A ZnO-nanorod/PEDOT:PSS nanocomposite functionalized bridge-like membrane type nanomechanical sensing device for ultrasensitive blood lead detection
Analytica Chimica Acta · 2024
DOI: 10.1016/j.aca.2024.343317 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2024. Verfasst von Yi-Kuang Yen und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, National Taipei University of Technology, Taipei, Taiwan; Department of Intelligent Automation Engineering, Nat…. Hauptthemen laut MEDLINE: Lead, Zinc Oxide, Nanocomposites, Polymers. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 62 Literaturangaben. Gefördert von: National Taipei University of Technology, Chang Gung Memorial Hospital, Linkou Chang Gung Memorial Hospital.
Abstract (Originalsprache)
Lead (Pb) ion detection poses a critical problem, particularly in environmental monitoring, industrial operations, and public health, especially for young children and expecting women. Determining lead levels in blood early on is essential to minimizing the long-term consequences of lead exposure. Several sophisticated detection instruments, such as mass spectrometers which perform with high sensitivity, specificity and accuracy, but require a lab-based setting, multi-step sample preparation, expensive payment and professional operation. It is evident that a highly sensitive, portable, low-cost, quick sample-to-result, blood lead detection device that can be tested at the point-of-care is necessary. Consequently, we developed a unique ZnO/PEDOT:PSS nanocomposite layer integrated with a CMOS MEMS-based bridge-like membrane-type (BM) nanomechanical sensor for detecting lead levels in blood. PEDOT:PSS was combined with ZnO nanorods to increase lead ion binding. The sensor responds seven times better to lead ions using nanorods in the detecting layer. A linear resistance change rate response was found from 0.005 to 10 ppm, with the limit of detection (LOD) of 0.12 ppb. Similarly, our BM nanomechanical sensor can correctly assess Pb2+ in human serum with recovery rates of 86.25-150 %. Measurements of human blood samples from patients with varying lead ion concentrations validated by the standard AAS show a good linear connection with the BM nanomechanical sensors' concentration, with a regression coefficient of 0.92. This describes the first micromachined nanoachanical sensing system for detection of Pb2+ in only 5 μL of human serum sample. The device achieves a time-to-result of less than 10 min. The system is designed to be very sensitive and offers affordable, disposable sensing chips together with a portable signal acquisition platform.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Mechanical Engineering, National Taipei University of Technology, Taipei, Taiwan; Department of Intelligent Automation Engineering, National Taipei University of Technology, Taipei, Taiwan. Electronic addr…
- Department of Electronic Engineering, Chang-Gung University, Taoyuan City, Taiwan; Institute of Electro-Optical Engineering, Chang Gung University, Taoyuan City, Taiwan; Department of Neurosurgery, Chang Gung Memorial H…
- Cloud Enterprise Solutions Business Group, Foxconn, New Taipei City, Taiwan.
- Department of Nephrology, Clinical Poison Center, Chang Gung Memorial Hospital, Linkou, Taoyuan City, Taiwan; College of Medicine, Chang Gung University, Taoyuan City, Taiwan. Electronic address: m19570@cgmh.org.tw.
- Department of Mechanical Engineering, National Taipei University of Technology, Taipei, Taiwan.
- Winbond Electronics Corporation, Taichung City, Taiwan.
Förderung
- National Taipei University of Technology
- Chang Gung Memorial Hospital
- Linkou Chang Gung Memorial Hospital
Zitieren
APA
Yen, Y. K., Yang, C. M., Kao, C. T., Yen, T. H., Shanmugam, R., Chen, Y. L., & Lin, H. E. (2024). A ZnO-nanorod/PEDOT:PSS nanocomposite functionalized bridge-like membrane type nanomechanical sensing device for ultrasensitive blood lead detection. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2024.343317
Vancouver
Yen YK, Yang CM, Kao CT, Yen TH, Shanmugam R, Chen YL, et al. A ZnO-nanorod/PEDOT:PSS nanocomposite functionalized bridge-like membrane type nanomechanical sensing device for ultrasensitive blood lead detection. Analytica Chimica Acta. 2024. doi:10.1016/j.aca.2024.343317
BibTeX
@article{Yen2024,
author = {Yen, Yi-Kuang and Yang, Chia-Ming and Kao, Chen-Ting and Yen, Tzung-Hai and Shanmugam, Ragurethinam and Chen, Yan-Lin and Lin, Hwai-En},
title = {A ZnO-nanorod/PEDOT:PSS nanocomposite functionalized bridge-like membrane type nanomechanical sensing device for ultrasensitive blood lead detection},
journal = {Analytica Chimica Acta},
year = {2024},
doi = {10.1016/j.aca.2024.343317}
}
EUVIMED