A novel fluorometric and colorimetric dual-mode sensor for AMI early diagnosis based on an ultrathin Fe-MOF-74 nanosheet with peroxidase mimic activity and fluorescence properties
Analytica Chimica Acta · 2025
DOI: 10.1016/j.aca.2025.343800 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2025. Verfasst von Jinyan Liu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Prevention and Treatment of Cardiovascular and Cerebrovascular Diseases, Ministry of Education, Key Laboratory for Tissue Engineeri…. Hauptthemen laut MEDLINE: Colorimetry, Metal-Organic Frameworks, Nanostructures, Peroxidase. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 37 Literaturangaben. Gefördert von: Gannan Medical University, Innovation and Technology Commission, Hong Kong Polytechnic University.
Abstract (Originalsprache)
BACKGROUND: Cardiac troponin I (cTnI) is a crucial diagnosis biomarker for acute myocardial infarction (AMI). Early accurate determination of the concentration of cTnI significantly decreases the death rate of AMI. Compared with classic methods, dual-mode sensors for cTnI determination could help reduce the false positive rate. RESULT: In this work, an ultrathin Fe-MOF-74 nanosheet with fluorescence properties and peroxidase mimic activity was synthesized for the first time. Applying this nanosheet, a novel dual-mode sensor was developed to quantify cTnI in human serum. The ultrathin Fe-MOF-74 nanosheets catalyze the decomposition of hydrogen peroxide produced by glucose oxidase (GOx)-triggered enzyme-linked immunosorbent assay (ELISA) applying cTnI as an antigen target, to generate reactive oxygen species (ROS). 3,3',5,5'-tetramethylbenzidine (TMB) can be oxidized by the generated free radicals, which simultaneously lead to the fluorescence quench of Fe-MOF-74 due to the inner filter effect (IFE). The correlation between the morphology of Fe-MOF-74 and its fluorescence intensity and peroxidase mimic activity was also investigated. SIGNIFICANCE: The sensors exhibited linearity with the concentration of cTnI in 10-2000 pg mL-1 in both the fluorescence and visual mode with the detection limit of 6.4 pg mL-1 and 8.4 pg mL-1, respectively. It presenting good selectivity and anti-interference ability, can provide accurate and precise results in testing the concentration of cTnI in serum samples from patients in hospitals. It could be applied in the early diagnosis of AMI to reduce the incidence, disability, and mortality rates.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Key Laboratory of Prevention and Treatment of Cardiovascular and Cerebrovascular Diseases, Ministry of Education, Key Laboratory for Tissue Engineering of Jiangxi Province, School of Medical and Information Engineering,…
- The State Key Laboratory of Chemical Biology and Drug Discovery, Department of Applied Biology and Chemical Technology, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong SAR, China. Electronic address:…
- Ministry of Education Key Laboratory of Analytical Science of Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection for Food Safety, Fuzhou University, Fuzhou, Fujian, 350108, PR China. Ele…
- The State Key Laboratory of Chemical Biology and Drug Discovery, Department of Applied Biology and Chemical Technology, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong SAR, China.
Förderung
- Gannan Medical University
- Innovation and Technology Commission
- Hong Kong Polytechnic University
- Ministry of Science and Technology of the People's Republic of China
- Jiangxi Provincial Natural Science Foundation
- Ministry of Education
Zitieren
APA
Liu, J., Wang, Y., Peng, W., Qiu, B., Wong, K. Y., & Hu, S. (2025). A novel fluorometric and colorimetric dual-mode sensor for AMI early diagnosis based on an ultrathin Fe-MOF-74 nanosheet with peroxidase mimic activity and fluorescence properties. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2025.343800
Vancouver
Liu J, Wang Y, Peng W, Qiu B, Wong KY, Hu S. A novel fluorometric and colorimetric dual-mode sensor for AMI early diagnosis based on an ultrathin Fe-MOF-74 nanosheet with peroxidase mimic activity and fluorescence properties. Analytica Chimica Acta. 2025. doi:10.1016/j.aca.2025.343800
BibTeX
@article{Liu2025,
author = {Liu, Jinyan and Wang, Yong and Peng, Weijie and Qiu, Bin and Wong, Kwok-Yin and Hu, Shuisheng},
title = {A novel fluorometric and colorimetric dual-mode sensor for AMI early diagnosis based on an ultrathin Fe-MOF-74 nanosheet with peroxidase mimic activity and fluorescence properties},
journal = {Analytica Chimica Acta},
year = {2025},
doi = {10.1016/j.aca.2025.343800}
}
EUVIMED