EUVIMEDEUVIMED entdecken
Crossref

Comprehensive evaluation of dual-mode LC-MS conditions for enhanced metabolomic profiling: Application to microplastic exposure studies

Kuan-Lu Wu, Pei-Chen Lin, Wei-Chen Lin, Sung-Fang Chen

Analytica Chimica Acta · 2025-09 · 1367 · 344313

DOI: 10.1016/j.aca.2025.344313 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2025-09. Verfasst von Kuan-Lu Wu und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, National Taiwan Normal University, Taipei, 11677, Taiwan. Hauptthemen laut MEDLINE: Metabolomics, Microplastics. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: National Science and Technology Council, Ministry of Science and Technology, Taiwan.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Polystyrene microplastics (PS-MPs) are emerging contaminants of concern due to their potential health impacts and widespread presence in the environment. Metabolomics offers a powerful approach to investigate biological responses to such exposures. However, current LC-MS methods are often limited by the suitability of chromatographic conditions for metabolites with diverse physicochemical properties, leading to suboptimal coverage and analytical redundancy. This study addresses these limitations by establishing a robust, broadly applicable dual-mode LC-MS strategy to improve coverage and analytical efficiency in microplastic exposure studies. This study evaluated 18 chromatographic conditions using six commercial columns including amide, silica, Obelisc N, C18, pentafluoophenyl (F5), and cyanopropyl (CN), to optimize metabolite separation in both positive and negative electrospray ionization (ESI) modes. Mouse large intestine extracts exposed to PS-MPs showed broad metabolome coverage under optimized conditions. In positive mode, the amide column with ammonium acetate/acetic acid (AmAc/AcA) effectively captured diverse polar metabolites. In negative mode, the F5 column with ammonium formate/formic acid (AmF/FA) excelled in phospholipid detection and lipid separation. Combining these conditions enabled complementary profiling with minimal overlap. Additionally, 42 differential metabolites affected by PS-MPs were associated with key metabolic pathways, including amino acid, taurine, hypotaurine, and glutathione metabolism. This optimized, high-coverage LC-MS strategy provides a novel analytical framework that maximizes metabolome profiling efficiency and minimizes sample input. It improves detection of diverse metabolite classes and supports robust biological interpretation, offering broad applicability for future studies on environmental exposures and complex biological challenges.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MetabolomicsMicroplasticsAnimalsMiceChromatography, LiquidMetabolomeMass SpectrometryLiquid Chromatography-Mass Spectrometry

Stichwörter der Autor:innen

Liquid chromatographyMass spectrometryMetabolomics

Substanzen

Microplastics

Autor:innen und Institutionen

  • Department of Chemistry, National Taiwan Normal University, Taipei, 11677, Taiwan.
  • Department of Chemistry, National Taiwan Normal University, Taipei, 11677, Taiwan. Electronic address: sfchen@ntnu.edu.tw.

Förderung

  • National Science and Technology Council
  • Ministry of Science and Technology, Taiwan

Zitieren

APA

Wu, K. L., Lin, P. C., Lin, W. C., & Chen, S. F. (2025). Comprehensive evaluation of dual-mode LC-MS conditions for enhanced metabolomic profiling: Application to microplastic exposure studies. Analytica Chimica Acta, 1367, 344313. https://doi.org/10.1016/j.aca.2025.344313

Vancouver

Wu KL, Lin PC, Lin WC, Chen SF. Comprehensive evaluation of dual-mode LC-MS conditions for enhanced metabolomic profiling: Application to microplastic exposure studies. Analytica Chimica Acta. 2025;1367:344313. doi:10.1016/j.aca.2025.344313

BibTeX
@article{Wu2025,
  author = {Wu, Kuan-Lu and Lin, Pei-Chen and Lin, Wei-Chen and Chen, Sung-Fang},
  title = {Comprehensive evaluation of dual-mode LC-MS conditions for enhanced metabolomic profiling: Application to microplastic exposure studies},
  journal = {Analytica Chimica Acta},
  year = {2025},
  volume = {1367},
  pages = {344313},
  doi = {10.1016/j.aca.2025.344313}
}
Kostenlos starten →