Raw data and noise in spectrophotometry
Analytica Chimica Acta · 2025-01 · 1333 · 343393
DOI: 10.1016/j.aca.2024.343393 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2025-01. Verfasst von Bruna Falgueras Vallbona und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry and Forensics, School of Science and Technology, Nottingham Trent University, Nottingham, NG11 8NS, United Kingdom. Electroni…. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Nottingham.
Abstract (Originalsprache)
BACKGROUND: Spectrophotometers are ubiquitous in chemical and biological science; however, their precision limits are under-appreciated. Rules-of-thumb and IUPAC referenced guidance restricting absorbance ranges to minimize uncertainty are based on historically important instruments which are no longer as widely used. Advances over the last half-century changed most "raw" data from absorbance and transmittance values directly produced in analog electronics to digitized intensities. The latter are rarely provided in favour of digitally transformed derived data. Assessment of spectrophotometer limitations using digitized intensities would be straightforward with mean-variance analysis. However, in their absence, derived data evaluated at scale allows efficient characterisation of modern spectrophotometers. RESULTS: This study analyses signals when I and I0 are not available and only absorbance or transmittance are obtained. Current IUPAC referenced guidance indicates that absorbance should be limited between 0.1 and 1.0 a.u. with optimal performance (minimum relative standard deviation (RSD)) at 0.43 a.u. or 0.86 a.u. depending on the type of limiting noise. We characterised noise in UV-Vis spectrophotometers using three methods and report optimality spectra for the first time. We found the instruments were not Poisson optimal and best RSDs were sometimes above 1.0 a.u. We could find no evidence justifying guidance restricting absorbance to between 0.1 and 1.0 a.u. Measured RSD and light intensity are more important than absorbance values for assuring good quality measurements. However, estimating light intensity is a difficult inverse problem when I and I0 are not available, and the tested commercial instruments did not provide these. SIGNIFICANCE: Based on this work, classical theories are insufficient to describe spectrophotometers accurately. Furthermore, we urge IUPAC to modernise the references in its Gold Book and press instrument makers to improve data transparency. These steps are crucial to use spectrophotometers optimally.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Chemistry and Forensics, School of Science and Technology, Nottingham Trent University, Nottingham, NG11 8NS, United Kingdom. Electronic address: N0830629@my.ntu.ac.uk.
- Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijglaan 281, B-9000, Ghent, Belgium.
- Department of Physics and Mathematics, School of Science and Technology, Nottingham Trent University, Nottingham, NG11 8NS, United Kingdom.
- GH and Q Services Limited, West Studios, Sheffield Road, Chesterfield, S41 7LL, United Kingdom; College of Science and Engineering, University of Derby, Markeaton Street, Derby, DE22 3AW, United Kingdom.
Förderung
- University of Nottingham
Zitieren
APA
Falgueras Vallbona, B., Kajtazi, A., Shahtahmassebi, G., & Hanley, Q. S. (2025). Raw data and noise in spectrophotometry. Analytica Chimica Acta, 1333, 343393. https://doi.org/10.1016/j.aca.2024.343393
Vancouver
Falgueras Vallbona B, Kajtazi A, Shahtahmassebi G, Hanley QS. Raw data and noise in spectrophotometry. Analytica Chimica Acta. 2025;1333:343393. doi:10.1016/j.aca.2024.343393
BibTeX
@article{FalguerasVallbona2025,
author = {Falgueras Vallbona, Bruna and Kajtazi, Ardiana and Shahtahmassebi, Golnaz and Hanley, Quentin S},
title = {Raw data and noise in spectrophotometry},
journal = {Analytica Chimica Acta},
year = {2025},
volume = {1333},
pages = {343393},
doi = {10.1016/j.aca.2024.343393}
}