EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

High-throughput, low-cost quantification of 11 therapeutic antibodies using caprylic acid precipitation and LC-MS/MS

Erik I Hallin, Trond Trætteberg Serkland, Tormod K Bjånes, Silje Skrede

Analytica Chimica Acta · 2024

DOI: 10.1016/j.aca.2024.342789 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2024. Verfasst von Erik I Hallin und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Biochemistry and Pharmacology, Haukeland University Hospital, Jonas Lies vei 87, N-5021, Bergen, Norway. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Caprylates. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Haukeland University Hospital.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Therapeutic drug monitoring of treatment with therapeutic antibodies is hampered by the application of a wide range of different methods in the quantification of serum levels. LC-MS based methods could significantly improve comparability of results from different laboratories, but such methods are often considered complicated and costly. We developed a method for LC-MS/MS based quantification of 11 therapeutic antibodies concomitantly measured in a single run, with emphasis on simplicity in sample preparation and low cost. RESULTS: After a single-step sample purification using caprylic acid precipitation to remove interfering proteins, the sample underwent proteolysis followed by LC-MS/MS analysis. Infliximab is used as internal standard for sample preparation while isotope-labeled signature peptides identified for each analyte are internal standards for the LC-MS/MS normalization. The method was validated according to recognized guidelines, and pipetting steps can be performed by automated liquid handling systems. The total precision of the method ranged between 2.7 and 7.3 % (5.1 % average) across the quantification range of 4-256 μg/ml for all 11 drugs, with an average accuracy of 96.3 %. Matrix effects were xamined in 55 individual patient samples instead of the recommended 6, and 147 individual patient samples were screened for interfering compounds. SIGNIFICANCE AND NOVELTY: Our method for simultaneous quantification of 11 t-mAb in human serum allows an unprecedented integration of robustness, speed and reduced complexity, which could pave the way for uniform use in research projects and clinical settings alike. In addition, the first LC-MS protocol for signature peptide-based quantification of durvalumab is described. This high throughput method can be readily adapted to a drug panel of choice.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tandem Mass SpectrometryCaprylatesHumansChemical PrecipitationChromatography, LiquidHigh-Throughput Screening AssaysAntibodies, MonoclonalLiquid Chromatography-Mass Spectrometry

Stichwörter der Autor:innen

Liquid chromatography-mass spectrometryMultiplexProtein precipitationQuantificationSignature peptideTherapeutic antibody

Substanzen

Caprylatesoctanoic acidAntibodies, Monoclonal

Autor:innen und Institutionen

  • Department of Medical Biochemistry and Pharmacology, Haukeland University Hospital, Jonas Lies vei 87, N-5021, Bergen, Norway.
  • Department of Medical Biochemistry and Pharmacology, Haukeland University Hospital, Jonas Lies vei 87, N-5021, Bergen, Norway; Department of Clinical Science, Faculty of Medicine, University of Bergen, Jonas Lies vei 87…

Förderung

  • Haukeland University Hospital

Zitieren

APA

Hallin, E. I., Serkland, T. T., Bjånes, T. K., & Skrede, S. (2024). High-throughput, low-cost quantification of 11 therapeutic antibodies using caprylic acid precipitation and LC-MS/MS. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2024.342789

Vancouver

Hallin EI, Serkland TT, Bjånes TK, Skrede S. High-throughput, low-cost quantification of 11 therapeutic antibodies using caprylic acid precipitation and LC-MS/MS. Analytica Chimica Acta. 2024. doi:10.1016/j.aca.2024.342789

BibTeX
@article{Hallin2024,
  author = {Hallin, Erik I and Serkland, Trond Trætteberg and Bjånes, Tormod K and Skrede, Silje},
  title = {High-throughput, low-cost quantification of 11 therapeutic antibodies using caprylic acid precipitation and LC-MS/MS},
  journal = {Analytica Chimica Acta},
  year = {2024},
  doi = {10.1016/j.aca.2024.342789}
}
Kostenlos starten →