EUVIMEDEUVIMED entdecken
Crossref

Magnetic relaxation switch biosensor for detection of Vibrio parahaemolyticus based on photocleavable hydrogel

Le Chen, Dongyu Zhang, Fan Yang, Xizhi Shi, Xiaohua Jiang, Tingting Hao, Qingqing Zhang, Yufang Hu, Sui Wang, Zhiyong Guo

Analytica Chimica Acta · 2025-01 · 1336 · 343516

DOI: 10.1016/j.aca.2024.343516 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2025-01. Verfasst von Le Chen und 9 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products, School of Material Science and Chemical Eng…. Hauptthemen laut MEDLINE: Vibrio parahaemolyticus, Biosensing Techniques, Hydrogels. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 52 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Key Research and Development Program of Zhejiang Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Foodborne pathogens, particularly Vibrio parahaemolyticus (VP) found in seafood, pose significant health risks, including abdominal pain, nausea, and even death. Rapid, accurate, and sensitive detection of these pathogens is crucial for food safety and public health. However, existing detection methods often require complex sample pretreatment, which limits their practical application. This study aims to overcome these limitations by developing a label-free magnetic relaxation switch (MRS) biosensor for the detection of VP, utilizing a photocleavable sol-gel phase transition system for improved efficiency and accuracy. RESULTS: In this work, a tag-free magnetic relaxation switch (MRS) biosensor was designed for the detection of Vibrio parahaemolyticus (VP), based on a photocleavable sol-gel phase transition system. A large amount of lithium acyl hypophosphite (LAP), gold nanoparticles (AuNPs), and single-stranded DNA (ssDNA) loaded on the surface of Ti3C2Tx MXene acted as the signal unit LAP-MXene@AuNPs-ssDNA. The pipette tip served as a reaction vessel, and when VP was present, Apt specifically captured VP and released the signal units. The released signal units were then injected into the low-field nuclear magnetic resonance (LF-NMR) test solution, a gel formed by crosslinking of disulfide bonds. The gel was cleaved by LAPs on the signal units under ultraviolet (UV) irradiation, triggering a gel-sol phase transition, which increased transverse relaxation time (T2), thus enabling the detection of VP. Under the optimal experimental conditions, the linear range and detection limit for VP were 102 ∼ 108 CFU/mL and 10 CFU/mL, respectively. SIGNIFICANCE AND NOVELTY: The simplified biometric identification process in the pipette tip reduces errors from multiple sample transfers, enhancing efficiency. The use of photocleavable hydrogel for signal output eliminates issues associated with magnetic material aggregation, significantly improving detection precision. The assay is of good selectivity, stability reproducibility, and convenience, having a broad application prospect in the rapid detection of pathogenic bacteria in the field.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Vibrio parahaemolyticusBiosensing TechniquesHydrogelsGoldPhotochemical ProcessesMetal NanoparticlesLimit of DetectionDNA, Single-Stranded

Stichwörter der Autor:innen

Gel-sol phase transitionLow-field nuclear magnetic resonanceMagnetic relaxation switchPhotocleavageVibrio parahaemolyticus

Substanzen

HydrogelsGoldDNA, Single-Stranded

Autor:innen und Institutionen

  • State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products, School of Material Science and Chemical Engineering, Ningbo University, Ningbo, 315211, PR China.
  • State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products, School of Marine Sciences, Ningbo University, Ningbo, 315211, PR China. Electronic address: shixizhi@nbu.edu.cn.
  • School of Undergraduate Education, Shenzhen Polytechnic University, Shenzhen, 518055, PR China. Electronic address: jiangxiaohua@szpu.edu.cn.
  • State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products, School of Material Science and Chemical Engineering, Ningbo University, Ningbo, 315211, PR China. Electronic addr…

Förderung

  • National Natural Science Foundation of China
  • Key Research and Development Program of Zhejiang Province

Zitieren

APA

Chen, L., Zhang, D., Yang, F., Shi, X., Jiang, X., Hao, T., Zhang, Q., Hu, Y., Wang, S., & Guo, Z. (2025). Magnetic relaxation switch biosensor for detection of Vibrio parahaemolyticus based on photocleavable hydrogel. Analytica Chimica Acta, 1336, 343516. https://doi.org/10.1016/j.aca.2024.343516

Vancouver

Chen L, Zhang D, Yang F, Shi X, Jiang X, Hao T, et al. Magnetic relaxation switch biosensor for detection of Vibrio parahaemolyticus based on photocleavable hydrogel. Analytica Chimica Acta. 2025;1336:343516. doi:10.1016/j.aca.2024.343516

BibTeX
@article{Chen2025,
  author = {Chen, Le and Zhang, Dongyu and Yang, Fan and Shi, Xizhi and Jiang, Xiaohua and Hao, Tingting and Zhang, Qingqing and Hu, Yufang and Wang, Sui and Guo, Zhiyong},
  title = {Magnetic relaxation switch biosensor for detection of Vibrio parahaemolyticus based on photocleavable hydrogel},
  journal = {Analytica Chimica Acta},
  year = {2025},
  volume = {1336},
  pages = {343516},
  doi = {10.1016/j.aca.2024.343516}
}
Kostenlos starten →