EUVIMEDEUVIMED entdecken
Validierungsstudie

Quantification of five antineoplastic agents in swab samples using UPLC-ESI-MS/MS: Method development and validation

Eline Verscheure, Matteo Creta, Katrien Poels, Jeroen Vanoirbeek, Manosij Ghosh, Lode Godderis

Analytica Chimica Acta · 2025

DOI: 10.1016/j.aca.2024.343492 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Analytica Chimica Acta, 2025. Verfasst von Eline Verscheure und 5 weiteren Autor:innen. Beteiligte Einrichtung: Centre for Environment and Health, Department of Public Health and Primary Care, KU Leuven, Leuven, Belgium. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Antineoplastic Agents, Spectrometry, Mass, Electrospray Ionization. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 21 Literaturangaben. Gefördert von: Research Foundation Flanders.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Antineoplastic agents are hazardous drugs used in cancer treatment and consequently can be present at the workplace (e.g. hospital), but also in a home-setting in case of treatment at home. Given the serious health effects, it is important to monitor environmental contamination on a regular base. As currently, no method allows for simultaneous quantification of cyclophosphamide, etoposide, mitomycin C, imatinib and 5-fluorouracil, we developed and validated a method for simultaneous quantification of multiple antineoplastic agents in swab samples. RESULTS: Sample collection was optimised and samples were extracted using solely an extraction solvent (water or water/acetonitrile), shaking and sonicating. Ultra performance liquid chromatography coupled to tandem mass spectrometry with electrospray ionisation was used for detection of the compounds. Selectivity, linearity, sensitivity, precision and accuracy were determined. The LLOQs were 0.3 ng/swab (cyclophosphamide, mitomycin C), 1 ng/swab (etoposide) and 5 ng/swab (imatinib, 5-fluorouracil). After a spill, quantifiable concentrations of antineoplastic agents could be measured in swabs using the developed methods. After cleaning, all concentrations fell below the LLOQ. SIGNIFICANCE: Two methods allowing for safe collection, rapid preparation and sensitive quantification were developed and can be applied in the field to measure environmental contamination. One for simultaneous quantification of cyclophosphamide, etoposide, mitomycin C and imatinib, one for quantification of 5-fluorouracil.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tandem Mass SpectrometryAntineoplastic AgentsSpectrometry, Mass, Electrospray IonizationChromatography, High Pressure LiquidImatinib MesylateFluorouracilCyclophosphamideEtoposideHumansMitomycin

Stichwörter der Autor:innen

Anticancer drugAntineoplastic agentsChemical contaminationEnvironmental monitoringLiquid chromatographyMass spectrometrySwabsTrace analysis

Substanzen

Antineoplastic AgentsImatinib MesylateFluorouracilCyclophosphamideEtoposideMitomycin

Autor:innen und Institutionen

  • Centre for Environment and Health, Department of Public Health and Primary Care, KU Leuven, Leuven, Belgium.
  • Centre for Environment and Health, Department of Public Health and Primary Care, KU Leuven, Leuven, Belgium; Idewe, External Service for Prevention and Protection at Work, Heverlee, Belgium. Electronic address: lode.god…

Förderung

  • Research Foundation Flanders

Zitieren

APA

Verscheure, E., Creta, M., Poels, K., Vanoirbeek, J., Ghosh, M., & Godderis, L. (2025). Quantification of five antineoplastic agents in swab samples using UPLC-ESI-MS/MS: Method development and validation. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2024.343492

Vancouver

Verscheure E, Creta M, Poels K, Vanoirbeek J, Ghosh M, Godderis L. Quantification of five antineoplastic agents in swab samples using UPLC-ESI-MS/MS: Method development and validation. Analytica Chimica Acta. 2025. doi:10.1016/j.aca.2024.343492

BibTeX
@article{Verscheure2025,
  author = {Verscheure, Eline and Creta, Matteo and Poels, Katrien and Vanoirbeek, Jeroen and Ghosh, Manosij and Godderis, Lode},
  title = {Quantification of five antineoplastic agents in swab samples using UPLC-ESI-MS/MS: Method development and validation},
  journal = {Analytica Chimica Acta},
  year = {2025},
  doi = {10.1016/j.aca.2024.343492}
}
Kostenlos starten →