Systematic characterisation of microplastics released from disposable medical devices using laser direct infrared spectroscopy
Analytica Chimica Acta · 2025-06 · 1355 · 343982
DOI: 10.1016/j.aca.2025.343982 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2025-06. Verfasst von Chuanfeng Chen und 5 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Population Health Across Life Cycle, MOE, School of Public Health, Anhui Medical University, Hefei, 230032, China. Hauptthemen laut MEDLINE: Microplastics, Lasers, Disposable Equipment. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: Anhui Province Department of Education.
Abstract (Originalsprache)
BACKGROUND: Human exposure to microplastics (MPs) is widespread, attracting significant attention from both the public and the scientific community. Although several direct and indirect exposure pathways have been investigated, the extent of MP exposure from disposable medical devices remains poorly understood and warrants further research. RESULTS: This work indicates that many MPs (10-30 μm) were released during the simulated use of disposable medical devices. Two common medical devices-disposable infusion tubes and blood needles-were selected as the research subjects. Analysis utilizing laser direct infrared (LDIR) revealed that plastic released from infusion tubes primarily consisted of polyamide (PA), polyvinyl chloride (PVC), and polyethene terephthalate (PET), with an average total number (ATN) of 11.8 particles/mL. MPs released from blood collection needles mainly consisted of polyurethane (PU) and PET, with an ATN of 82.7 particles/mL. For a 0.9 % normal saline, the ATN released from the infusion tubes during the stimulating infusion scenario at room temperature (4 h) was approximately 16 particles/mL, primarily consisting of PA, PVC, and PET. Additionally, the release of MPs increased with rising temperatures. Under the same conditions, ATN release from the blood collection needles was approximately 84.4 particles/mL, mainly from PA, PVC, and PU. SIGNIFICANCE: This implies that MPs can enter the bloodstream directly through infusion tubes and blood collection needles, highlighting the need for greater attention to the risk of patient exposure.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Key Laboratory of Population Health Across Life Cycle, MOE, School of Public Health, Anhui Medical University, Hefei, 230032, China.
- Key Laboratory of Population Health Across Life Cycle, MOE, School of Public Health, Anhui Medical University, Hefei, 230032, China. Electronic address: 2022500064@ahmu.edu.cn.
Förderung
- Anhui Province Department of Education
Zitieren
APA
Chen, C., Du, S., Liu, Z., Li, W., Tao, F., & Qie, X. (2025). Systematic characterisation of microplastics released from disposable medical devices using laser direct infrared spectroscopy. Analytica Chimica Acta, 1355, 343982. https://doi.org/10.1016/j.aca.2025.343982
Vancouver
Chen C, Du S, Liu Z, Li W, Tao F, Qie X. Systematic characterisation of microplastics released from disposable medical devices using laser direct infrared spectroscopy. Analytica Chimica Acta. 2025;1355:343982. doi:10.1016/j.aca.2025.343982
BibTeX
@article{Chen2025,
author = {Chen, Chuanfeng and Du, Shanshan and Liu, Ziyan and Li, Wenfei and Tao, Fangbiao and Qie, Xuejiao},
title = {Systematic characterisation of microplastics released from disposable medical devices using laser direct infrared spectroscopy},
journal = {Analytica Chimica Acta},
year = {2025},
volume = {1355},
pages = {343982},
doi = {10.1016/j.aca.2025.343982}
}
EUVIMED