Smartphone-assisted dual-sided capillary microfluidic device for multiplex detection of heavy metals and nutrients in drinking water
Analytica Chimica Acta · 2025-06 · 1356 · 344031
DOI: 10.1016/j.aca.2025.344031 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2025-06. Verfasst von Pornchanok Punnoy und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Materials Science, Faculty of Science, Chulalongkorn University, Soi Chula12, Phayathai Road, Pathumwan, Bangkok, 10330, Thailand. Hauptthemen laut MEDLINE: Smartphone, Drinking Water, Metals, Heavy, Water Pollutants, Chemical. Die Arbeit wurde bisher 34-mal zitiert (Crossref) und nennt 71 Literaturangaben. Gefördert von: US Army Combat Capabilities Development Command, Thailand Science Research and Innovation, Chulalongkorn University.
Abstract (Originalsprache)
BACKGROUND: Heavy metal and nutrient contamination are growing global issues necessitating monitoring water resources. While laboratory-based platforms for detecting these contaminants are sensitive and accurate, they require centralized facilities, trained personnel, and significant costs. Microfluidic paper-based analytical devices have emerged as a low-cost alternative for on-site detection of these water contaminants; however, these platforms struggle with slow assay times, loss of analyte, and the need for precise volumetric pipetting. Moreover, these platforms often focus on detecting only one subgroup of contaminants, limiting the potential for comprehensive measurements. RESULTS: We developed a capillary flow-driven, single-dip dual-sided detection system, enabling rapid, multiplex detection of heavy metals and nutrients in a single user step. The sensor enables both qualitative visual analysis and quantitative analysis via a smartphone app for real-time and on-site detection of Ni, Fe, Cu, NO2- and PO43-. The limits of detection (LoD) and quantification (LoQ) were calculated as 1.3 and 4.4 ppm for Ni, 0.3 and 0.9 ppm for Fe, 0.2 and 0.6 ppm for Cu, 0.4 and 1.2 ppm for NO2-, and 0.5 and 1.6 ppm for PO43-. Selectivity was achieved through masking strategies in each detection zone. The sensors were stable for >4 weeks under ambient conditions. Spike-recovery analysis was performed using river, tap, pond, and commercial drinking water, achieving recoveries between 86 and 112 % with accuracy and precision below 15 % RSD for all samples. SIGNIFICANCE: This multiplex sensor offers a solution to overcome the current limitations of paper-based devices, allowing for a more comprehensive analysis of multiple contaminant classes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Materials Science, Faculty of Science, Chulalongkorn University, Soi Chula12, Phayathai Road, Pathumwan, Bangkok, 10330, Thailand.
- Department of Chemistry, Colorado State University, Fort Collins, CO, 80523, United States.
- U.S. Army Combat Capabilities Development Command (DEVCOM)─Soldier Center, 10 General Greene Avenue, Natick, MA, 01760, United States.
- Metallurgy and Materials Science Research Institute, Chulalongkorn University, Soi Chula12, Phayathai Road, Pathumwan, Bangkok, 10330, Thailand; Center of Excellence in Responsive Wearable Materials, Chulalongkorn Unive…
- Department of Materials Science, Faculty of Science, Chulalongkorn University, Soi Chula12, Phayathai Road, Pathumwan, Bangkok, 10330, Thailand; Center of Excellence in Responsive Wearable Materials, Chulalongkorn Unive…
- Department of Chemistry, Colorado State University, Fort Collins, CO, 80523, United States. Electronic address: Chuck.henry@colostate.edu.
Förderung
- US Army Combat Capabilities Development Command
- Thailand Science Research and Innovation
- Chulalongkorn University
- International Technology Center Pacific
Zitieren
APA
Punnoy, P., Aryal, P., Hefner, C. E., Brack, E., Rodthongkum, N., Potiyaraj, P., & Henry, C. S. (2025). Smartphone-assisted dual-sided capillary microfluidic device for multiplex detection of heavy metals and nutrients in drinking water. Analytica Chimica Acta, 1356, 344031. https://doi.org/10.1016/j.aca.2025.344031
Vancouver
Punnoy P, Aryal P, Hefner CE, Brack E, Rodthongkum N, Potiyaraj P, et al. Smartphone-assisted dual-sided capillary microfluidic device for multiplex detection of heavy metals and nutrients in drinking water. Analytica Chimica Acta. 2025;1356:344031. doi:10.1016/j.aca.2025.344031
BibTeX
@article{Punnoy2025,
author = {Punnoy, Pornchanok and Aryal, Prakash and Hefner, Claire E and Brack, Eric and Rodthongkum, Nadnudda and Potiyaraj, Pranut and Henry, Charles S},
title = {Smartphone-assisted dual-sided capillary microfluidic device for multiplex detection of heavy metals and nutrients in drinking water},
journal = {Analytica Chimica Acta},
year = {2025},
volume = {1356},
pages = {344031},
doi = {10.1016/j.aca.2025.344031}
}
EUVIMED