Fachartikel in der Zeitschrift Analytica Chimica Acta, 2025-12. Verfasst von Zhongheng Wei und 9 weiteren Autor:innen. Beteiligte Einrichtung: Guangxi Clinical Medical Research Center for Hepatobiliary Diseases, Affiliated Hospital of Youjiang Medical University for Nationalities, Baise, Gua…. Hauptthemen laut MEDLINE: Biosensing Techniques, G-Quadruplexes, Flap Endonucleases, Electrochemical Techniques. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 81 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Nanjing University State Key Laboratory of Analytical Chemistry for Life Science, Guangxi Natural Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Flap endonuclease 1 (FEN1) is crucial for DNA replication, repair, and telomere maintenance. Its dysregulation is linked to various cancers and diseases. Accurate detection of FEN1 is essential for early diagnosis and therapeutic monitoring. Thus, a novel electrochemiluminescent (ECL) biosensor has been developed for the structure-specific and detection of FEN1. The strategy integrates dumbbell DNA probe-mediated transcription and CRISPR/Cas13a-induced trans-cleavage of RNA G-quadruplexes. In the presence of FEN1, the 5'-flap structure of the probe was selectively cleaved and subsequently ligated by T4 DNA ligase to form a closed circular template. This enabled T7 RNA polymerase to transcribe crRNA-encoded RNA strands, which activated Cas13a to cleave surface-tethered G-quadruplexes/hemin complexes on a Ru(II)/Ti3C2/AuNPs-modified electrode, thereby restoring the quenched ECL signal. The biosensor exhibited an ultralow detection limit of 4.82 × 10-9 U μL-1 and a wide dynamic range (1 × 10-8 to 1 × 10-5 U μL-1), along with excellent specificity and stability. Successful application in human serum validated its reliability for complex biological samples. This work presents a powerful platform for sensitive FEN1 monitoring, holding potential for clinical diagnostics and enzymatic analysis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesG-QuadruplexesFlap EndonucleasesElectrochemical TechniquesCRISPR-Cas SystemsLuminescent MeasurementsDNA ProbesCRISPR-Associated ProteinsHumansLimit of DetectionTranscription, Genetic

Stichwörter der Autor:innen

CRISPR/Cas13aDumbbell DNA probeElectrochemiluminescenceFEN1 detectionG-quadruplexes RNAT7 RNA polymerase

Substanzen

Flap EndonucleasesFEN1 protein, humanDNA ProbesCRISPR-Associated Proteins

Autor:innen und Institutionen

  • Guangxi Clinical Medical Research Center for Hepatobiliary Diseases, Affiliated Hospital of Youjiang Medical University for Nationalities, Baise, Guangxi, 5333000, China.
  • Key Laboratory of Guangxi's Colleges for the Study of Characteristic Ethnic Medicine in Youjiang River Basin, Youjiang Medical University for Nationalities, Baise, Guangxi, 533000, China.
  • Key Laboratory of Guangxi's Colleges for the Study of Characteristic Ethnic Medicine in Youjiang River Basin, Youjiang Medical University for Nationalities, Baise, Guangxi, 533000, China. Electronic address: huanglongji…
  • School of Chemistry and Materials Science, Nanjing University of Information Science and Technology, Nanjing, 210044, China. Electronic address: kaizhang@nuist.edu.cn.
  • Key Laboratory of Guangxi's Colleges for the Study of Characteristic Ethnic Medicine in Youjiang River Basin, Youjiang Medical University for Nationalities, Baise, Guangxi, 533000, China. Electronic address: lxj2009919@…

Förderung

  • National Natural Science Foundation of China
  • Nanjing University State Key Laboratory of Analytical Chemistry for Life Science
  • Guangxi Natural Science Foundation

Zitieren

APA

Wei, Z., Luo, H., Huang, D., Wei, P., Zhang, J., Wei, J., Tang, Q., Huang, L., Zhang, K., & Liao, X. (2025). Structure-specific electrochemiluminescent biosensor for FEN1 detection via dumbbell probe-mediated transcription and CRISPR/Cas13a-induced G-quadruplexes cleavage. Analytica Chimica Acta, 1377, 344662. https://doi.org/10.1016/j.aca.2025.344662

Vancouver

Wei Z, Luo H, Huang D, Wei P, Zhang J, Wei J, et al. Structure-specific electrochemiluminescent biosensor for FEN1 detection via dumbbell probe-mediated transcription and CRISPR/Cas13a-induced G-quadruplexes cleavage. Analytica Chimica Acta. 2025;1377:344662. doi:10.1016/j.aca.2025.344662

BibTeX
@article{Wei2025,
  author = {Wei, Zhongheng and Luo, Huini and Huang, Danlu and Wei, Peixin and Zhang, Jiayi and Wei, Jihua and Tang, Qianli and Huang, Longjian and Zhang, Kai and Liao, Xianjiu},
  title = {Structure-specific electrochemiluminescent biosensor for FEN1 detection via dumbbell probe-mediated transcription and CRISPR/Cas13a-induced G-quadruplexes cleavage},
  journal = {Analytica Chimica Acta},
  year = {2025},
  volume = {1377},
  pages = {344662},
  doi = {10.1016/j.aca.2025.344662}
}
Kostenlos starten →