Electrochemical detection of folic acid in food extracts using molecularly imprinted polyacrylonitrile imbued graphite electrode
Analytica Chimica Acta · 2024-10 · 1325 · 343120
DOI: 10.1016/j.aca.2024.343120 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2024-10. Verfasst von Dipan Bandyopadhyay und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Instrumentation and Electronics Engineering, Jadavpur University, Kolkata, 700106, India. Hauptthemen laut MEDLINE: Graphite, Electrodes, Acrylic Resins, Electrochemical Techniques. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 47 Literaturangaben. Gefördert von: CSIR – Indian Institute of Chemical Biology, Jadavpur University.
Abstract (Originalsprache)
The present study elucidates the effectiveness of a molecularly imprinted polyacrylonitrile-imbued graphite-base electrode (MAN@G) for the selective detection of folic acid (FA) in food samples. The prime objective of the recognition and quantification of vitamin compounds like FA is the overall quality assessment of vegetables and fruits. The cost-effective, reproducible, and durable MAN@G electrode has been fabricated using acrylonitrile (AN) as the monomer and FA as the template over graphite-base. The characterization of the synthesized MAN@G electrode material has been accomplished by utilizing UV-visible (UV-vis) spectroscopy and scanning electron microscopy (SEM). A tri-electrode system based on differential pulse voltammetry (DPV) and cyclic voltammetry (CV) techniques was employed to explore the analytical performance of the synthesized electrode. Rigorous analyses divulged that a widespread linearity window could be exhibited by the electrode under an optimized experimental environment, ranging from 20 μM to 400 μM concentrations with an acceptable lower limit of detection (LOD) and limit of quantification (LOQ) of 18 nM, and 60 nM respectively. Additionally, this electrode exhibits high reproducibility, good stability, and high repeatability, with RSD values of 1.72 %, 1.32 %, and 1.19 %, respectively. The detection efficacy of the proposed electrode has been further examined in food extracts, namely orange, spinach, papaya, soybean, and cooked rice, which endorsed high accuracy compared to the high-performance liquid chromatography (HPLC) method. Moreover, the statistical results obtained from the t-test analysis were also satisfactory for the FA concentrations present in those five samples.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Instrumentation and Electronics Engineering, Jadavpur University, Kolkata, 700106, India.
- University of Engineering and Management, Kolkata, 700160, India.
- Department of Electronics and Communication Engineering, Silicon Institute of Technology, Bhubaneswar, Odisha, 751024, India.
- Department of Instrumentation and Electronics Engineering, Jadavpur University, Kolkata, 700106, India. Electronic address: rbanerjee75@gmail.com.
Förderung
- CSIR – Indian Institute of Chemical Biology
- Jadavpur University
Zitieren
APA
Bandyopadhyay, D., Nag, S., Das, D., & Banerjee Roy, R. (2024). Electrochemical detection of folic acid in food extracts using molecularly imprinted polyacrylonitrile imbued graphite electrode. Analytica Chimica Acta, 1325, 343120. https://doi.org/10.1016/j.aca.2024.343120
Vancouver
Bandyopadhyay D, Nag S, Das D, Banerjee Roy R. Electrochemical detection of folic acid in food extracts using molecularly imprinted polyacrylonitrile imbued graphite electrode. Analytica Chimica Acta. 2024;1325:343120. doi:10.1016/j.aca.2024.343120
BibTeX
@article{Bandyopadhyay2024,
author = {Bandyopadhyay, Dipan and Nag, Shreya and Das, Debangana and Banerjee Roy, Runu},
title = {Electrochemical detection of folic acid in food extracts using molecularly imprinted polyacrylonitrile imbued graphite electrode},
journal = {Analytica Chimica Acta},
year = {2024},
volume = {1325},
pages = {343120},
doi = {10.1016/j.aca.2024.343120}
}
EUVIMED