High-precision in-situ determination of silver isotopes in argentiferous minerals by fsLA-MC-ICP-MS
Analytica Chimica Acta · 2025-12 · 1377 · 344657
DOI: 10.1016/j.aca.2025.344657 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2025-12. Verfasst von Deyi Peng und 5 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Continental Evolution and Early Life, Department of Geology, Northwest University, Xi'an, 710069, China. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 59 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Mineral Resources, Ministry of Science and Technology of the People's Republic of China.
Abstract (Originalsprache)
BACKGROUND: Silver (Ag) isotopes have emerged as effective tracers for investigating processes in Earth sciences, planetary evolution and archaeology. Conventional bulk Ag isotope analysis is typically performed using solution nebulizer (SN-) multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS), which lacks spatial resolution and may mask heterogeneities within samples. In contrast, in-situ Ag isotope analysis enables precise detection of inter- and intragranular isotope variations, thanks to its high spatial resolution and analytical throughput. However, in-situ methods remain unreported. The scarcity of matrix-matched reference materials and the limited understanding of matrix effects among diverse samples are major constraints on the advancement of in-situ Ag isotope analysis. RESULTS: This paper presents a robust in-situ Ag isotope analysis method for argentiferous minerals (electrum, tetrahedrite, proustite, native silver, and argentite), which is implemented using femtosecond laser ablation (LA) MC-ICP-MS. Significant matrix effects were observed among these argentiferous minerals during non-matrix-matched calibration under dry plasma conditions; however, these effects were effectively suppressed by introducing water vapor during in-situ analysis. Nonetheless, matrix effects persist when argentite was used to correct electrum, even under wet plasma conditions. Therefore, to ensure reliable in-situ results, the application of matrix-matched reference materials is indispensable. Four potential in-house reference materials were developed for in-situ Ag isotope analysis. Measured δ109AgNIST 978a values (2SD, n = 3-4) by solution nebulizer method for native silver, argentite, tetrahedrite, and proustite are 0.00 ± 0.01 ‰, 0.13 ± 0.03 ‰, 0.23 ± 0.01 ‰, and -0.17 ± 0.01 ‰, respectively, recommended as reference values. SIGNIFICANCE: For the first time, an in-situ Ag isotope ratios analysis method for argentiferous minerals (electrum, tetrahedrite, proustite, native silver, and argentite) was developed using fsLA-MC-ICP-MS. A systematic evaluation of matrix effects in the five argentiferous minerals was conducted under both dry and wet plasma conditions. Additionally, four potential natural in-house reference materials for in-situ Ag isotope analysis using LA-MC-ICP-MS are proposed. This work is expected to broaden the applications of in-situ Ag isotopes.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- State Key Laboratory of Continental Evolution and Early Life, Department of Geology, Northwest University, Xi'an, 710069, China.
- State Key Laboratory of Continental Evolution and Early Life, Department of Geology, Northwest University, Xi'an, 710069, China. Electronic address: geobza@126.com.
- State Key Laboratory of Continental Evolution and Early Life, Department of Geology, Northwest University, Xi'an, 710069, China. Electronic address: yhlsklcd@126.com.
Förderung
- National Natural Science Foundation of China
- Mineral Resources
- Ministry of Science and Technology of the People's Republic of China
- National Science and Technology Major Project
Zitieren
APA
Peng, D., Bao, Z., Liu, P., Tian, Y., Chen, K., & Yuan, H. (2025). High-precision in-situ determination of silver isotopes in argentiferous minerals by fsLA-MC-ICP-MS. Analytica Chimica Acta, 1377, 344657. https://doi.org/10.1016/j.aca.2025.344657
Vancouver
Peng D, Bao Z, Liu P, Tian Y, Chen K, Yuan H. High-precision in-situ determination of silver isotopes in argentiferous minerals by fsLA-MC-ICP-MS. Analytica Chimica Acta. 2025;1377:344657. doi:10.1016/j.aca.2025.344657
BibTeX
@article{Peng2025,
author = {Peng, Deyi and Bao, Zhian and Liu, Peng and Tian, Yongfei and Chen, Kaiyun and Yuan, Honglin},
title = {High-precision in-situ determination of silver isotopes in argentiferous minerals by fsLA-MC-ICP-MS},
journal = {Analytica Chimica Acta},
year = {2025},
volume = {1377},
pages = {344657},
doi = {10.1016/j.aca.2025.344657}
}
EUVIMED