nanosheets obtained via a liquid-phase exfoliation method. The sensor was characterized using scanning electron microscopy (SEM) and electrochemical measurements, showing that WS2/CuO nanocomposites formed a honeycombed-like surface improving the catalytic ability of glucose. The fabricated non-enzymatic amperometric glucose sensor is capable of detecting a wide range of target concentrations, from 0.1 mM to 20 mM. The experiment found that the sensor response signal has a linear relationship with the target concentration in the range of 0.1 mM-2 mM and 2 mM-20 mM, respectively, and the corresponding detection sensitivities are 311.23 μA mM-1 cm-2 and 238.3 μA mM-1 cm-2 under optimized experimental conditions. The sensor has a detection limit as low as 0.65 μM. The sensor also has good selectivity, repeatability, reproducibility and stability. Finally, the fabricated sensor was applied to the detection of glucose in artificial sweat and human sweat. SIGNIFICANCE: The experimental results compared with the spectrophotometric method illustrate the excellent accuracy of the non-enzymatic glucose sensor proposed in this study in detecting real sweat sample analysis, highlighting its great potential for future practical applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Ministry of Education Engineering Research Center of Smart Microsensors and Microsystems, School of Electronics and Information, Hangzhou Dianzi University, Hangzhou, 310018, China. Electronic address: dujuanli@hdu.edu.…
- Ministry of Education Engineering Research Center of Smart Microsensors and Microsystems, School of Electronics and Information, Hangzhou Dianzi University, Hangzhou, 310018, China.
- Ministry of Education Engineering Research Center of Smart Microsensors and Microsystems, School of Electronics and Information, Hangzhou Dianzi University, Hangzhou, 310018, China. Electronic address: wxy317@hdu.edu.cn.
- Department of Infectious Diseases, The Third Affiliated Hospital of Wenzhou Medical University (Ruian People's Hospital), Ruian, 325200, China. Electronic address: rahoshongliang@163.com.
- Guangdong Technology Research Center for Marine Algal Bioengineering, College of Life Sciences and Oceanography, Shenzhen University, Shenzhen, 518060, China.
Förderung
- National Natural Science Foundation of China
- Fundamental Research Funds for the Provincial Universities of Zhejiang Province
- Zhejiang Province Natural Science Foundation
Zitieren
APA
Li, D., Yang, M., Li, W., Wang, A., Wang, X., Hong, L., Dong, L., Xu, H., & Wang, G. (2025). WS2/CuO-based non-enzymatic sensor for the detection of glucose in sweat. Analytica Chimica Acta, 1378, 344696. https://doi.org/10.1016/j.aca.2025.344696
Vancouver
Li D, Yang M, Li W, Wang A, Wang X, Hong L, et al. WS2/CuO-based non-enzymatic sensor for the detection of glucose in sweat. Analytica Chimica Acta. 2025;1378:344696. doi:10.1016/j.aca.2025.344696
BibTeX
@article{Li2025,
author = {Li, Dujuan and Yang, Mingzhu and Li, Wenhui and Wang, Ao and Wang, Xinyi and Hong, Liang and Dong, Linxi and Xu, Hong and Wang, Gaofeng},
title = {WS2/CuO-based non-enzymatic sensor for the detection of glucose in sweat},
journal = {Analytica Chimica Acta},
year = {2025},
volume = {1378},
pages = {344696},
doi = {10.1016/j.aca.2025.344696}
}
EUVIMED