Microcolumn and coelution hydration of oil seal blood spot for efficient screening of newborn α-thalassemia via chip isoelectric focusing
Analytica Chimica Acta · 2024-12 · 1331 · 343342
DOI: 10.1016/j.aca.2024.343342 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2024-12. Verfasst von Genhan Zha und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Instrument Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shangha…. Hauptthemen laut MEDLINE: alpha-Thalassemia, Isoelectric Focusing, Neonatal Screening. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 31 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Ministry of Science and Technology of the People's Republic of China, Shanghai Jiao Tong University.
Abstract (Originalsprache)
BACKGROUND: The global prevalence of α-thalassemia necessitates effective newborn screening strategies due to its severe clinical consequences. Traditional methods such as liquid chromatography (LC), capillary electrophoresis (CE), and isoelectric focusing (IEF) face limitations, including low separation efficiency, poor sensitivity for detecting Hb Bart's, and time-intensive operations, particularly with dried blood spots (DBS). These limitations hinder timely and accurate screening. This study addresses the need for a more efficient, sensitive, and rapid method for detecting Hb Bart's in newborns. RESULTS: We enhanced IEF separation and sensitivity by designing a microfluidic IEF (mIEF) system with shortened columns and employing a coelution sample loading technique using oil-sealed blood spots for rapid sample pretreatment. Our experiments demonstrated significant improvements: the total analysis time was reduced from 1110 min (IPG IEF) and 46 min (LC) per batch to 36 min per batch. For individual samples, the focusing time decreased from 6 min (previous mIEF) to 3 min, with the microcolumn length shortened by 50 %, from 30 mm to 15 mm. The developed method showed excellent consistency with clinical Bart's detection and PCR diagnosis, achieving 100 % sensitivity and 98 % specificity for α-thalassemia screening. SIGNIFICANCE AND NOVELTY: Our novel mIEF method provides an efficient, sensitive, and rapid tool for screening newborns for α-thalassemia. This advancement addresses the limitations of traditional techniques, improving early diagnosis and intervention strategies and ultimately enhancing health outcomes for at-risk newborns.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Instrument Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, 200240, PR China.
- NHC Key Laboratory of Thalassemia Medicine, Key Laboratory of Thalassemia Medicine, Chinese Academy of Medical Sciences, Guangxi Key Laboratory of Thalassemia Research, Guangxi Medical University, Nanning, 530021, PR Ch…
- Department of Instrument Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, 200240, PR China; School of Physics and Astronomy, Shanghai Jiao To…
- Department of Instrument Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, 200240, PR China; NHC Key Laboratory of Thalassemia Medicine, Key L…
- School of Physics and Astronomy, Shanghai Jiao Tong University, Shanghai, 200240, PR China.
- Department of Instrument Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, 200240, PR China. Electronic address: cping62@hotmail.com.
Förderung
- National Natural Science Foundation of China
- Ministry of Science and Technology of the People's Republic of China
- Shanghai Jiao Tong University
- Specific Research Project of Guangxi for Research Bases and Talents
Zitieren
APA
Zha, G., Xiao, X., Tian, Y., Zhu, H., Chen, P., Zhang, Q., Yu, C., Li, H., Wang, Y., & Cao, C. (2024). Microcolumn and coelution hydration of oil seal blood spot for efficient screening of newborn α-thalassemia via chip isoelectric focusing. Analytica Chimica Acta, 1331, 343342. https://doi.org/10.1016/j.aca.2024.343342
Vancouver
Zha G, Xiao X, Tian Y, Zhu H, Chen P, Zhang Q, et al. Microcolumn and coelution hydration of oil seal blood spot for efficient screening of newborn α-thalassemia via chip isoelectric focusing. Analytica Chimica Acta. 2024;1331:343342. doi:10.1016/j.aca.2024.343342
BibTeX
@article{Zha2024,
author = {Zha, Genhan and Xiao, Xuan and Tian, Youli and Zhu, Hengying and Chen, Ping and Zhang, Qiang and Yu, Changjie and Li, Honggen and Wang, Yuxing and Cao, Chengxi},
title = {Microcolumn and coelution hydration of oil seal blood spot for efficient screening of newborn α-thalassemia via chip isoelectric focusing},
journal = {Analytica Chimica Acta},
year = {2024},
volume = {1331},
pages = {343342},
doi = {10.1016/j.aca.2024.343342}
}
EUVIMED