Highly sensitive ratiometric pH nanoprobe based on CuNCs–Rh6G for monitoring intracellular pH and meat freshness
Analytica Chimica Acta · 2025
DOI: 10.1016/j.aca.2025.344650 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2025. Verfasst von Xiaoyuan Xu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Sichuan University, Chengdu, 610064, Sichuan, China. Hauptthemen laut MEDLINE: Rhodamines, Copper, Fluorescent Dyes, Meat. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 46 Literaturangaben. Gefördert von: Henan Normal University, National Natural Science Foundation of China.
Abstract (Originalsprache)
BACKGROUND: Copper nanoclusters (CuNCs) have received a lot of attention in the construction of fluorescence sensors. However, the considerably lower oxidation potential of Cu makes CuNCs inherently vulnerable to oxidation. This instability manifests as short shelf lives and low fluorescence quantum yield, posing a major limitation for their deployment in sensing technologies. To overcome this problem, it is very important to choose the suitable reducing agent and protective agent, which can control the growth of NCs and further influence their properties. RESULTS: In this work, fluorescent CuNCs with good pH sensitivity were one-pot synthesized using vitamin B1 (VB1) as both stabilizer and reducing agent at room temperature. To leverage the advantages of ratiometric detection, Rhodamine 6G (Rh6G) was incorporated, creating the CuNCs-Rh6G nanocomplex. This nanoprobe displayed dual emission peaks at 440 nm (pH-sensitive) and 550 nm (pH-inert reference) under single-wavelength excitation. Crucially, the intensity ratio (I440nm/I550nm) provided a linear response to pH from 4.61 to 7.83. Concurrently, the solution fluorescence visually shifted from blue to bright yellow as pH decreased from 9.0 to 3.0, enabling sensitive visual detection. The nanoprobe demonstrated excellent reversibility, photostability, high sensitivity (ΔpH = 0.05), biocompatibility, and low cytotoxicity. Based on these properties, CuNCs-Rh6G successfully imaged intracellular pH changes using dual-channel microscopy. Furthermore, it enabled specific, visualized pH monitoring in meat samples. To facilitate practical application, test strips functionalized with CuNCs-Rh6G were developed for convenient meat freshness assessment. SIGNIFICANCE: This work presents a novel approach to developing highly stable copper nanoclusters. Also, these findings collectively establish CuNCs-Rh6G as a sensitive visual biosensor platform for tracking pH variations, supporting applications in clinical diagnostics and food preservation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, Sichuan University, Chengdu, 610064, Sichuan, China.
- School of Chemistry and Chemical Engineering, Henan Normal University, Xinxiang, 453000, Henan, China.
- Department of Chemistry, Sichuan University, Chengdu, 610064, Sichuan, China. Electronic address: dujuanchem@scu.edu.cn.
- Department of Chemistry, Sichuan University, Chengdu, 610064, Sichuan, China. Electronic address: zhengbaozhan@scu.edu.cn.
- Department of Chemistry, Sichuan University, Chengdu, 610064, Sichuan, China. Electronic address: guoy@scu.edu.cn.
Förderung
- Henan Normal University
- National Natural Science Foundation of China
Zitieren
APA
Xu, X., He, R., Xie, Z., Shu, Y., Wang, H., Du, J., Zheng, B., & Guo, Y. (2025). Highly sensitive ratiometric pH nanoprobe based on CuNCs–Rh6G for monitoring intracellular pH and meat freshness. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2025.344650
Vancouver
Xu X, He R, Xie Z, Shu Y, Wang H, Du J, et al. Highly sensitive ratiometric pH nanoprobe based on CuNCs–Rh6G for monitoring intracellular pH and meat freshness. Analytica Chimica Acta. 2025. doi:10.1016/j.aca.2025.344650
BibTeX
@article{Xu2025,
author = {Xu, Xiaoyuan and He, Rongpei and Xie, Zhenyu and Shu, Yaxi and Wang, Huiyong and Du, Juan and Zheng, Baozhan and Guo, Yong},
title = {Highly sensitive ratiometric pH nanoprobe based on CuNCs–Rh6G for monitoring intracellular pH and meat freshness},
journal = {Analytica Chimica Acta},
year = {2025},
doi = {10.1016/j.aca.2025.344650}
}
EUVIMED