Identification of micro-/nanoplastics in human placental blood using comprehensive multidimensional pyrolysis - gas chromatography x ion mobility mass spectrometry

Justine R Bissonnette, Nikita E Harvey, Mikela L Rowsell, Sophie Kiefte, Kas J Houthuijs, Frederic M Béen, Marja H Lamoree, Lindsay S Cahill, Karl J Jobst

Analytica Chimica Acta · 2025-11 · 1376 · 344606

DOI: 10.1016/j.aca.2025.344606 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2025-11. Verfasst von Justine R Bissonnette und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Memorial University of Newfoundland, 45 Arctic Ave., St. John's, Newfoundland and Labrador, Canada. Hauptthemen laut MEDLINE: Placenta, Microplastics. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Health Canada, Natural Sciences and Engineering Research Council of Canada, Canada Foundation for Innovation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Micro-/nanoplastics (MNPs) are ubiquitous environmental contaminants and there has been a growing concern about their potential adverse effects on human health. The present study reports on the development of a novel pyrolysis-gas chromatography x ion mobility mass spectrometry method to identify MNPs in placental blood, while reducing false positive detections from matrix interferences. RESULTS: Base digestion and filtration yielded acceptable recoveries: 90 ± 11 % for polystyrene (PS), 93 ± 16 % for polyethylene (PE), and 53 ± 18 % for polypropylene (PP). Limit of Detections (LODs) ranged from 0.15 to 0.60 μg/mL, depending on the polymer. Placental blood samples were collected from 46 donors and analyzed in triplicate, resulting in measurements for 138 samples. Forty-three samples contained at least one polymer type above the limit of detection, and 10 samples contained at least one polymer type above the limit of quantification. Total plastic concentration in samples with detectable levels (>LOD) of MNPs averaged 0.9 μg/mL and ranged between 0.2 and 3.6 μg/mL. Orthogonal separation by ion mobility revealed that 10/22 PE detections were false positives. SIGNIFICANCE: This study is the first to integrate ion mobility separation to differentiate between genuine and false detection of PE in human blood. Without the aid of ion mobility separation, the concentration of PE in individual samples was overestimated by up to 233 % of the mean MNP concentration, underlining the importance of multidimensional separation for individual exposure analysis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PlacentaMicroplasticsHumansFemaleGas Chromatography-Mass SpectrometryPregnancyPyrolysisIon Mobility SpectrometryLimit of Detection

Stichwörter der Autor:innen

Ion mobility-mass spectrometryMicroplasticsMultidimensional separationNanoplasticsPyrolysis gas chromatography

Substanzen

Microplastics

Autor:innen und Institutionen

  • Department of Chemistry, Memorial University of Newfoundland, 45 Arctic Ave., St. John's, Newfoundland and Labrador, Canada.
  • Chemistry for Environment and Health, Amsterdam Institute for Life and Environment (A-LIFE), Vrije Universiteit Amsterdam, Amsterdam, the Netherlands.
  • Department of Chemistry, Memorial University of Newfoundland, 45 Arctic Ave., St. John's, Newfoundland and Labrador, Canada; KWR Water Research Institute, P.O. Box 1072, Nieuwegein, 3430 BB, the Netherlands.
  • Department of Chemistry, Memorial University of Newfoundland, 45 Arctic Ave., St. John's, Newfoundland and Labrador, Canada. Electronic address: kjobst@mun.ca.

Förderung

  • Health Canada
  • Natural Sciences and Engineering Research Council of Canada
  • Canada Foundation for Innovation
  • Janeway Children's Hospital Foundation

Zitieren

APA

Bissonnette, J. R., Harvey, N. E., Rowsell, M. L., Kiefte, S., Houthuijs, K. J., Béen, F. M., Lamoree, M. H., Cahill, L. S., & Jobst, K. J. (2025). Identification of micro-/nanoplastics in human placental blood using comprehensive multidimensional pyrolysis - gas chromatography x ion mobility mass spectrometry. Analytica Chimica Acta, 1376, 344606. https://doi.org/10.1016/j.aca.2025.344606

Vancouver

Bissonnette JR, Harvey NE, Rowsell ML, Kiefte S, Houthuijs KJ, Béen FM, et al. Identification of micro-/nanoplastics in human placental blood using comprehensive multidimensional pyrolysis - gas chromatography x ion mobility mass spectrometry. Analytica Chimica Acta. 2025;1376:344606. doi:10.1016/j.aca.2025.344606

BibTeX
@article{Bissonnette2025,
  author = {Bissonnette, Justine R and Harvey, Nikita E and Rowsell, Mikela L and Kiefte, Sophie and Houthuijs, Kas J and Béen, Frederic M and Lamoree, Marja H and Cahill, Lindsay S and Jobst, Karl J},
  title = {Identification of micro-/nanoplastics in human placental blood using comprehensive multidimensional pyrolysis - gas chromatography x ion mobility mass spectrometry},
  journal = {Analytica Chimica Acta},
  year = {2025},
  volume = {1376},
  pages = {344606},
  doi = {10.1016/j.aca.2025.344606}
}
Kostenlos starten →