Facile preparation of iridium-based AIE polymer dots for sensitive electrochemiluminescence immunoassay of CD44 protein
Analytica Chimica Acta · 2025-03 · 1341 · 343639
DOI: 10.1016/j.aca.2025.343639 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2025-03. Verfasst von Dehao Jia und 6 weiteren Autor:innen. Beteiligte Einrichtung: College of Biological and Chemical Engineering, Qilu Institute of Technology, Jinan, 250200, PR China; Key Laboratory of Interfacial Reaction & Sensi…. Hauptthemen laut MEDLINE: Iridium, Electrochemical Techniques, Luminescent Measurements, Polymers. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 47 Literaturangaben. Gefördert von: Shandong Province Natural Science Foundation, National Natural Science Foundation of China.
Abstract (Originalsprache)
The development of aggregation-induced emission (AIE) luminophores is a fascinating and promising topic in electrochemiluminescence (ECL) bioanalysis. Herein, the AIE-active but water-insoluble [Ir(bt)₂(acac)] (bt = 2-phenylbenzothiazole, acac = acetylacetonate) was encapsulated within poly(styrene-maleic anhydride) (PSMA) using a simple nanoprecipitation method. This encapsulation strategy could effectively limit the free motion of Ir(bt)₂(acac) and trigger the aggregation-induced electrochemiluminescence (AIECL) effect. The water dispersibility and ECL intensity of Ir(bt)₂(acac)-polymer dots (IrPdots) were greatly improved compared to equivalent amounts of Ir(bt)₂(acac) alone. More importantly, unlike Ir(bt)₂(acac), the IrPdots possess carboxyl groups, allowing them to be conjugated with biomolecules for bioanalytical applications. Consequently, a sandwich ECL immunosensor for the sensitive detection of CD44 was constructed using the prepared IrPdots-labeled detection antibody (Ab2) as the ECL probe and polyaniline nanorods (PANI NRs) as the substrate that provided a large electroactive surface for immobilizing capture antibody (Ab1). Under optimized experimental conditions, a good linear relationship was observed between the logarithm of ECL intensity and the CD44 concentration, ranging from 0.1 pg/mL to 50 ng/mL, with a detection limit as low as 77 fg/mL. This work introduces a method for the preparation of Pdots containing AIE-active cyclometallated iridium complexes, potentially broadening the application of these water-insoluble but highly AIE-active iridium complexes in aqueous bioassays.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- College of Biological and Chemical Engineering, Qilu Institute of Technology, Jinan, 250200, PR China; Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemi…
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China.
- College of Biological and Chemical Engineering, Qilu Institute of Technology, Jinan, 250200, PR China. Electronic address: gaoxing620@126.com.
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China. Electronic address: yanglei_19940831@163…
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China; Department of Chemistry, Sungkyunkwan Un…
Förderung
- Shandong Province Natural Science Foundation
- National Natural Science Foundation of China
Zitieren
APA
Jia, D., Hua, Y., Wu, T., Ren, X., Gao, X., Yang, L., & Wei, Q. (2025). Facile preparation of iridium-based AIE polymer dots for sensitive electrochemiluminescence immunoassay of CD44 protein. Analytica Chimica Acta, 1341, 343639. https://doi.org/10.1016/j.aca.2025.343639
Vancouver
Jia D, Hua Y, Wu T, Ren X, Gao X, Yang L, et al. Facile preparation of iridium-based AIE polymer dots for sensitive electrochemiluminescence immunoassay of CD44 protein. Analytica Chimica Acta. 2025;1341:343639. doi:10.1016/j.aca.2025.343639
BibTeX
@article{Jia2025,
author = {Jia, Dehao and Hua, Yunhui and Wu, Tingting and Ren, Xiang and Gao, Xing and Yang, Lei and Wei, Qin},
title = {Facile preparation of iridium-based AIE polymer dots for sensitive electrochemiluminescence immunoassay of CD44 protein},
journal = {Analytica Chimica Acta},