EUVIMEDEUVIMED entdecken
Crossref

Study on precise identification of remote bacterial species using multi-temporal LIBS optimized by plasma electron temperature coefficient of variation

Jiahui Liang, Fei Chen, Zhihui Tian, Yan Zhang, Lei Zhang, Wangbao Yin, Liantuan Xiao, Suotang Jia

Analytica Chimica Acta · 2025

DOI: 10.1016/j.aca.2025.343929 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2025. Verfasst von Jiahui Liang und 7 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Quantum Optics and Quantum Optics Devices, Institute of Laser Spectroscopy, Shanxi University, Taiyuan, China; Collaborative …. Hauptthemen laut MEDLINE: Temperature, Bacteria, Lasers, Spectrum Analysis. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Higher Education Discipline Innovation Project, National Key Research and Development Program of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Laser-Induced Breakdown Spectroscopy (LIBS) has demonstrated significant potential in microbial detection due to its rapid, non-contact, and multi-element analytical capabilities. However, remote detection is hindered by challenges such as signal attenuation and the high similarity of spectral features, which reduce classification accuracy. To address these issues, this study proposes a multi-temporal LIBS remote identification method optimized based on the plasma electron temperature coefficient of variation (CVT). By analyzing CVT values across different delay ranges, optimal time delays were selected and combined to amplify spectral differentiation, thereby improving classification performance. RESULTS: A coaxial-design LIBS telemetry system with adjustable focus was constructed, and multi-substrate telemetry testing was conducted on 10 common pathogenic bacteria at distances of 5 m and 10 m. By optimizing multiple temporal delays within the 100-1000 ns range, the classification performance of single-temporal, dual-temporal, and multi-temporal spectral combinations was evaluated. The results showed that the multi-temporal approach improved the classification performance across all substrates. At a distance of 5 m, a 100 % identification rate was achieved for all substrates, with Precision, Recall, and F1-score all reaching 1.0. At 10 m, the identification rate for the aluminum substrate increased from 76 % to 93 %. In addition, the contribution of the four major elements, Ca, Na, C, and K, was found to account for up to 60 % of the classification results. SIGNIFICANCE AND NOVELTY: It is demonstrated that the CVT-optimized multi-temporal LIBS technology effectively overcomes the signal attenuation bottleneck at long distances, significantly enhancing the robustness and analytical capability of remote microbial identification. This approach provides a novel method for remote detection in areas such as public safety, medical diagnostics, and military defense.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TemperatureBacteriaLasersSpectrum AnalysisElectrons

Stichwörter der Autor:innen

Bacterial identificationLaser-induced breakdown spectroscopy (LIBS)Multi-temporalRemote detectionTemperature coefficient of variation

Autor:innen und Institutionen

  • State Key Laboratory of Quantum Optics and Quantum Optics Devices, Institute of Laser Spectroscopy, Shanxi University, Taiyuan, China; Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan, China.
  • School of Physics and Electronic Information Engineering, Hubei Engieering University, Xiaogan, 432000, China.
  • School of Optoelectronic Engineering, Xi'an Technological University, Xian, China.
  • State Key Laboratory of Quantum Optics and Quantum Optics Devices, Institute of Laser Spectroscopy, Shanxi University, Taiyuan, China; Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan, China…

Förderung

  • National Natural Science Foundation of China
  • Higher Education Discipline Innovation Project
  • National Key Research and Development Program of China
  • Hubei Provincial Department of Education

Zitieren

APA

Liang, J., Chen, F., Tian, Z., Zhang, Y., Zhang, L., Yin, W., Xiao, L., & Jia, S. (2025). Study on precise identification of remote bacterial species using multi-temporal LIBS optimized by plasma electron temperature coefficient of variation. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2025.343929

Vancouver

Liang J, Chen F, Tian Z, Zhang Y, Zhang L, Yin W, et al. Study on precise identification of remote bacterial species using multi-temporal LIBS optimized by plasma electron temperature coefficient of variation. Analytica Chimica Acta. 2025. doi:10.1016/j.aca.2025.343929

BibTeX
@article{Liang2025,
  author = {Liang, Jiahui and Chen, Fei and Tian, Zhihui and Zhang, Yan and Zhang, Lei and Yin, Wangbao and Xiao, Liantuan and Jia, Suotang},
  title = {Study on precise identification of remote bacterial species using multi-temporal LIBS optimized by plasma electron temperature coefficient of variation},
  journal = {Analytica Chimica Acta},
  year = {2025},
  doi = {10.1016/j.aca.2025.343929}
}
Kostenlos starten →