Colorimetric sensors constructed with one dimensional PtNi nanowire and Pt nanowire nanozymes for Hg2+ detection
Analytica Chimica Acta · 2024-09 · 1321 · 343039
DOI: 10.1016/j.aca.2024.343039 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2024-09. Verfasst von Jingyuan Guo und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Capital Normal University, Beijing, 100048, China. Hauptthemen laut MEDLINE: Colorimetry, Mercury, Platinum, Nanowires. Die Arbeit wurde bisher 30-mal zitiert (Crossref) und nennt 40 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: In recent years, environmental pollution has attracted widespread global attention. Among them, environmental problems caused by heavy metal pollution pose a serious threat to human health and ecosystems. Mercury is a common heavy metal pollutant with high toxicity and wide distribution. Excessive intake of Hg2+ can cause permanent and severe damage to the nervous system, respiratory system, and kidneys in the human body. Therefore, developing both accurate and fast detection methods for Hg2+ is of great significance. RESULTS: A sensitive Hg2+ colorimetric sensor is designed based on PtNi nanowires (NWs) and Pt NWs with peroxidase-mimetic activity. PtNi NWs and Pt NWs catalyze the reaction of 3,3', 5,5'-tetramethylbenzidine (TMB) with hydrogen peroxide (H2O2) to produce blue oxidized TMB (oxTMB). The specific interaction of Pt-Hg significantly inhibits the peroxidase-mimetic activity of PtNi NW and Pt NW nanozymes, resulting in a lighter blue color. It is worth noting that compared with specific activity (SA) of Pt NWs (3.31 U/mg), PtNi NWs own superior SA (10.43 U/mg), which inevitably leads to a wider linear range of Hg2+ analysis (1 nM-200 μM) and a lower detection limit (0.6748 nM) for PtNi NWs-based colorimetric sensor, versus linear range (4 nM-5 μM) and LOD of 1.198 nM for Pt NWs-based colorimetric sensor, which are far below the Hg2+ threshold (10 nM) for drinking water set by the US Environmental Protection Agency. SIGNIFICANCE: The two nanozyme colorimetric sensors have been successfully used for the evaluation of Hg2+ in complex river water and tap water. Due to the advantages of simple operation, fast response, and high sensitivity, colorimetric sensors have broad application prospects in environmental monitoring.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, Capital Normal University, Beijing, 100048, China.
- School of Mathematics and Physics, Research Center for Environmental Monitoring and Sensor Design, Anqing Normal University, Anqing, 246133, China. Electronic address: yumin_leng@126.com.
- Department of Chemistry, Capital Normal University, Beijing, 100048, China. Electronic address: wangguo@cnu.edu.cn.
- Department of Chemistry, Capital Normal University, Beijing, 100048, China. Electronic address: czb979216@sina.com.
Zitieren
APA
Guo, J., Dong, C., Zhang, X., Liu, Y., Leng, Y., Wang, G., & Chen, Z. (2024). Colorimetric sensors constructed with one dimensional PtNi nanowire and Pt nanowire nanozymes for Hg2+ detection. Analytica Chimica Acta, 1321, 343039. https://doi.org/10.1016/j.aca.2024.343039
Vancouver
Guo J, Dong C, Zhang X, Liu Y, Leng Y, Wang G, et al. Colorimetric sensors constructed with one dimensional PtNi nanowire and Pt nanowire nanozymes for Hg2+ detection. Analytica Chimica Acta. 2024;1321:343039. doi:10.1016/j.aca.2024.343039
BibTeX
@article{Guo2024,
author = {Guo, Jingyuan and Dong, Chenxin and Zhang, Xiang and Liu, Yujia and Leng, Yumin and Wang, Guo and Chen, Zhengbo},
title = {Colorimetric sensors constructed with one dimensional PtNi nanowire and Pt nanowire nanozymes for Hg2+ detection},
journal = {Analytica Chimica Acta},
year = {2024},
volume = {1321},
pages = {343039},
doi = {10.1016/j.aca.2024.343039}
}
EUVIMED