EUVIMEDEUVIMED entdecken
Crossref

Electrochemistry–glucosemeter–smartphone integrated multi-mode biosensor for accurate detection of aflatoxin B1

Zhiguang Suo, Tao Lu, Jiahui Liu, Jiayi Li, Li Wang, Yong Liu, Min Wei

Analytica Chimica Acta · 2025-01 · 1333 · 343398

DOI: 10.1016/j.aca.2024.343398 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2025-01. Verfasst von Zhiguang Suo und 6 weiteren Autor:innen. Beteiligte Einrichtung: College of Food Science and Technology, Henan Key Laboratory of Cereal and Oil Food Safety Inspection and Control, Henan University of Technology, Zh…. Hauptthemen laut MEDLINE: Aflatoxin B1, Biosensing Techniques, Smartphone, Electrochemical Techniques. Die Arbeit wurde bisher 35-mal zitiert (Crossref) und nennt 45 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Aflatoxin B1 (AFB1) is a widely distributed toxic contaminant in food and poses a serious threat to public health. Therefore, an accurate, simple, cost-effective and on-site assay method is needed for sensitive detection of AFB1. Aptamer shows great potential in the construction of biosensor due to its high specificity and affinity. Multimodal biosensor based on aptamer is highly suitable for the analysis of AFB1 under complex conditions. And the detection results in different modes can be verified with each other, which greatly improves the accuracy of AFB1 detection. RESULTS: Herein, accurate detection of AFB1 was achieved through the development of a multi-mode biosensor integrating electrochemistry, glucosemeter and smartphone-based colorimetric quantification. Streptavidin-Cu3(PO4)2 hybrid nanoflowers (SA-Cu3(PO4)2 HNFs) were synthesised and then conjugated with biotinylated invertase as a signal probe. The electrochemical signal was achieved via intrinsic redox activity. Simultaneously, sucrose could be converted to glucose by the action of invertase, which can cause changes in the glucosemeter signal as well as in the colour of urine glucose test strips. The glucosemeter could complete the signal response in 7 s, and the urine glucose test strips could complete the colour development in 30 s. The detection range of AFB1 by this system in electrochemical mode is 0.001-100 ng/mL, and in glucosemeter mode and smartphone mode is 0.01-50 ng/mL. The limits of detection were 0.49 pg/mL in electrochemistry mode, 5.4 pg/mL in glucosemeter mode and 3.7 pg/mL in smartphone mode. SIGNIFICANCE: The successful construction of this multi-mode biosensor demonstrates the advantages of multifunctional nanomaterials and mobile technology. Rapid and accurate detection of AFB1 is achieved through the integration of electrochemistry, glucosemeter and smartphone-based colorimetric quantification. And this biosensor provides a novel detection platform that combines sensitivity, accuracy, affordability and portability for rapid on-site food safety screening.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aflatoxin B1Biosensing TechniquesSmartphoneElectrochemical TechniquesColorimetryLimit of DetectionAptamers, NucleotideGlucoseFood Contamination

Stichwörter der Autor:innen

ElectrochemistryGlucosemeterMulti-mode biosensorOrganic–inorganic hybrid nanoflowersSmartphone

Substanzen

Aflatoxin B1Aptamers, NucleotideGlucose

Autor:innen und Institutionen

  • College of Food Science and Technology, Henan Key Laboratory of Cereal and Oil Food Safety Inspection and Control, Henan University of Technology, Zhengzhou, 450001, China. Electronic address: zg_suo@163.com.
  • College of Food Science and Technology, Henan Key Laboratory of Cereal and Oil Food Safety Inspection and Control, Henan University of Technology, Zhengzhou, 450001, China.
  • College of Food Science and Technology, Henan Key Laboratory of Cereal and Oil Food Safety Inspection and Control, Henan University of Technology, Zhengzhou, 450001, China; Sinograin Anyang Depot Ltd.Company, Anyang, 45…
  • Sinograin Anyang Depot Ltd.Company, Anyang, 455000, China.
  • College of Chemistry and Chemical Engineering, Henan University, Kaifeng, 475004, China.
  • College of Food Science and Technology, Henan Key Laboratory of Cereal and Oil Food Safety Inspection and Control, Henan University of Technology, Zhengzhou, 450001, China. Electronic address: wei_min80@163.com.

Zitieren

APA

Suo, Z., Lu, T., Liu, J., Li, J., Wang, L., Liu, Y., & Wei, M. (2025). Electrochemistry–glucosemeter–smartphone integrated multi-mode biosensor for accurate detection of aflatoxin B1. Analytica Chimica Acta, 1333, 343398. https://doi.org/10.1016/j.aca.2024.343398

Vancouver

Suo Z, Lu T, Liu J, Li J, Wang L, Liu Y, et al. Electrochemistry–glucosemeter–smartphone integrated multi-mode biosensor for accurate detection of aflatoxin B1. Analytica Chimica Acta. 2025;1333:343398. doi:10.1016/j.aca.2024.343398

BibTeX
@article{Suo2025,
  author = {Suo, Zhiguang and Lu, Tao and Liu, Jiahui and Li, Jiayi and Wang, Li and Liu, Yong and Wei, Min},
  title = {Electrochemistry–glucosemeter–smartphone integrated multi-mode biosensor for accurate detection of aflatoxin B1},
  journal = {Analytica Chimica Acta},
  year = {2025},
  volume = {1333},
  pages = {343398},
  doi = {10.1016/j.aca.2024.343398}
}
Kostenlos starten →