EUVIMEDEUVIMED entdecken
Crossref

Novel strategy for screening aptamers of Staphylococcus aureus enterotoxin A based on active fragments and fusion design

Shujing Ge, Mengyao Guan, Fei Pan, Yanli Wang, Daodong Pan, Chaoying Zhang, Xinchang Gao, Yali Dang

Analytica Chimica Acta · 2025-07 · 1360 · 344135

DOI: 10.1016/j.aca.2025.344135 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2025-07. Verfasst von Shujing Ge und 7 weiteren Autor:innen. Beteiligte Einrichtung: Zhejiang Key Laboratory of Intelligent Food Logistic and Processing, College of Food Science and Engineering, Ningbo University, Ningbo, 315211, Chin…. Hauptthemen laut MEDLINE: Enterotoxins, Aptamers, Nucleotide, Staphylococcus aureus, Biosensing Techniques. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 56 Literaturangaben. Gefördert von: Ningbo University, Science and Technology Department of Zhejiang Province, Department of Agriculture and Rural Affairs of Zhejiang Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Staphylococcus aureus enterotoxin A (SEA) is the major toxin responsible for food poisoning caused by Staphylococcus aureus infection. Aptamers are an ideal solution for visual detection of SEA. However, screening for aptamers is generally expensive and time-consuming. Therefore, a new method for efficient screening of high-affinity SEA aptamers needs to be established and supplemented with smartphone image recognition to enable visual and rapid detection of SEA. RESULTS: A new aptamer for sensitive detection of SEA was screened using active fragments and fusion design. The novel high-affinity aptamer (BX1) was derived by intercepting active nucleotide fragments of several aptamers and fusing them; it was verified to have high affinity, with a Kd value of 4.16 ± 0.22 nM. Molecular dynamic simulation illustrated that BX1 formed a stable complex conformation with SEA, which maintained its stability for 200 ns. This novel aptamer can be used for visual inspection of SEA. A smartphone-assisted aptasensor was designed to sensitively detect SEA in milk with a wide linear range (1-250 ng/mL), low detection limit (0.42 ng/mL), and satisfactory spiked recovery. SIGNIFICANCE: A new method for screening SEA aptamers based on active fragments and fusion design was developed, which can rapidly screen high-affinity aptamers in a short duration and at a low expenditure. In addition, a new strategy for the rapid detection of SEA using a smartphone-assisted colorimetric aptamer sensor was successfully applied. This research method may provide a reference for the highly sensitive detection of other biotoxins.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

EnterotoxinsAptamers, NucleotideStaphylococcus aureusBiosensing TechniquesMilkMolecular Dynamics SimulationLimit of DetectionAnimalsSmartphone

Stichwörter der Autor:innen

Active fragmentAptasensorFusion designMolecular dockingMolecular dynamic simulation

Substanzen

EnterotoxinsAptamers, Nucleotideenterotoxin A, Staphylococcal

Autor:innen und Institutionen

  • Zhejiang Key Laboratory of Intelligent Food Logistic and Processing, College of Food Science and Engineering, Ningbo University, Ningbo, 315211, China.
  • State Key Laboratory of Resource Insects, Institute of Apicultural Research, Chinese Academy of Agricultural Sciences, Beijing, 100093, China.
  • Department of Quality and Safety, Chinese Academy of Fishery Sciences, Beijing, 100141, China. Electronic address: cyzhang0317@cafs.ac.cn.
  • Institute of Drug Discovery Technology, Ningbo University, Ningbo, 315211, China. Electronic address: gaoxinchang@nbu.edu.cn.
  • Zhejiang Key Laboratory of Intelligent Food Logistic and Processing, College of Food Science and Engineering, Ningbo University, Ningbo, 315211, China. Electronic address: dangyali@nbu.edu.cn.

Förderung

  • Ningbo University
  • Science and Technology Department of Zhejiang Province
  • Department of Agriculture and Rural Affairs of Zhejiang Province

Zitieren

APA

Ge, S., Guan, M., Pan, F., Wang, Y., Pan, D., Zhang, C., Gao, X., & Dang, Y. (2025). Novel strategy for screening aptamers of Staphylococcus aureus enterotoxin A based on active fragments and fusion design. Analytica Chimica Acta, 1360, 344135. https://doi.org/10.1016/j.aca.2025.344135

Vancouver

Ge S, Guan M, Pan F, Wang Y, Pan D, Zhang C, et al. Novel strategy for screening aptamers of Staphylococcus aureus enterotoxin A based on active fragments and fusion design. Analytica Chimica Acta. 2025;1360:344135. doi:10.1016/j.aca.2025.344135

BibTeX
@article{Ge2025,
  author = {Ge, Shujing and Guan, Mengyao and Pan, Fei and Wang, Yanli and Pan, Daodong and Zhang, Chaoying and Gao, Xinchang and Dang, Yali},
  title = {Novel strategy for screening aptamers of Staphylococcus aureus enterotoxin A based on active fragments and fusion design},
  journal = {Analytica Chimica Acta},
  year = {2025},
  volume = {1360},
  pages = {344135},
  doi = {10.1016/j.aca.2025.344135}
}
Kostenlos starten →