A gold nanoflower particle-based immunochromatographic assay sensor for on-site detection of six species of Salmonella in water and food samples
Analytica Chimica Acta · 2025-05 · 1350 · 343813
DOI: 10.1016/j.aca.2025.343813 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2025-05. Verfasst von Yinglin Wang und 5 weiteren Autor:innen. Beteiligte Einrichtung: College of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, 200093, PR China. Hauptthemen laut MEDLINE: Salmonella, Gold, Metal Nanoparticles, Food Microbiology. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: National Key Research and Development Program of China.
Abstract (Originalsprache)
BACKGROUND: Salmonella is a prevalent zoonotic pathogen that threatens food safety and human health. Owing to the large number of Salmonella species and their significant variations in pathogenicity and virulence, it is difficult to classify Salmonella strains quickly, which makes rapid detection of Salmonella outbreaks and research on foodborne diseases difficult. RESULTS: Therefore, in this study, an ICA sensor for the detection of multiple Salmonella strains with high pathogenicity based on broad-spectrum Salmonella antibodies was developed using AuNFs as probes. Compared with other Salmonella ICA sensors, the sensor was able to detect six different types of Salmonella. The ICA sensor had a visual LOD of 104 CFU/mL for S. Paratyphi A, S. Typhimurium, S. Paratyphi B, S. Saintpaul, S. Heidelberg and S. enterica. The ICA sensor had no cross-reaction with 20 common foodborne pathogens, which could effectively avoid incorrect results caused by cross-reaction and delay accurate tracing of pathogenic bacteria. Moreover, the feasibility of the ICA sensor was verified by detecting Salmonella in spiked drinking water, orange juice, and milk. The ICA sensor achieved a visual detection limit of 104 CFU/mL and detected as low as 1 CFU/mL in chicken and egg samples after 6-8 h of enrichment. SIGNIFICANCE: In conclusion, this sensor offers a rapid, cost-effective, and reliable solution for the on-site detection of multiple Salmonella strains, addressing critical needs in food safety and public health.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- College of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, 200093, PR China.
- College of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, 200093, PR China. Electronic address: liuq@usst.edu.cn.
Förderung
- National Key Research and Development Program of China
Zitieren
APA
Wang, Y., Wu, Y., Wu, Y., Feng, Z., Li, D., & Liu, Q. (2025). A gold nanoflower particle-based immunochromatographic assay sensor for on-site detection of six species of Salmonella in water and food samples. Analytica Chimica Acta, 1350, 343813. https://doi.org/10.1016/j.aca.2025.343813
Vancouver
Wang Y, Wu Y, Wu Y, Feng Z, Li D, Liu Q. A gold nanoflower particle-based immunochromatographic assay sensor for on-site detection of six species of Salmonella in water and food samples. Analytica Chimica Acta. 2025;1350:343813. doi:10.1016/j.aca.2025.343813
BibTeX
@article{Wang2025,
author = {Wang, Yinglin and Wu, Yafang and Wu, Youxue and Feng, Zhaoyi and Li, Dezhi and Liu, Qing},
title = {A gold nanoflower particle-based immunochromatographic assay sensor for on-site detection of six species of Salmonella in water and food samples},
journal = {Analytica Chimica Acta},
year = {2025},
volume = {1350},
pages = {343813},
doi = {10.1016/j.aca.2025.343813}
}
EUVIMED