Lab-on-a-chip paper-based electrochemically assisted solid-phase microextraction and ion selective sensor for determination of naproxen in biological fluid samples
Analytica Chimica Acta · 2024
DOI: 10.1016/j.aca.2024.343275 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2024. Verfasst von Hanieh Haghgouei und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Faculty of Basic Sciences, Tarbiat Modares University, P.O. Box 14115-175, Tehran, Iran. Hauptthemen laut MEDLINE: Lab-On-A-Chip Devices, Electrochemistry, Solid Phase Microextraction, Naproxen. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 42 Literaturangaben. Gefördert von: Tarbiat Modares University, Iran National Science Foundation.
Abstract (Originalsprache)
BACKGROUND: The integration of paper-based analytical devices with lab-on-a-chip technology has opened up new possibilities for miniaturized, rapid, low cost and portable diagnostic testing in resource limited settings. This work introduces an integrated lab-on-a-chip platform coupling paper-based analytical devices (LOC-PADs) for dual usage: electrochemically controlled solid-phase microextraction (EC-SPME) and determination of naproxen (NAP) by potentiometric ion-selective electrode (ISE) in biological samples. RESULTS: Conductive papers were successfully fabricated by a chemical procedure. Thereupon, a conducting molecularly imprinted polymer (CMIP) film based on PPy and an anionic model drug (NAP) as a template were applied to the conductive paper substrate via electrochemical methods. A microfluidic chip device was employed to assess the analytical performance of the fabricated paper-based CMIP. The designed chip is divided into two parts with a microfluidic channel between them. The first chamber is an extraction zone for EC-SPME of NAP by using the CMIP paper as a selective sorbent. The second chamber is the detection zone and consists of a paper-based NAP ion selective sensor for potentiometric detection of drug. The analytical process was investigated and optimized for each chamber. Remarkable selectivity towards NAP was achieved in the concentration range from 4.0 × 10-7 to 1.0 × 10-2 mol L-1 with determination coefficient (R2 = 0.99) and the limit of detection (LOD) was 2.0 × 10-7 mol L-1. Anionic Nernstian compliance was gained -58.5 ± 0.5 mV decade-1, and response time in the detection step was 7s for ISE. Satisfactory spiking recovery values within the acceptable range of 90-110 % with RSDs ≤7 % were achieved for the analysis of real samples with fully portable LOC device. SIGNIFICANCE: The LOC-PADs were favorably used for selective extraction and determination of NAP in serum and saliva samples, respectively. EC-SPME caused sample clean-up, reduced or eliminated different interferences and enhanced selective response of ISE as detection zone of device. Integration of EC-SPME and ISE in a single chip enabled easy and fast determination of trace amounts of NAP in limited real sample volumes, and fully portable advantages.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, Faculty of Basic Sciences, Tarbiat Modares University, P.O. Box 14115-175, Tehran, Iran.
- Department of Chemistry, Faculty of Basic Sciences, Tarbiat Modares University, P.O. Box 14115-175, Tehran, Iran. Electronic address: alizaden@modares.ac.ir.
Förderung
- Tarbiat Modares University
- Iran National Science Foundation
Zitieren
APA
Haghgouei, H., & Alizadeh, N. (2024). Lab-on-a-chip paper-based electrochemically assisted solid-phase microextraction and ion selective sensor for determination of naproxen in biological fluid samples. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2024.343275
Vancouver
Haghgouei H, Alizadeh N. Lab-on-a-chip paper-based electrochemically assisted solid-phase microextraction and ion selective sensor for determination of naproxen in biological fluid samples. Analytica Chimica Acta. 2024. doi:10.1016/j.aca.2024.343275
BibTeX
@article{Haghgouei2024,
author = {Haghgouei, Hanieh and Alizadeh, Naader},
title = {Lab-on-a-chip paper-based electrochemically assisted solid-phase microextraction and ion selective sensor for determination of naproxen in biological fluid samples},
journal = {Analytica Chimica Acta},
year = {2024},
doi = {10.1016/j.aca.2024.343275}
}
EUVIMED