EUVIMEDEUVIMED entdecken
Crossref

Facile preparation of iridium-based AIE polymer dots for sensitive electrochemiluminescence immunoassay of CD44 protein

Dehao Jia, Yunhui Hua, Tingting Wu, Xiang Ren, Xing Gao, Lei Yang, Qin Wei

Analytica Chimica Acta · 2025-03 · 1341 · 343639

DOI: 10.1016/j.aca.2025.343639 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2025-03. Verfasst von Dehao Jia und 6 weiteren Autor:innen. Beteiligte Einrichtung: College of Biological and Chemical Engineering, Qilu Institute of Technology, Jinan, 250200, PR China; Key Laboratory of Interfacial Reaction & Sensi…. Hauptthemen laut MEDLINE: Iridium, Electrochemical Techniques, Luminescent Measurements, Polymers. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 47 Literaturangaben. Gefördert von: Shandong Province Natural Science Foundation, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The development of aggregation-induced emission (AIE) luminophores is a fascinating and promising topic in electrochemiluminescence (ECL) bioanalysis. Herein, the AIE-active but water-insoluble [Ir(bt)₂(acac)] (bt = 2-phenylbenzothiazole, acac = acetylacetonate) was encapsulated within poly(styrene-maleic anhydride) (PSMA) using a simple nanoprecipitation method. This encapsulation strategy could effectively limit the free motion of Ir(bt)₂(acac) and trigger the aggregation-induced electrochemiluminescence (AIECL) effect. The water dispersibility and ECL intensity of Ir(bt)₂(acac)-polymer dots (IrPdots) were greatly improved compared to equivalent amounts of Ir(bt)₂(acac) alone. More importantly, unlike Ir(bt)₂(acac), the IrPdots possess carboxyl groups, allowing them to be conjugated with biomolecules for bioanalytical applications. Consequently, a sandwich ECL immunosensor for the sensitive detection of CD44 was constructed using the prepared IrPdots-labeled detection antibody (Ab2) as the ECL probe and polyaniline nanorods (PANI NRs) as the substrate that provided a large electroactive surface for immobilizing capture antibody (Ab1). Under optimized experimental conditions, a good linear relationship was observed between the logarithm of ECL intensity and the CD44 concentration, ranging from 0.1 pg/mL to 50 ng/mL, with a detection limit as low as 77 fg/mL. This work introduces a method for the preparation of Pdots containing AIE-active cyclometallated iridium complexes, potentially broadening the application of these water-insoluble but highly AIE-active iridium complexes in aqueous bioassays.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

IridiumElectrochemical TechniquesLuminescent MeasurementsPolymersHyaluronan ReceptorsQuantum DotsImmunoassayHumansLimit of Detection

Stichwörter der Autor:innen

Aggregation-induced emissionBiomarkerElectrochemiluminescenceImmunosensorIridium complex

Substanzen

IridiumPolymersHyaluronan ReceptorsCD44 protein, human

Autor:innen und Institutionen

  • College of Biological and Chemical Engineering, Qilu Institute of Technology, Jinan, 250200, PR China; Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemi…
  • Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China.
  • College of Biological and Chemical Engineering, Qilu Institute of Technology, Jinan, 250200, PR China. Electronic address: gaoxing620@126.com.
  • Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China. Electronic address: yanglei_19940831@163…
  • Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China; Department of Chemistry, Sungkyunkwan Un…

Förderung

  • Shandong Province Natural Science Foundation
  • National Natural Science Foundation of China

Zitieren

APA

Jia, D., Hua, Y., Wu, T., Ren, X., Gao, X., Yang, L., & Wei, Q. (2025). Facile preparation of iridium-based AIE polymer dots for sensitive electrochemiluminescence immunoassay of CD44 protein. Analytica Chimica Acta, 1341, 343639. https://doi.org/10.1016/j.aca.2025.343639

Vancouver

Jia D, Hua Y, Wu T, Ren X, Gao X, Yang L, et al. Facile preparation of iridium-based AIE polymer dots for sensitive electrochemiluminescence immunoassay of CD44 protein. Analytica Chimica Acta. 2025;1341:343639. doi:10.1016/j.aca.2025.343639

BibTeX
@article{Jia2025,
  author = {Jia, Dehao and Hua, Yunhui and Wu, Tingting and Ren, Xiang and Gao, Xing and Yang, Lei and Wei, Qin},
  title = {Facile preparation of iridium-based AIE polymer dots for sensitive electrochemiluminescence immunoassay of CD44 protein},
  journal = {Analytica Chimica Acta},
  year = {2025},
  volume = {1341},
  pages = {343639},
  doi = {10.1016/j.aca.2025.343639}
}
Kostenlos starten →